Device description

Modular Contactor

Modular electromechanical switching device intended for remote and automatic control of electrical loads.

A modular contactor is intended for repeated remote switching of electrical loads by means of an electromagnetic or electronically controlled actuator.

The device is typically mounted on a DIN rail in a distribution board and is designed for installation alongside other modular equipment.

The main contact system may contain normally open, normally closed, or changeover contacts. Its characteristics include operational currents and voltages, making and breaking capacity, switching frequency, timing characteristics, and power losses.

The control coil is characterized by its voltage and frequency range, operating and drop-out voltage, pull-in and holding power, current, and possible electronic control.

Some versions use wide-range coils, integrated switching-overvoltage suppression, or support an external suppression module.

Auxiliary contacts may be used for signalling, interlocking, and control circuits. Their operational voltages and currents, AC-15 and DC-13 utilization categories, minimum switching values, and operating frequency are specified separately.

The contactor may support additional front and side auxiliary contact blocks, manual operation, mirror contacts, or mechanically linked contacts.

For installation and wiring, the technologies of main, control, and auxiliary terminals, permissible conductor sizes, stripping lengths, and tightening torques are also important.

Selection criteria include load characteristics, utilization category, operational current and voltage, control-circuit parameters, contact arrangement, switching endurance, connection method, and declared compliance with applicable standards.

Components in this subcategory

This subcategory includes modular electromechanical contactors for distribution boards, including versions with different numbers of main and auxiliary contacts, AC or DC coils, and additional modules.

Available parameters

Modular Contactor

189 parameters
General7
Product Series

Commercial or technical designation of a manufacturer's product family sharing a common design and compatible characteristics.

Application

Range of tasks and systems for which the manufacturer recommends the component.

Intended Use

Primary function of the device and its intended use as defined by its design and the manufacturer's documentation.

Installation Location

Permissible installation location of the product: indoors, outdoors, in a technical area, or as part of equipment.

Installation Environment

Environmental conditions under which installation and operation of the product are permitted.

Orientation

Permissible spatial orientation of the component during installation and operation.

Frame Size

Manufacturer-defined designation of the product frame size or construction size.

Dimensions3
Widthmm

External horizontal dimension of the product between its outermost lateral points.

Heightmm

External vertical dimension of the product from its lowest to its highest point.

Depthmm

External distance between the foremost and rearmost surfaces of the product.

Capacity and Layout8
Pole Configuration

Actual electrical pole configuration of the product, including the number and function of switched poles.

Normally Open Auxiliary Contact Count

Number of normally open (NO) auxiliary contacts installed in or supplied with the product.

Normally Closed Auxiliary Contact Count

Number of normally closed (NC) auxiliary contacts installed in or supplied with the product.

Changeover Auxiliary Contact Count

Number of changeover auxiliary contacts installed in or supplied with the product.

Normally Open Main Contact Count

Number of normally open main power contacts or main switching poles.

Normally Closed Main Contact Count

Number of normally closed main power contacts or main switching poles.

Changeover Main Contact Count

Number of main changeover contact systems where the device construction provides main changeover contacts.

Mirror NC Auxiliary Contact Count

Number of normally closed auxiliary contacts declared by the manufacturer as mirror contacts.

Materials and Finish4
Material

Primary material from which the product is manufactured.

Material Grade

Grade, alloy, class, or technical designation of the product's primary material.

Main Contact Material

Electrical contact material used for the main switching contacts.

Auxiliary Contact Material

Electrical contact material used for auxiliary switching contacts.

Mounting and Installation6
DIN Rail Type

Profile type of the DIN rail installed in the product or specified for compatible mounting.

Mounting Type

Installation arrangement permitted by the product design, such as wall-mounted, flush-mounted, floor-mounted, or another specified mounting type.

Mounting Method

Method used to mechanically secure the product to a support, surface, or load-bearing structure.

DIN Rail Mounting Supported

Indicates whether the design provides for mounting equipment on a DIN rail.

Direct Device Mounting Supported

Indicates whether equipment may be mounted directly to the mounting surface without an intermediate DIN rail.

Group Mounting without Spacing Supported

Indicates that adjacent devices may be installed side by side without an additional manufacturer-required spacing element under the stated operating conditions.

Electrical Parameters85
Rated VoltageV

Voltage value assigned to the product by the manufacturer for specified application conditions and characteristics.

Rated Operational VoltageV

Operating-circuit voltage with reference to which the product's performance characteristics are specified.

