Device description

Multifunction Monitoring Relay

Universal monitoring relay capable of measuring and supervising several electrical or process quantities and performing multiple independent monitoring functions.

A multifunction monitoring relay combines several measurement, monitoring, signalling, and control functions in one device.

Depending on the model, it may supervise voltage, current, frequency, phase conditions, power, power factor, temperature, liquid level, and other parameters. Several functions may operate simultaneously with independent thresholds, delays, and outputs.

Programmable devices may support several parameter sets, assignment of functions to digital inputs and relay outputs, local configuration, measured-value and event memory, time stamps, and trend data.

Models with digital communication may provide remote measured-value readout, diagnostics, and testing. Selection criteria include the number of simultaneously active functions, configurability of inputs and outputs, parameter memory, diagnostic functions, and supported communication interfaces.

Components in this subcategory

Universal and programmable monitoring relays, devices combining several monitored quantities, and intelligent relays with configurable inputs, outputs, display, memory, and digital communication.

Available parameters

Multifunction Monitoring Relay

648 parameters
General7
Product Series

Commercial or technical designation of a manufacturer's product family sharing a common design and compatible characteristics.

Application

Range of tasks and systems for which the manufacturer recommends the component.

Intended Use

Primary function of the device and its intended use as defined by its design and the manufacturer's documentation.

Installation Location

Permissible installation location of the product: indoors, outdoors, in a technical area, or as part of equipment.

Installation Environment

Environmental conditions under which installation and operation of the product are permitted.

Orientation

Permissible spatial orientation of the component during installation and operation.

Monitoring Domains Supported

High-level electrical or process monitoring domains supported by the product.

Dimensions3
Widthmm

External horizontal dimension of the product between its outermost lateral points.

Heightmm

External vertical dimension of the product from its lowest to its highest point.

Depthmm

External distance between the foremost and rearmost surfaces of the product.

Capacity and Layout23
Digital Input Count

Number of available digital inputs of the product.

Digital Output Count

Number of available digital outputs of the product.

Relay Output Count

Number of independent relay outputs or sets of switching contacts provided by the product.

Relay Output Contact Configuration

Contact configurations provided for the product relay outputs.

Relay Output Functions

Functions permanently assigned or assignable to the product relay outputs.

Normally Open Relay Contact Count

Number of normally open switching contact sets provided by the relay.

Normally Closed Relay Contact Count

Number of normally closed switching contact sets provided by the relay.

Changeover Relay Contact Count

Number of changeover contact sets provided by the relay.

Monitored Level Point Count

Number of distinct liquid level points that can be evaluated by one monitoring function or device.

Level Monitoring Channel Count

Number of independent level monitoring channels provided by the device.

Maximum Level Probe Count

Maximum number of level electrodes or conductive probes that can be connected to the device.

Ethernet Port Count

Number of integrated physical Ethernet communication ports.

RS-485 Port Count

Number of integrated physical RS-485 communication interfaces.

USB Port Count

Number of integrated physical USB ports provided by the product, including charging, data, communication or programming ports.

Minimum ROCOF Evaluation Cycle Countcycles

Minimum number of electrical cycles used for ROCOF evaluation where configurable or specified by the manufacturer.

Maximum ROCOF Evaluation Cycle Countcycles

Maximum number of electrical cycles used for ROCOF evaluation where configurable or specified by the manufacturer.

Insulation Response Value Count

Number of independently usable insulation-resistance response values or alarm thresholds.

Temperature Sensor Input Count

Number of independently connectable temperature sensor or thermistor measuring circuits.

Level Control Point Count

Number of distinct liquid-level switching points that can be evaluated by the device, typically one or two.

Level Electrode Count

Maximum number of conductive measuring electrodes directly connected to one level monitoring device.

Maximum Simultaneously Monitored Quantity Count

Maximum number of different measured quantities that can be evaluated simultaneously.

Parameter Set Count

Number of independent parameter or setting sets that can be stored in the device.

Maximum Simultaneous Monitoring Functions

Maximum number of monitoring functions that can operate simultaneously in one device configuration.

Materials and Finish5
Color

Primary visually perceived colour of the product's external surface.

RAL Color

Designation of the product's primary surface colour according to the RAL colour system.

Surface Finish

Type of final surface finish of the product determining its appearance and service properties.

Material

Primary material from which the product is manufactured.

Material Grade

Grade, alloy, class, or technical designation of the product's primary material.

Mounting and Installation5
DIN Rail Type

Profile type of the DIN rail installed in the product or specified for compatible mounting.

Mounting Type

Installation arrangement permitted by the product design, such as wall-mounted, flush-mounted, floor-mounted, or another specified mounting type.

Mounting Method

Method used to mechanically secure the product to a support, surface, or load-bearing structure.

DIN Rail Mounting Supported

Indicates whether the design provides for mounting equipment on a DIN rail.

Direct Device Mounting Supported

Indicates whether equipment may be mounted directly to the mounting surface without an intermediate DIN rail.

Electrical Parameters398
Rated Insulation VoltageV

Voltage with reference to which the product's insulation clearances and dielectric properties are specified.

Rated Impulse Withstand VoltagekV

Peak value of an impulse voltage of specified waveform that the product insulation must withstand without breakdown.

Dielectric Test VoltageV

Test voltage applied to verify the dielectric strength of the product insulation.

