Triple-Level Terminal Block

Terminal block with three vertically arranged connection levels for compact organization of multiple circuits or potentials.

A triple-level terminal block contains three electrical connection levels in one housing and can significantly increase installation density on a DIN rail.

Each level may be used for a separate electrical potential or may perform its own functional role.

The level configuration may include phase, neutral, protective, signal, and other specified functions.

Important design parameters include the number of potentials on each level, pitch between levels, number of connection points, and functional sequence of the levels.

Individual levels may be electrically independent, may have an integrated equipotential connection, or may support vertical bridging.

For identification of complex circuits, each level may have its own marking position.

Selection criteria include current and voltage of each level, permitted conductor sizes, functional configuration, horizontal and vertical bridging capabilities, and accessibility of all connection points.

Components in this subcategory

This subcategory includes triple-level terminal blocks with different combinations of functions and potentials across three levels.

Available parameters

Triple-Level Terminal Block

214 parameters
General6
Product Series

Commercial or technical designation of a manufacturer's product family sharing a common design and compatible characteristics.

Application

Range of tasks and systems for which the manufacturer recommends the component.

Intended Use

Primary function of the device and its intended use as defined by its design and the manufacturer's documentation.

Installation Location

Permissible installation location of the product: indoors, outdoors, in a technical area, or as part of equipment.

Installation Environment

Environmental conditions under which installation and operation of the product are permitted.

Orientation

Permissible spatial orientation of the component during installation and operation.

Dimensions5
Widthmm

External horizontal dimension of the product between its outermost lateral points.

Heightmm

External vertical dimension of the product from its lowest to its highest point.

Depthmm

External distance between the foremost and rearmost surfaces of the product.

Marking Area Widthmm

Usable width of the area provided by the design for application or installation of markings.

Marking Area Heightmm

Usable height of the area provided by the design for application or installation of markings.

Capacity and Layout10
Connection Point Count

Total number of electrical connection points provided by the product.

Connection Pitchmm

Centre-to-centre pitch between adjacent repeated electrical connection points or contacts.

Number of Electrical Potentials

Number of electrically independent potentials provided by the product design.

Connection Level Count

Number of vertically stacked or functionally distinct electrical connection levels.

Connections per Level

Number of electrical connection points provided on one connection level.

Number of Positions

Number of physical terminal positions provided by the product. This parameter is distinct from the number of connection points, potentials, and connection levels.

Marking Position Count

Number of separate positions provided on the product for installation or application of identification markings.

Potentials per Level

Number of electrically independent potentials provided on one level of a multi-level terminal block.

Connection Level Pitchmm

Centre-to-centre distance between adjacent vertically arranged electrical connection levels.

Level Function Configuration

Ordered functional configuration of the connection levels declared by the manufacturer, for example L/L, L/N, PE/L/N, or another specified combination.

Materials and Finish14
Color

Primary visually perceived colour of the product's external surface.

RAL Color

Designation of the product's primary surface colour according to the RAL colour system.

Electrically Insulating Material

Indicates whether the product's primary material has electrical insulating properties and is intended to electrically separate conductive parts.

Insulation Material

Primary electrical insulation material applied to or integrated with the conductive part of the product.

Insulation Thermal Class

Manufacturer-declared thermal class of the electrical insulation system or insulation material.

Insulating Material Group

Insulating material group used when evaluating creepage distances and insulation coordination.

Comparative Tracking IndexV

Comparative Tracking Index (CTI) of the insulating material, characterizing its resistance to formation of conductive tracks under specified test conditions.

Insulation Material Temperature Index°C

Manufacturer-declared temperature index of the insulating material.

Relative Temperature Index°C

Manufacturer-declared Relative Temperature Index (RTI) of the insulating material.

Current-Carrying Part Material

Primary material of the internal current-carrying part, bridge, busbar, or other conductive element of the product.

Current-Carrying Part Material Grade

Grade, alloy designation, or other declared material designation of the main current-carrying part.

Current-Carrying Part Plating

Metallic plating of the principal current-carrying part, different from its base material.

Clamping Element Material

Material of the mechanical clamping element, such as a screw, spring, pressure plate, or clamping cage.