Maximum Operating VoltageV

Maximum voltage at which continuous operation of the product is permitted under the conditions declared by the manufacturer.

Minimum Operating VoltageV

Minimum voltage at which the manufacturer guarantees the intended operating mode of the product.

Minimum FrequencyHz

Lower limit of the electrical network or signal frequency at which product operation is permitted.

Maximum FrequencyHz

Upper limit of the electrical network or signal frequency at which product operation is permitted.

Control VoltageV

Voltage applied to the control circuit to perform the product's intended functions.

Control Voltage Type

Type of current used in the product's control circuit.

Control FrequencyHz

Frequency of the alternating voltage or signal in the product's control circuit.

Rated CurrentA

Current assigned to the product by the manufacturer for the declared operating and thermal conditions.

Rated Insulation VoltageV

Voltage with reference to which the product's insulation clearances and dielectric properties are specified.

Rated Impulse Withstand VoltagekV

Peak value of an impulse voltage of specified waveform that the product insulation must withstand without breakdown.

Utilization Category

Manufacturer-declared utilization category defining the load characteristics and switching conditions according to the applicable standard.

Conventional Free-Air Thermal CurrentA

Conventional free-air thermal current Ith that the device can carry under specified steady-state conditions in free air.

Conventional Enclosed Thermal CurrentA

Conventional enclosed thermal current Ithe that the device can carry under specified steady-state conditions inside the intended enclosure.

Mechanical Endurancecycles

Declared number of mechanical operating cycles that the product can perform without electrical switching load.

Electrical Endurancecycles

Declared number of electrical load-switching cycles under the conditions specified by the manufacturer.

Opening Timems

Manufacturer-declared opening time of the switching device or its contact mechanism under specified conditions.

Closing Timems

Manufacturer-declared closing time of the switching device or its contact mechanism under specified conditions.

Minimum Control VoltageV

Minimum control-circuit supply voltage supported by the product or electronic coil.

Maximum Control VoltageV

Maximum control-circuit supply voltage supported by the product or electronic coil.

Minimum Control FrequencyHz

Minimum AC control-circuit frequency supported by the electromagnetic or electronic coil.

Maximum Control FrequencyHz

Maximum AC control-circuit frequency supported by the electromagnetic or electronic coil.

Minimum Coil Operating Voltage Ratio%

Minimum manufacturer-declared coil operating voltage expressed as a percentage of rated control voltage Uc.

Maximum Coil Operating Voltage Ratio%

Maximum manufacturer-declared coil operating voltage expressed as a percentage of rated control voltage Uc.

Minimum Coil Drop-Out Voltage Ratio%

Minimum declared drop-out voltage of the contactor coil expressed as a percentage of rated control voltage Uc, where a range is specified.

Maximum Coil Drop-Out Voltage Ratio%

Maximum declared drop-out voltage of the contactor coil expressed as a percentage of rated control voltage Uc.

Coil Pull-In Apparent PowerVA

Apparent power consumed by an AC-operated control coil during pull-in or inrush.

Coil Holding Apparent PowerVA

Apparent power consumed by an AC-operated control coil in the sealed or holding state.

Coil Pull-In PowerW

Active or DC power consumed by the contactor control circuit during pull-in or inrush.

Coil Holding PowerW

Active or DC power consumed by the contactor control circuit in the sealed or holding state.

Coil Inrush CurrentA

Manufacturer-declared current drawn by the control coil during initial energization.

Coil Holding CurrentA

Manufacturer-declared current drawn by the control coil in the sealed or holding state.

Electronic Coil Control

Indicates that the electromagnetic actuator is controlled by integrated electronics rather than a conventional direct coil connection only.

Wide-Range Control Coil

Indicates that one coil or electronic control module supports a manufacturer-declared wide control-voltage range.

Integrated Coil Suppression

Indicates that suppression of the switching overvoltage generated by the control coil is integrated into the product.

Coil Suppression Type

Electrical suppression technology integrated in or explicitly supplied with the contactor control coil.

Control Terminal Connection Type

Conductor connection technology used specifically for the control-circuit terminals.

Minimum Control Terminal Conductor Cross-Sectionmm²

Minimum conductor cross-section accepted by the control-circuit terminal.

Maximum Control Terminal Conductor Cross-Sectionmm²

Maximum conductor cross-section accepted by the control-circuit terminal.

Control Terminal Tightening TorqueNm

Manufacturer-declared tightening torque specifically for a screw-type control-circuit terminal.

Rated Operational Current AC-1A

Rated operational current Ie for utilization category AC-1 at the associated manufacturer-declared reference voltage.

