Device description

Latching Relay

Electromechanical relay that retains the selected switching state after the control action is removed.

A latching relay is intended to switch between stable states while retaining the selected position without continuously energizing the control coil.

Switching may be performed by one bistable coil or by separate SET and RESET windings.

Separate coils may have individual rated voltages, currents, resistances, and power values. Reliable switching requires consideration of minimum SET and RESET pulse duration, maximum operate voltage, and transition times between states.

If the SET and RESET windings are electrically isolated, dielectric test voltage between them may be specified.

The contact system may contain normally open, normally closed, and changeover contacts and retain the corresponding position after the control signal disappears.

Such relays are used in state-memory circuits, lighting control, automation, energy-efficient systems, and other applications requiring state retention without continuous coil power.

Selection criteria include coil configuration, control-pulse parameters, number of stable states, contact configuration, load characteristics, and electrical endurance.

Components in this subcategory

This subcategory includes latching electromechanical relays with one or more control windings and a retained switching state.

Available parameters

Latching Relay

166 parameters
General6
Product Series

Commercial or technical designation of a manufacturer's product family sharing a common design and compatible characteristics.

Application

Range of tasks and systems for which the manufacturer recommends the component.

Intended Use

Primary function of the device and its intended use as defined by its design and the manufacturer's documentation.

Installation Location

Permissible installation location of the product: indoors, outdoors, in a technical area, or as part of equipment.

Installation Environment

Environmental conditions under which installation and operation of the product are permitted.

Orientation

Permissible spatial orientation of the component during installation and operation.

Dimensions3
Widthmm

External horizontal dimension of the product between its outermost lateral points.

Heightmm

External vertical dimension of the product from its lowest to its highest point.

Depthmm

External distance between the foremost and rearmost surfaces of the product.

Capacity and Layout8
Relay Output Count

Number of independent relay outputs or sets of switching contacts provided by the product.

Relay Output Contact Configuration

Contact configurations provided for the product relay outputs.

Normally Open Relay Contact Count

Number of normally open switching contact sets provided by the relay.

Normally Closed Relay Contact Count

Number of normally closed switching contact sets provided by the relay.

Changeover Relay Contact Count

Number of changeover contact sets provided by the relay.

Stable State Count

Number of stable switching states that can be maintained by the device without a continuous control command.

Latching Coil Configuration

Winding configuration used for electrically setting and resetting a latching relay.

Maximum Illuminated Push Button Count

Maximum number of illuminated control push buttons permitted on the relay control circuit under the manufacturer-declared leakage-current conditions.

Materials and Finish3
Material

Primary material from which the product is manufactured.

Material Grade

Grade, alloy, class, or technical designation of the product's primary material.

Relay Contact Material

Electrical contact material or contact-material system used by the relay switching contacts.

Mounting and Installation5
DIN Rail Type

Profile type of the DIN rail installed in the product or specified for compatible mounting.

Mounting Type

Installation arrangement permitted by the product design, such as wall-mounted, flush-mounted, floor-mounted, or another specified mounting type.

Mounting Method

Method used to mechanically secure the product to a support, surface, or load-bearing structure.

DIN Rail Mounting Supported

Indicates whether the design provides for mounting equipment on a DIN rail.

Direct Device Mounting Supported

Indicates whether equipment may be mounted directly to the mounting surface without an intermediate DIN rail.

Electrical Parameters66
Control VoltageV

Voltage applied to the control circuit to perform the product's intended functions.

Control Voltage Type

Type of current used in the product's control circuit.

Control FrequencyHz

Frequency of the alternating voltage or signal in the product's control circuit.

Rated Insulation VoltageV

Voltage with reference to which the product's insulation clearances and dielectric properties are specified.

Rated Impulse Withstand VoltagekV

Peak value of an impulse voltage of specified waveform that the product insulation must withstand without breakdown.

Dielectric Test VoltageV

Test voltage applied to verify the dielectric strength of the product insulation.

Minimum Insulation ResistanceMΩ

Minimum permissible insulation resistance between the specified electrically separated parts.

Overvoltage Category

Category characterizing the expected level of impulse overvoltages at the product's point of use.

Pollution Degree

Degree of pollution of the surrounding microenvironment considered when selecting insulation distances and product characteristics.

Insulation Type

Type of electrical insulation used, considered in terms of its protective function and construction.

Electrical Protection Class

Class of protection against electric shock determined by the product design and protective connection method.

Mechanical Endurancecycles

Declared number of mechanical operating cycles that the product can perform without electrical switching load.