Clamping Element Plating

Protective or functional metallic plating of the mechanical clamping element.

Mounting and Installation10
DIN Rail Type

Profile type of the DIN rail installed in the product or specified for compatible mounting.

DIN Rail Orientation

Spatial orientation of the DIN rail relative to the product in its intended installed position.

Mounting Type

Installation arrangement permitted by the product design, such as wall-mounted, flush-mounted, floor-mounted, or another specified mounting type.

Mounting Method

Method used to mechanically secure the product to a support, surface, or load-bearing structure.

Mounting Surface

Type of surface or supporting base to which the product may be fixed.

DIN Rail Mounting Supported

Indicates whether the design provides for mounting equipment on a DIN rail.

Direct Device Mounting Supported

Indicates whether equipment may be mounted directly to the mounting surface without an intermediate DIN rail.

Compatible DIN Rail Types

List of DIN rail profiles with which the product is mechanically compatible.

Tool-Free Mounting

Indicates whether the intended installation of the product can be carried out without tools.

End Clamp Required

Indicates whether a separate end clamp or end stop is required to mechanically secure the terminal block or terminal row on the mounting rail.

Electrical Parameters62
Supply Current Type

Type of electrical current for which the product's main supply circuit is intended.

Rated VoltageV

Voltage value assigned to the product by the manufacturer for specified application conditions and characteristics.

Rated AC VoltageV

Rated RMS value of alternating voltage assigned to the product by the manufacturer.

Rated DC VoltageV

Rated direct voltage assigned to the product by the manufacturer.

Rated Operational VoltageV

Operating-circuit voltage with reference to which the product's performance characteristics are specified.

Maximum Operating VoltageV

Maximum voltage at which continuous operation of the product is permitted under the conditions declared by the manufacturer.

Minimum Operating VoltageV

Minimum voltage at which the manufacturer guarantees the intended operating mode of the product.

Rated CurrentA

Current assigned to the product by the manufacturer for the declared operating and thermal conditions.

Maximum Rated CurrentA

Highest rated current permitted for the relevant version or configuration of the product.

Supported Conductor Material

Conductor materials for which the specified terminals and connection methods are designed.

Conductor Connection Type

Conductor connection methods supported by the specified terminals or connection elements.

Terminal Tightening TorqueNm

Tightening torque specified by the manufacturer for a screw or bolted terminal connection.

Rated Insulation VoltageV

Voltage with reference to which the product's insulation clearances and dielectric properties are specified.

Rated Impulse Withstand VoltagekV

Peak value of an impulse voltage of specified waveform that the product insulation must withstand without breakdown.

Dielectric Test VoltageV

Test voltage applied to verify the dielectric strength of the product insulation.

Minimum Insulation ResistanceMΩ

Minimum permissible insulation resistance between the specified electrically separated parts.

Overvoltage Category

Category characterizing the expected level of impulse overvoltages at the product's point of use.

Pollution Degree

Degree of pollution of the surrounding microenvironment considered when selecting insulation distances and product characteristics.

Insulation Type

Type of electrical insulation used, considered in terms of its protective function and construction.

Electrical Protection Class

Class of protection against electric shock determined by the product design and protective connection method.

Power Dissipation at Rated CurrentW

Thermal power loss of the product or current-carrying system at rated current.

Supported Conductor Class

Conductor construction classes permitted by the product's electrical connection system.

Maximum Main Conductors per Terminal

Maximum number of main-power-circuit conductors that may be connected simultaneously to one terminal.

Voltage Drop at Rated CurrentV

Manufacturer-declared voltage drop across the product, connection path or current-carrying element at rated current under the specified reference conditions.

Temperature Rise at Rated CurrentK

Manufacturer-declared temperature rise of the product above ambient temperature at rated current under the specified installation conditions.

Minimum Electrical Clearancemm

Minimum manufacturer-declared clearance through air between conductive parts at different electrical potentials.

Minimum Creepage Distancemm

Minimum manufacturer-declared creepage distance along an insulating surface between conductive parts at different electrical potentials.