AC-1 Rated Operational Current Reference VoltageV

Operational voltage associated with the stored AC-1 rated operational current.

Maximum Making CapacityA

Maximum manufacturer-declared current that the contact system can make under the stated operating conditions.

Maximum Breaking CapacityA

Maximum manufacturer-declared current that the contact system can break under the stated operating conditions.

Maximum Mechanical Switching Frequencycycles/h

Maximum manufacturer-declared mechanical operating frequency without regard to the electrical load.

Maximum Electrical Switching Frequencycycles/h

Maximum manufacturer-declared switching frequency under the associated utilization category and load conditions.

Electrical Switching Frequency Utilization Category

Utilization category associated with the stored maximum electrical switching frequency.

Minimum Coil Energization to NO Contact Closing Timems

Minimum manufacturer-declared time from coil energization to closing of a normally open contact.

Maximum Coil Energization to NO Contact Closing Timems

Maximum manufacturer-declared time from coil energization to closing of a normally open contact.

Minimum Coil Energization to NC Contact Opening Timems

Minimum manufacturer-declared time from coil energization to opening of a normally closed contact.

Maximum Coil Energization to NC Contact Opening Timems

Maximum manufacturer-declared time from coil energization to opening of a normally closed contact.

Minimum Coil De-Energization to NO Contact Opening Timems

Minimum manufacturer-declared time from coil de-energization to opening of a normally open contact.

Maximum Coil De-Energization to NO Contact Opening Timems

Maximum manufacturer-declared time from coil de-energization to opening of a normally open contact.

Minimum Coil De-Energization to NC Contact Closing Timems

Minimum manufacturer-declared time from coil de-energization to closing of a normally closed contact.

Maximum Coil De-Energization to NC Contact Closing Timems

Maximum manufacturer-declared time from coil de-energization to closing of a normally closed contact.

Power Dissipation per Pole AC-1W

Manufacturer-declared power dissipation per main pole at the stated AC-1 operating condition.

Maximum Auxiliary Contact Rated Operational VoltageV

Maximum manufacturer-declared operational voltage Ue of the auxiliary contact circuit.

Auxiliary Contact Rated Insulation VoltageV

Rated insulation voltage Ui specifically declared for the auxiliary contact circuit.

Auxiliary Contact Rated Impulse Withstand VoltagekV

Rated impulse withstand voltage Uimp specifically declared for the auxiliary contact circuit.

Minimum Auxiliary Contact Circuit FrequencyHz

Minimum AC frequency applicable to the declared auxiliary-contact electrical ratings.

Maximum Auxiliary Contact Circuit FrequencyHz

Maximum AC frequency applicable to the declared auxiliary-contact electrical ratings.

Auxiliary Contact Conventional Free-Air Thermal CurrentA

Conventional free-air thermal current Ith specifically declared for the auxiliary contacts.

Auxiliary Contact Rated Operational Current AC-15A

Rated operational current Ie of the auxiliary contacts for utilization category AC-15 at the associated reference voltage.

Auxiliary Contact AC-15 Reference VoltageV

Operational voltage associated with the stored AC-15 auxiliary-contact rated current.

Auxiliary Contact Rated Operational Current DC-13A

Rated operational current Ie of the auxiliary contacts for utilization category DC-13 at the associated reference voltage.

Auxiliary Contact DC-13 Reference VoltageV

Operational voltage associated with the stored DC-13 auxiliary-contact rated current.

Auxiliary Contact Minimum Switching VoltageV

Minimum switching voltage for which the manufacturer declares reliable auxiliary-contact operation.

Auxiliary Contact Minimum Switching CurrentA

Minimum switching current for which the manufacturer declares reliable auxiliary-contact operation.

Auxiliary Contact Non-Overlap Timems

Manufacturer-declared non-overlapping time between opening and closing of associated NO and NC auxiliary contacts.

Maximum Auxiliary Contact Switching Frequency AC-15cycles/h

Maximum manufacturer-declared electrical switching frequency of the auxiliary contacts under AC-15 conditions.

Maximum Auxiliary Contact Switching Frequency DC-13cycles/h

Maximum manufacturer-declared electrical switching frequency of the auxiliary contacts under DC-13 conditions.

Auxiliary Contact Short-Time Withstand Current 1 sA

Manufacturer-declared short-time withstand current of the auxiliary circuit for a duration of 1 second.

Auxiliary Contact Short-Time Withstand Current 0.1 sA

Manufacturer-declared short-time withstand current of the auxiliary circuit for a duration of 0.1 second.