Electrical Endurancecycles

Declared number of electrical load-switching cycles under the conditions specified by the manufacturer.

Relay Contact Maximum Switching VoltageV

Maximum manufacturer-declared voltage that may be switched by the relay-output contacts.

Relay Contact Maximum Switching CurrentA

Maximum manufacturer-declared current that may be switched by the relay-output contacts.

Relay Contact Maximum Switching PowerW

Maximum manufacturer-declared active power that may be switched by the relay-output contacts.

Minimum Control VoltageV

Minimum control-circuit supply voltage supported by the product or electronic coil.

Maximum Control VoltageV

Maximum control-circuit supply voltage supported by the product or electronic coil.

Minimum Control FrequencyHz

Minimum AC control-circuit frequency supported by the electromagnetic or electronic coil.

Maximum Control FrequencyHz

Maximum AC control-circuit frequency supported by the electromagnetic or electronic coil.

Relay Drive Function

Operating principle of the relay drive with respect to retention or reset of the switching state.

Relay Drive Polarity

Indicates whether correct polarity of the DC coil or electronic relay input must be observed.

Coil ResistanceΩ

Manufacturer-declared DC resistance of the relay coil at the stated reference temperature.

Coil Resistance Tolerance%

Manufacturer-declared tolerance of the relay coil resistance.

Nominal Coil PowerW

Nominal power consumption of the relay coil or electromagnetic drive at rated control voltage.

Nominal Coil CurrentA

Nominal current consumed by the relay coil at its rated control voltage.

Maximum Coil Pick-Up Voltage Ratio%

Maximum pick-up or must-operate voltage expressed as a percentage of the rated coil or control voltage.

Relay Operate Timems

Manufacturer-declared time from application of the control signal until the relay reaches its operated switching state.

Relay Release Timems

Manufacturer-declared time from removal of the control signal until the relay returns to its released switching state.

Contact Bounce Timems

Manufacturer-declared duration of mechanical contact bounce following relay contact operation.

Relay Contact Minimum Switching VoltageV

Minimum manufacturer-declared switching voltage for reliable operation of the relay contact.

Relay Contact Minimum Switching CurrentA

Minimum manufacturer-declared switching current for reliable relay-contact operation.

Relay Contact Limiting Continuous CurrentA

Maximum continuous current permitted through a closed relay contact under the manufacturer-declared conditions.

Relay Contact Maximum Inrush CurrentA

Maximum short-duration inrush current permitted through the relay switching contact.

Relay Contact Maximum AC Switching VoltageV

Maximum AC switching voltage of the relay output contact.

Relay Contact Maximum DC Switching VoltageV

Maximum DC switching voltage of the relay output contact.

Relay Contact Maximum Switching Apparent PowerVA

Maximum manufacturer-declared AC switching capacity of the relay contacts expressed as apparent power.

Relay Contact ResistancemΩ

Manufacturer-declared electrical resistance of a closed relay switching contact under the specified measurement condition.

Coil-to-Contact Dielectric Test VoltageV

Dielectric test voltage applied between the relay coil or control-input circuit and the switching-contact circuit.

Contact-to-Contact Dielectric Test VoltageV

Dielectric test voltage applied between electrically isolated relay contact circuits or contact sets.

Set Coil Rated VoltageV

Rated voltage of the coil or winding used to place a latching relay into the SET state.

Reset Coil Rated VoltageV

Rated voltage of the coil or winding used to return a latching relay to the RESET state.

Set Coil Rated CurrentA

Rated current of the SET coil at the manufacturer-declared rated voltage.

Reset Coil Rated CurrentA

Rated current of the RESET coil at the manufacturer-declared rated voltage.

Set Coil ResistanceΩ

Manufacturer-declared electrical resistance of the SET coil at the stated reference temperature.

Reset Coil ResistanceΩ

Manufacturer-declared electrical resistance of the RESET coil at the stated reference temperature.

Set Coil Nominal PowerW

Nominal active or DC power consumption of the SET coil where separately specified by the manufacturer.

Reset Coil Nominal PowerW

Nominal active or DC power consumption of the RESET coil where separately specified by the manufacturer.

Maximum Set Coil Operating Voltage Ratio%

Maximum SET voltage required for operation, expressed as a percentage of the rated SET-coil voltage.

Maximum Reset Coil Operating Voltage Ratio%

Maximum RESET voltage required for operation, expressed as a percentage of the rated RESET-coil voltage.

Relay Set Timems

Manufacturer-declared time from application of a valid SET command until the relay reaches the SET switching state.