Maximum Conductor Temperature°C

Maximum manufacturer-declared permissible temperature of the conductive part of the product in service.

Nominal Conductor Cross-Sectionmm²

Manufacturer-declared nominal conductor cross-section assigned to the relevant connection system.

Minimum Conductor Cross-Sectionmm²

Minimum conductor cross-section permitted by the connection system within its general conductor-size range.

Maximum Conductor Cross-Sectionmm²

Maximum conductor cross-section permitted by the connection system within its general conductor-size range.

Minimum Stripping Lengthmm

Minimum conductor stripping length specified by the manufacturer.

Maximum Stripping Lengthmm

Maximum conductor stripping length specified by the manufacturer.

Connection Contact ResistancemΩ

Declared electrical contact resistance of a connection point where one common value applies to equivalent connections.

Maximum Terminal Temperature RiseK

Maximum permissible temperature rise of a terminal or connection point under the declared test or operating conditions.

Maximum Load CurrentA

Maximum load current declared by the manufacturer for the specified conductor cross-section and operating conditions. This parameter is distinct from the overall rated current of the product.

Terminal Screw Thread

Thread designation of the screw used in the conductor clamping mechanism, for example M2.5, M3, M4, or another manufacturer-declared designation.

Minimum Rigid Conductor Cross-Sectionmm²

Minimum rigid conductor cross-section permitted by an electrically and mechanically equivalent connection point.

Maximum Rigid Conductor Cross-Sectionmm²

Maximum rigid conductor cross-section permitted by an electrically and mechanically equivalent connection point.

Minimum Flexible Conductor Cross-Sectionmm²

Minimum flexible conductor cross-section permitted by the relevant connection point.

Maximum Flexible Conductor Cross-Sectionmm²

Maximum flexible conductor cross-section permitted by the relevant connection point.

Minimum Ferrule Cross-Section without Sleevemm²

Minimum flexible conductor cross-section with a ferrule without an insulating plastic collar permitted by the relevant connection point.

Maximum Ferrule Cross-Section without Sleevemm²

Maximum flexible conductor cross-section with a ferrule without an insulating plastic collar permitted by the relevant connection point.

Minimum Ferrule Cross-Section with Sleevemm²

Minimum flexible conductor cross-section with a ferrule and insulating plastic collar permitted by the relevant connection point.

Maximum Ferrule Cross-Section with Sleevemm²

Maximum flexible conductor cross-section with a ferrule and insulating plastic collar permitted by the relevant connection point.

Minimum TWIN Ferrule Conductor Cross-Sectionmm²

Minimum cross-section of each of two conductors connected simultaneously using a TWIN ferrule.

Maximum TWIN Ferrule Conductor Cross-Sectionmm²

Maximum cross-section of each of two conductors connected simultaneously using a TWIN ferrule.

Minimum Ultrasound-Compressed Conductor Cross-Sectionmm²

Minimum flexible conductor cross-section with ultrasonically compacted strands permitted by the relevant connection point.

Maximum Ultrasound-Compressed Conductor Cross-Sectionmm²

Maximum flexible conductor cross-section with ultrasonically compacted strands permitted by the relevant connection point.

Minimum Direct-Pluggable Rigid Conductor Cross-Sectionmm²

Minimum rigid conductor cross-section suitable for direct insertion into a compatible connection without prior actuation of the release mechanism.

Maximum Direct-Pluggable Rigid Conductor Cross-Sectionmm²

Maximum rigid conductor cross-section suitable for direct insertion into a compatible connection without prior actuation of the release mechanism.

Minimum Direct-Pluggable Ferrule Cross-Section without Sleevemm²

Minimum conductor cross-section with a ferrule without an insulating plastic collar suitable for direct insertion into a compatible connection.

Maximum Direct-Pluggable Ferrule Cross-Section without Sleevemm²

Maximum conductor cross-section with a ferrule without an insulating plastic collar suitable for direct insertion into a compatible connection.

Minimum Direct-Pluggable Ferrule Cross-Section with Sleevemm²

Minimum conductor cross-section with a ferrule and insulating plastic collar suitable for direct insertion into a compatible connection.