Auxiliary Contact Power Dissipation per PoleW

Manufacturer-declared power dissipation per auxiliary-contact pole at the stated reference current.

Main Terminal Connection Type

Conductor connection technology used specifically for the main power terminals of the switching device.

Minimum Main Terminal Conductor Cross-Sectionmm²

Minimum conductor cross-section accepted by the main power terminal.

Maximum Main Terminal Conductor Cross-Sectionmm²

Maximum conductor cross-section accepted by the main power terminal.

Main Terminal Tightening TorqueNm

Manufacturer-declared tightening torque specifically for screw, bolt or clamp-type main power terminals.

Minimum Main Terminal Stripping Lengthmm

Minimum conductor stripping length specified for the main power terminal.

Maximum Main Terminal Stripping Lengthmm

Maximum conductor stripping length specified for the main power terminal.

Auxiliary Terminal Connection Type

Conductor connection technology used specifically for auxiliary-contact terminals.

Minimum Auxiliary Terminal Conductor Cross-Sectionmm²

Minimum conductor cross-section accepted by an auxiliary-contact terminal.

Maximum Auxiliary Terminal Conductor Cross-Sectionmm²

Maximum conductor cross-section accepted by an auxiliary-contact terminal.

Auxiliary Terminal Tightening TorqueNm

Manufacturer-declared tightening torque specifically for screw-type auxiliary-contact terminals.

Protection and Safety11
Halogen-Free

Indicates whether the product material is classified as halogen-free according to the characteristics declared by the manufacturer.

External Short-Circuit Protection Required

Indicates whether an external short-circuit protective device is required for the declared operation of the product.

IP Rating

Degree of enclosure protection against access to hazardous parts and ingress of solid objects and water, designated by the IP code.

IK Rating

Class of enclosure resistance to external mechanical impacts designated by the IK code.

Protection Against Direct Contact

Method or level of protection of the user against direct contact with hazardous live parts.

Finger-Safe

Indicates whether the design prevents finger access to hazardous live parts in the intended condition.

Touch-Safe

Indicates whether the design provides protection against accidental contact with hazardous live parts.

Flammability Class

Classification of a material according to its ability to ignite, sustain combustion, and cease burning under a specified test.

Glow-Wire Test Temperature°C

Temperature of the heated wire used when testing the material or product against an ignition source.

Maximum Backup Protection CurrentA

Maximum rated current of an external backup overcurrent protective device permitted by the manufacturer for use with the SPD.

Backup Protection Device Type

Type of upstream overcurrent protective device permitted or required by the manufacturer for the declared conditional short-circuit withstand rating or SCCR.

Environmental Conditions17
Minimum Operating Temperature°C

Minimum ambient temperature at which normal operation of the product is permitted.

Maximum Operating Temperature°C

Maximum ambient temperature at which normal operation of the product is permitted.

Maximum 24-Hour Average Temperature°C

Maximum permissible average ambient temperature over a consecutive 24-hour period.

Minimum Storage Temperature°C

Minimum ambient temperature permitted during storage of the product while not in operation.

Maximum Storage Temperature°C

Maximum ambient temperature permitted during storage of the product while not in operation.

Minimum Transport Temperature°C

Minimum ambient temperature permitted during transportation of the product.

Maximum Transport Temperature°C

Maximum ambient temperature permitted during transportation of the product.

Temperature Derating Required

Indicates whether permissible electrical or thermal loading must be reduced as temperature changes.

Temperature Derating Start°C

Temperature above which the permissible product load must be reduced.

Temperature Derating Curve Available

Indicates whether the manufacturer has published the relationship between permissible product load and temperature.

Minimum Relative Humidity%

Minimum relative air humidity permitted for the declared operating or test condition.

Maximum Relative Humidity%

Maximum relative air humidity permitted for the declared operating or test condition.

Maximum Installation Altitudem

Maximum altitude above sea level at which the product may be installed without exceeding the declared conditions.

Altitude Derating Required

Indicates whether the permissible product load must be reduced as installation altitude increases.

Altitude Derating Startm

Altitude above sea level above which the permissible product load must be reduced.

Vibration Resistant

Indicates whether the product's resistance to vibration has been verified under the declared conditions.

Mechanical Shock Resistant

Indicates whether the product's resistance to short-duration mechanical shocks has been verified.

Included Equipment2
Documentation Included

Indicates whether documentation is included in the product's standard supply.