Relay Reset Timems

Manufacturer-declared time from application of a valid RESET command until the relay reaches the RESET switching state.

Minimum Set Pulse Durationms

Minimum duration of the SET control pulse required for reliable latching operation.

Minimum Reset Pulse Durationms

Minimum duration of the RESET control pulse required for reliable reset operation.

Minimum Control Pulse Durationms

Minimum duration of a general toggle or step control pulse accepted by an impulse or bistable relay.

Maximum Control Pulse Durationms

Maximum duration of a control signal or pulse permitted by the relay manufacturer.

Continuous Control Signal Permitted

Indicates that a continuous or prolonged control signal may be applied without violating the manufacturer-declared operating conditions.

Illuminated Push Button Supported

Indicates that the control input is suitable for operation with illuminated push buttons having a manufacturer-limited leakage current.

Maximum Illuminated Push Button Leakage CurrentA

Maximum permitted leakage current per illuminated push button or equivalent control device. UI may display the value in mA.

Set-to-Reset Coil Dielectric Test VoltageV

Manufacturer-declared dielectric test voltage between electrically separate SET and RESET windings of a latching relay.

Relay Contact Load Categories

IEC 61810 contact-load categories for which the relay contact characteristics or endurance are declared.

Supported Relay Load Types

Electrical load types for which switching capability or endurance is explicitly declared by the manufacturer.

Coil Inductance — EnergizedH

Manufacturer-declared relay coil inductance with the armature in the operated or energized position.

Coil Inductance — De-EnergizedH

Manufacturer-declared relay coil inductance with the armature in the released or de-energized position.

Maximum Permissible Coil Voltage Ratio%

Maximum continuous or manufacturer-permitted coil voltage expressed as a percentage of rated coil voltage under the specified conditions.

Relay Terminal Style

Physical terminal or lead execution provided directly on the relay body, distinct from the connection technology of a separate relay socket.

Protection and Safety8
Halogen-Free

Indicates whether the product material is classified as halogen-free according to the characteristics declared by the manufacturer.

IP Rating

Degree of enclosure protection against access to hazardous parts and ingress of solid objects and water, designated by the IP code.

IK Rating

Class of enclosure resistance to external mechanical impacts designated by the IK code.

Protection Against Direct Contact

Method or level of protection of the user against direct contact with hazardous live parts.

Finger-Safe

Indicates whether the design prevents finger access to hazardous live parts in the intended condition.

Touch-Safe

Indicates whether the design provides protection against accidental contact with hazardous live parts.

Flammability Class

Classification of a material according to its ability to ignite, sustain combustion, and cease burning under a specified test.

Glow-Wire Test Temperature°C

Temperature of the heated wire used when testing the material or product against an ignition source.

Environmental Conditions18
Minimum Operating Temperature°C

Minimum ambient temperature at which normal operation of the product is permitted.

Maximum Operating Temperature°C

Maximum ambient temperature at which normal operation of the product is permitted.

Maximum 24-Hour Average Temperature°C

Maximum permissible average ambient temperature over a consecutive 24-hour period.

Minimum Storage Temperature°C

Minimum ambient temperature permitted during storage of the product while not in operation.

Maximum Storage Temperature°C

Maximum ambient temperature permitted during storage of the product while not in operation.

Minimum Transport Temperature°C

Minimum ambient temperature permitted during transportation of the product.

Maximum Transport Temperature°C

Maximum ambient temperature permitted during transportation of the product.

Temperature Derating Required

Indicates whether permissible electrical or thermal loading must be reduced as temperature changes.

Temperature Derating Start°C

Temperature above which the permissible product load must be reduced.

Temperature Derating Curve Available

Indicates whether the manufacturer has published the relationship between permissible product load and temperature.

Minimum Relative Humidity%

Minimum relative air humidity permitted for the declared operating or test condition.

Maximum Relative Humidity%

Maximum relative air humidity permitted for the declared operating or test condition.

Non-Condensing Humidity

Indicates whether the permissible humidity value applies only to non-condensing conditions.

Maximum Installation Altitudem

Maximum altitude above sea level at which the product may be installed without exceeding the declared conditions.

Altitude Derating Required

Indicates whether the permissible product load must be reduced as installation altitude increases.

Altitude Derating Startm

Altitude above sea level above which the permissible product load must be reduced.

Vibration Resistant

Indicates whether the product's resistance to vibration has been verified under the declared conditions.

Mechanical Shock Resistant

Indicates whether the product's resistance to short-duration mechanical shocks has been verified.