Maximum Direct-Pluggable Ferrule Cross-Section with Sleevemm²

Maximum conductor cross-section with a ferrule and insulating plastic collar suitable for direct insertion into a compatible connection.

Minimum Cross-Section for Two Equal Rigid Conductorsmm²

Minimum cross-section of each of two equal rigid conductors that may be connected simultaneously to one clamping point.

Maximum Cross-Section for Two Equal Rigid Conductorsmm²

Maximum cross-section of each of two equal rigid conductors that may be connected simultaneously to one clamping point.

Minimum Cross-Section for Two Equal Flexible Conductorsmm²

Minimum cross-section of each of two equal flexible conductors that may be connected simultaneously to one clamping point.

Maximum Cross-Section for Two Equal Flexible Conductorsmm²

Maximum cross-section of each of two equal flexible conductors that may be connected simultaneously to one clamping point.

Minimum Cross-Section for Two Equal Conductors with Ferrules without Sleevesmm²

Minimum cross-section of each of two equal flexible conductors fitted with separate ferrules without insulating collars and permitted for joint connection to one clamping point.

Maximum Cross-Section for Two Equal Conductors with Ferrules without Sleevesmm²

Maximum cross-section of each of two equal flexible conductors fitted with separate ferrules without insulating collars and permitted for joint connection to one clamping point.

Levels Equipotentially Bonded

Indicates whether two or more connection levels are electrically interconnected by the product design and form one potential.

Protection and Safety11
Halogen-Free

Indicates whether the product material is classified as halogen-free according to the characteristics declared by the manufacturer.

IP Rating

Degree of enclosure protection against access to hazardous parts and ingress of solid objects and water, designated by the IP code.

Protection Against Direct Contact

Method or level of protection of the user against direct contact with hazardous live parts.

Finger-Safe

Indicates whether the design prevents finger access to hazardous live parts in the intended condition.

Touch-Safe

Indicates whether the design provides protection against accidental contact with hazardous live parts.

Protective Shrouds Included

Indicates whether insulating or mechanical protective shrouds are included with the product.

Live Parts Covered

Indicates whether live parts are covered by protective elements in the intended product state.

Flammability Class

Classification of a material according to its ability to ignite, sustain combustion, and cease burning under a specified test.

Glow-Wire Test Temperature°C

Temperature of the heated wire used when testing the material or product against an ignition source.

Self-Extinguishing

Indicates whether the material ceases self-sustained burning after the ignition source is removed under specified conditions.

Terminal Cover Supported

Indicates whether the product is compatible with insulating terminal covers or protective terminal shrouds.

Environmental Conditions22
Minimum Operating Temperature°C

Minimum ambient temperature at which normal operation of the product is permitted.

Maximum Operating Temperature°C

Maximum ambient temperature at which normal operation of the product is permitted.

Maximum 24-Hour Average Temperature°C

Maximum permissible average ambient temperature over a consecutive 24-hour period.

Minimum Storage Temperature°C

Minimum ambient temperature permitted during storage of the product while not in operation.

Maximum Storage Temperature°C

Maximum ambient temperature permitted during storage of the product while not in operation.

Minimum Transport Temperature°C

Minimum ambient temperature permitted during transportation of the product.

Maximum Transport Temperature°C

Maximum ambient temperature permitted during transportation of the product.

Minimum Installation Temperature°C

Minimum ambient temperature at which the manufacturer permits installation of the product.

Maximum Installation Temperature°C

Maximum ambient temperature at which the manufacturer permits installation of the product.

Temperature Derating Required

Indicates whether permissible electrical or thermal loading must be reduced as temperature changes.

Temperature Derating Start°C

Temperature above which the permissible product load must be reduced.

Temperature Derating Curve Available

Indicates whether the manufacturer has published the relationship between permissible product load and temperature.

Minimum Relative Humidity%

Minimum relative air humidity permitted for the declared operating or test condition.

Maximum Relative Humidity%

Maximum relative air humidity permitted for the declared operating or test condition.

Relative Humidity Reference Temperature°C

Temperature at which the corresponding relative humidity value is specified or standardized.