Auxiliary Contacts Included

Indicates whether one or more auxiliary contacts are included in the standard product configuration.

Special Features11
Auxiliary Contacts Supported

Indicates whether the product supports installation or connection of specified auxiliary contacts.

Mechanically Linked Auxiliary Contacts

Indicates that the applicable auxiliary contact elements are manufacturer-declared mechanically linked contacts.

Mirror Contacts Present

Indicates that one or more normally closed auxiliary contacts are manufacturer-declared mirror contacts relative to the main normally open contacts.

Auxiliary Contact Switching Sequence

Switching sequence between associated NO and NC auxiliary contacts.

Hum-Free Operation

Indicates that the contactor is designed for hum-free or substantially hum-free electromagnetic operation, particularly for noise-sensitive installations.

Manual Override Present

Indicates that the contactor provides a local manual override mechanism in addition to electrical coil operation.

Manual Override Positions

Positions or modes available on the local manual override mechanism.

Front Auxiliary Contact Block Supported

Indicates compatibility with an auxiliary contact block mounted on the front of the contactor.

Side Auxiliary Contact Block Supported

Indicates compatibility with an auxiliary contact block mounted on the side of the contactor.

Surge Suppression Module Supported

Indicates compatibility with an external or add-on suppression module for limiting switching overvoltage generated by the control coil.

Replaceable Coil

Indicates that the electromagnetic control coil can be replaced independently of the complete contactor.

Standards and Compliance25
Conformity Regions

Regions or markets for which the manufacturer declares regulatory or certification compliance of the product.

Certification and Conformity Marks

Certification, market-approval, or conformity marks applicable to the product.

Primary Product Standard

Primary normative document or standard according to which the manufacturer classifies or assesses the product.

Additional Standards

Additional normative documents and standards declared by the manufacturer as applicable to the product.

Declaration of Conformity Available

Indicates whether an official declaration of conformity is available for the product.

Certificate Available

Indicates whether a certificate relating to the declared certification or conformity of the product is available.

Certificate Number

Identification number of the certificate relating to the product or its certified version.

Certification Body

Name of the organization that issued the certificate or performed the relevant conformity assessment.

Third-Party Tested

Indicates whether the product was tested by an organization independent of the manufacturer.

CE Marked

Indicates whether the CE marking is applied to the product where applicable.

UKCA Marked

Indicates whether the UKCA marking is applied to the product where applicable.

EAC Marked

Indicates whether the EAC marking is applied to the product where applicable.

UL Listed

Indicates whether the product has a declared UL Listed certification or recognition status.

UL Recognized

Indicates whether the product has a declared UL Recognized certification or recognition status.

cULus Marked

Indicates whether the cULus mark is applied to the product where applicable.

CSA Certified

Indicates whether the product has a declared CSA certification or recognition status.

TÜV Certified

Indicates whether the product has a declared TÜV certification or recognition status.

VDE Certified

Indicates whether the product has a declared VDE certification or recognition status.

RoHS Compliant

Indicates whether product compliance with applicable RoHS restrictions on hazardous substances has been declared.

REACH Compliant

Indicates whether the manufacturer declares compliance of the product with applicable REACH Regulation requirements.

WEEE Applicable

Indicates whether the product falls within the scope of WEEE requirements for waste electrical and electronic equipment.

IEC 60947-4-1 Compliant

Compliance with IEC 60947-4-1 requirements applicable to electromechanical contactors and motor-starters.

IEC 61095 Compliant

Compliance with IEC 61095 requirements for electromechanical contactors intended for household and similar purposes.

UL 60947-4-1 Compliant

Compliance with UL 60947-4-1 requirements applicable to contactors and motor-starters.

IEC 60947-5-1 Compliant

Compliance with applicable IEC 60947-5-1 requirements for control-circuit devices and switching elements.

Logistics10
Net Weightkg

Mass of the product itself, excluding transport packaging, additional accessories, and external equipment.

Gross Weightkg

Mass of the product together with its individual packaging and the accessories included in it.

Package Widthmm

External horizontal dimension of the product's individual package.

Package Heightmm

External vertical dimension of the product's individual package.

Package Depthmm

External depth dimension of the product's individual package.

Packaging Type

Design type of the product's individual or transport packaging.

Units per Package

Number of individual products contained in one packaging unit at the specified level.

Country of Origin

Country of origin of the goods declared for customs or commercial purposes.

HS Code

Commodity code under the international Harmonized Commodity Description and Coding System.

Combined Nomenclature Code

Commodity code under the Combined Nomenclature of the European Union.