Included Equipment1
Documentation Included

Indicates whether documentation is included in the product's standard supply.

Special Features13
Status Indicator Present

Indicates whether the product has a local visual or mechanical indicator of operating, fault, or end-of-life status.

Status Indicator Types

Types of local visual or mechanical status indication provided by the product design.

Integrated Coil Suppression

Indicates that suppression of the switching overvoltage generated by the control coil is integrated into the product.

Coil Suppression Type

Electrical suppression technology integrated in or explicitly supplied with the contactor control coil.

Manual Override Present

Indicates that the contactor provides a local manual override mechanism in addition to electrical coil operation.

Relay Contact Structure

Mechanical structure of an individual switching contact system, for example single, double or bifurcated contact.

Operating Voltage Indicator Present

Indicates that a local indicator shows the presence of relay control or input voltage.

State Retained without Control Power

Indicates that the relay maintains its last switching state after removal or loss of control power.

Relay State Change Command

Control command types supported for changing or explicitly setting the retained switching state.

Central Control Supported

Indicates that the product supports a central control command or function affecting one or more controlled channels, outputs or loads.

Central ON Input Supported

Indicates support for an explicit central command that forces or sets the relay to the ON state.

Central OFF Input Supported

Indicates support for an explicit central command that forces or resets the relay to the OFF state.

Relay Contact Break Configuration

Number or arrangement of electrical contact gaps opened within one switched current path, such as single-break or double-break construction.

Standards and Compliance25
Conformity Regions

Regions or markets for which the manufacturer declares regulatory or certification compliance of the product.

Certification and Conformity Marks

Certification, market-approval, or conformity marks applicable to the product.

Primary Product Standard

Primary normative document or standard according to which the manufacturer classifies or assesses the product.

Additional Standards

Additional normative documents and standards declared by the manufacturer as applicable to the product.

Declaration of Conformity Available

Indicates whether an official declaration of conformity is available for the product.

Certificate Available

Indicates whether a certificate relating to the declared certification or conformity of the product is available.

Certificate Number

Identification number of the certificate relating to the product or its certified version.

Certification Body

Name of the organization that issued the certificate or performed the relevant conformity assessment.

Third-Party Tested

Indicates whether the product was tested by an organization independent of the manufacturer.

CE Marked

Indicates whether the CE marking is applied to the product where applicable.

UKCA Marked

Indicates whether the UKCA marking is applied to the product where applicable.

EAC Marked

Indicates whether the EAC marking is applied to the product where applicable.

UL Listed

Indicates whether the product has a declared UL Listed certification or recognition status.

UL Recognized

Indicates whether the product has a declared UL Recognized certification or recognition status.

cULus Marked

Indicates whether the cULus mark is applied to the product where applicable.

CSA Certified

Indicates whether the product has a declared CSA certification or recognition status.

TÜV Certified

Indicates whether the product has a declared TÜV certification or recognition status.

VDE Certified

Indicates whether the product has a declared VDE certification or recognition status.

RoHS Compliant

Indicates whether product compliance with applicable RoHS restrictions on hazardous substances has been declared.

REACH Compliant

Indicates whether the manufacturer declares compliance of the product with applicable REACH Regulation requirements.

WEEE Applicable

Indicates whether the product falls within the scope of WEEE requirements for waste electrical and electronic equipment.

IEC 61810-1 Compliant

Compliance with applicable IEC 61810-1 general and safety requirements for electromechanical elementary relays.

IEC 61810-2 Compliant

Compliance with IEC 61810-2 requirements applicable to reliability evaluation of electromechanical elementary relays.

IEC 61810-7 Compliant

Compliance with applicable IEC 61810-7 test and measurement procedures for electromechanical elementary relays.

UL 61810-1 Compliant

Compliance with UL 61810-1 requirements for electromechanical elementary relays.

Logistics10
Net Weightkg

Mass of the product itself, excluding transport packaging, additional accessories, and external equipment.

Gross Weightkg

Mass of the product together with its individual packaging and the accessories included in it.

Package Widthmm

External horizontal dimension of the product's individual package.

Package Heightmm

External vertical dimension of the product's individual package.

Package Depthmm

External depth dimension of the product's individual package.

Packaging Type

Design type of the product's individual or transport packaging.

Units per Package

Number of individual products contained in one packaging unit at the specified level.

Country of Origin

Country of origin of the goods declared for customs or commercial purposes.

HS Code

Commodity code under the international Harmonized Commodity Description and Coding System.

Combined Nomenclature Code

Commodity code under the Combined Nomenclature of the European Union.