Non-Condensing Humidity

Indicates whether the permissible humidity value applies only to non-condensing conditions.

Maximum Installation Altitudem

Maximum altitude above sea level at which the product may be installed without exceeding the declared conditions.

Altitude Derating Required

Indicates whether the permissible product load must be reduced as installation altitude increases.

Altitude Derating Startm

Altitude above sea level above which the permissible product load must be reduced.

Vibration Resistant

Indicates whether the product's resistance to vibration has been verified under the declared conditions.

Mechanical Shock Resistant

Indicates whether the product's resistance to short-duration mechanical shocks has been verified.

Environmental Test Standard

Standard or method used for climatic, mechanical, or combined testing of the product.

Included Equipment10
Terminal Markers Included

Indicates whether terminal markers are included in the product's standard equipment.

Terminal Marker Count

Number of terminal markers included in the product's standard equipment or provided for the specific version.

Terminal Jumpers Included

Indicates whether terminal jumpers are included in the product's standard equipment.

Terminal Jumper Count

Number of terminal jumpers included in the product's standard equipment or provided for the specific version.

Label Holder Included

Indicates whether a label holder is included in the product's standard equipment.

Label Holder Count

Number of label holders included in the product's standard equipment or provided for the specific version.

Documentation Included

Indicates whether documentation is included in the product's standard supply.

Terminal Cover Included

Indicates whether insulating terminal covers or protective terminal shrouds are supplied with the product.

End Cover Included

Indicates whether the required or applicable end cover is supplied with the product.

Partition Plate Included

Indicates whether a compatible partition or insulating plate is supplied with the product.

Special Features19
Internal Bridging Present

Indicates whether multiple connection points are electrically interconnected by an internal current-carrying bridge.

External Bridging Supported

Indicates whether external electrical bridging of connection points or adjacent products is supported.

External Bridging Method

Supported technologies or methods for providing an external electrical bridging connection.

End Cover Required

Indicates whether a separate end cover or closing plate is required to complete installation or the electrical insulation system.

Cross-Connection Channel Count

Number of independent channels or rows provided by the design for installation of electrical cross-connections.

Bridgeable Level Count

Number of electrical levels of the product that may be interconnected using a compatible bridging system.

Bridge Current RatingA

Declared permissible current-carrying capacity of the compatible bridge or cross-connection system when used with the product.

Bridge Reference Conductor Cross-Sectionmm²

Conductor cross-section associated with the declared current rating of the bridge system.

Maximum Rigid Conductor Cross-Section with Insertion Bridgemm²

Maximum rigid conductor cross-section permitted by the connection point when an insertion bridge is installed.

Maximum Flexible Conductor Cross-Section with Insertion Bridgemm²

Maximum flexible conductor cross-section permitted by the connection point when an insertion bridge is installed.

Marking Supported

Indicates whether one or more positions or interfaces are provided for identification marking of the product.

Compatible Marking System

Manufacturer's marking system or family of marking elements compatible with the product.

Marker Carrier Supported

Indicates whether an additional holder or carrier for marking elements can be installed.

Marker Carrier Pitchmm

Pitch of standard marking elements accepted by the compatible marker carrier.

Continuous Strip Marking Supported

Indicates compatibility with a continuous marking strip extending across one or more adjacent terminal blocks.

Partition Plate Supported

Indicates whether a compatible partition or insulating plate can be installed between adjacent terminal blocks or groups of terminal blocks.

Vertical Level Bridging Supported

Indicates whether vertically arranged levels can be electrically connected using a compatible vertical bridge or accessory.

Vertical Level Bridging Present

Indicates whether an electrical connection between vertically arranged levels is integrated into the product.

Per-Level Marking Supported

Indicates whether a separate marking position is provided for each connection level of the multi-level terminal block.

Standards and Compliance35
Conformity Regions

Regions or markets for which the manufacturer declares regulatory or certification compliance of the product.

Certification and Conformity Marks

Certification, market-approval, or conformity marks applicable to the product.

Primary Product Standard

Primary normative document or standard according to which the manufacturer classifies or assesses the product.

Additional Standards

Additional normative documents and standards declared by the manufacturer as applicable to the product.

Declaration of Conformity Available

Indicates whether an official declaration of conformity is available for the product.

Manufacturer Declaration Available

Indicates whether a separate manufacturer declaration concerning declared product characteristics or conformity is available.

Certificate Available

Indicates whether a certificate relating to the declared certification or conformity of the product is available.

Certificate Number

Identification number of the certificate relating to the product or its certified version.

Certification Body

Name of the organization that issued the certificate or performed the relevant conformity assessment.

Third-Party Tested

Indicates whether the product was tested by an organization independent of the manufacturer.

Test Report Available

Indicates whether a test report confirming the declared product characteristics is available.

Type Test Report Available

Indicates whether a type-test report for the product or relevant design is available.

Routine Test Report Available

Indicates whether a report of routine or acceptance tests on the manufactured product is available.

Design Verification Available

Indicates whether documented confirmation of design verification for the product or assembly is available.

Verification Method

Methods used to verify that the design complies with the declared requirements.

CE Marked

Indicates whether the CE marking is applied to the product where applicable.

UKCA Marked

Indicates whether the UKCA marking is applied to the product where applicable.

EAC Marked

Indicates whether the EAC marking is applied to the product where applicable.

UL Listed

Indicates whether the product has a declared UL Listed certification or recognition status.

UL Recognized

Indicates whether the product has a declared UL Recognized certification or recognition status.

cULus Marked

Indicates whether the cULus mark is applied to the product where applicable.

CSA Certified

Indicates whether the product has a declared CSA certification or recognition status.

TÜV Certified

Indicates whether the product has a declared TÜV certification or recognition status.

VDE Certified

Indicates whether the product has a declared VDE certification or recognition status.

RoHS Compliant

Indicates whether product compliance with applicable RoHS restrictions on hazardous substances has been declared.

REACH Compliant

Indicates whether the manufacturer declares compliance of the product with applicable REACH Regulation requirements.

WEEE Applicable

Indicates whether the product falls within the scope of WEEE requirements for waste electrical and electronic equipment.

EN 45545-2 Compliant

Indicates declared compliance of the material or product with the applicable requirements of EN 45545-2 concerning fire behaviour of materials and components used in railway vehicles.

EN 45545-2 Classification

Manufacturer-declared classification according to EN 45545-2, including the applicable requirement set and hazard level where such classification is specified.

IEC 60947-7-1 Compliant

Indicates declared compliance with the applicable IEC 60947-7-1 requirements for terminal blocks for copper conductors and test disconnect terminal blocks where applicable.

UL 1059 Compliant

Indicates declared compliance with the applicable UL 1059 requirements for terminal blocks, including protective-conductor terminal blocks where applicable.

EN 50155 Compliant

Indicates declared compliance or qualification of the product with the applicable EN 50155 requirements for railway rolling-stock equipment.

IEC 61373 Compliant

Indicates declared compliance of the product with the applicable IEC 61373 shock and vibration requirements for railway rolling-stock equipment.

IEC 60079-0 Compliant

Indicates declared compliance of the product with the applicable general IEC 60079-0 requirements for Ex equipment and Ex components intended for explosive atmospheres.

IEC 60079-7 Compliant

Indicates declared compliance of the product with the applicable IEC 60079-7 requirements for equipment or Ex components using type of protection increased safety e.

Logistics10
Net Weightkg

Mass of the product itself, excluding transport packaging, additional accessories, and external equipment.

Gross Weightkg

Mass of the product together with its individual packaging and the accessories included in it.

Package Widthmm

External horizontal dimension of the product's individual package.

Package Heightmm

External vertical dimension of the product's individual package.

Package Depthmm

External depth dimension of the product's individual package.

Packaging Type

Design type of the product's individual or transport packaging.

Units per Package

Number of individual products contained in one packaging unit at the specified level.

Country of Origin

Country of origin of the goods declared for customs or commercial purposes.

HS Code

Commodity code under the international Harmonized Commodity Description and Coding System.

Combined Nomenclature Code

Commodity code under the Combined Nomenclature of the European Union.