Minimum Insulation ResistanceMΩ

Minimum permissible insulation resistance between the specified electrically separated parts.

Overvoltage Category

Category characterizing the expected level of impulse overvoltages at the product's point of use.

Pollution Degree

Degree of pollution of the surrounding microenvironment considered when selecting insulation distances and product characteristics.

Insulation Type

Type of electrical insulation used, considered in terms of its protective function and construction.

Electrical Protection Class

Class of protection against electric shock determined by the product design and protective connection method.

Relay Contact Maximum Switching PowerW

Maximum manufacturer-declared active power that may be switched by the relay-output contacts.

Response Timens

Manufacturer-declared response time of the relevant protective function of the product to a surge impulse.

Temperature Sensor Connection Types

Supported wiring arrangements for resistive temperature sensors, such as 2-wire, 3-wire or 4-wire connection.

Monitoring Supply Mode

Relationship between the monitored measuring circuit and the electrical supply required for operation of the monitoring or indication function.

Monitoring Threshold Reference Mode

Defines whether a monitoring threshold is specified as an absolute measured value or relative to a nominal or measuring-range value.

Monitored Voltage Current Type

Current type of the monitored voltage measuring circuit: AC, DC or AC/DC.

Minimum Monitored VoltageV

Lower limit of the manufacturer-declared voltage measuring range.

Maximum Monitored VoltageV

Upper limit of the manufacturer-declared voltage measuring range.

Voltage Measurement Accuracy%

Manufacturer-declared accuracy of voltage measurement where expressed as a single percentage value.

Voltage Threshold Setting Accuracy%

Manufacturer-declared accuracy of the configured voltage monitoring threshold.

Voltage Monitoring Repeat Accuracy%

Repeat accuracy of voltage threshold detection or switching under constant conditions.

Voltage Monitoring Accuracy versus Supply Variation%

Maximum voltage-monitoring error attributable to variation of the device supply voltage within its declared tolerance.

Voltage Monitoring Temperature Coefficient%/K

Change of voltage-monitoring accuracy per degree of temperature variation.

Monitored Voltage Input ResistanceΩ

Electrical input resistance of the monitored voltage measuring circuit.

Minimum Monitored Voltage FrequencyHz

Minimum AC measuring-signal frequency supported by the voltage monitoring function.

Maximum Monitored Voltage FrequencyHz

Maximum AC measuring-signal frequency supported by the voltage monitoring function.

Minimum Rated Monitored Voltage FrequencyHz

Lower limit of the rated measuring-signal frequency range for which nominal voltage-monitoring characteristics are specified.

Maximum Rated Monitored Voltage FrequencyHz

Upper limit of the rated measuring-signal frequency range for which nominal voltage-monitoring characteristics are specified.

Maximum Monitored Voltage Pulse OverloadV

Maximum short-duration voltage that the measuring input can withstand without damage under the stated pulse duration.

Monitored Voltage Pulse Overload Durations

Duration associated with the manufacturer-declared pulse overload capability of the monitored voltage input.

Monitored Voltage Continuous Input LimitV

Maximum voltage that may be continuously applied to the monitored voltage input under manufacturer-declared conditions.

Neutral Monitoring Method

Method used to detect interruption or abnormal condition of the neutral conductor.

Minimum Phase Failure Threshold Ratio%

Minimum configurable phase-failure detection threshold expressed as a percentage of the applicable nominal or reference phase voltage.

Maximum Phase Failure Threshold Ratio%

Maximum configurable phase-failure detection threshold expressed as a percentage of the applicable nominal or reference phase voltage.

Maximum Regenerative Voltage Ratio for Phase Failure Detection%

Maximum regenerative or back-fed voltage, expressed relative to the monitored line voltage, for which reliable phase-failure detection is declared.

Minimum Phase Asymmetry Threshold%

Minimum configurable voltage-asymmetry or voltage-unbalance threshold.

Maximum Phase Asymmetry Threshold%

Maximum configurable voltage-asymmetry or voltage-unbalance threshold.

Phase Asymmetry Measurement Accuracy%

Manufacturer-declared accuracy of phase-voltage asymmetry or voltage-unbalance evaluation.

Phase Asymmetry Repeat Accuracy%

Repeat accuracy of phase-asymmetry threshold detection under constant reference conditions.

Nominal Monitored FrequencyHz

Nominal frequency of the electrical source or circuit monitored by the device.

Minimum Monitored FrequencyHz

Lower limit of the manufacturer-declared frequency measurement range.

Maximum Monitored FrequencyHz

Upper limit of the manufacturer-declared frequency measurement range.

Frequency Measurement AccuracyHz

Manufacturer-declared absolute accuracy of frequency measurement.

Frequency Threshold Setting AccuracyHz

Manufacturer-declared absolute accuracy of the configured frequency monitoring threshold.

Frequency Monitoring Repeat AccuracyHz

Repeat accuracy of frequency threshold detection under constant reference conditions.

Frequency Threshold Setting ResolutionHz

Smallest manufacturer-supported adjustment increment for an absolute frequency threshold.

Relative Frequency Threshold Setting Resolution%

Smallest manufacturer-supported adjustment increment when the frequency threshold is specified relative to nominal frequency.

Minimum ROCOF ThresholdHz/s

Minimum configurable rate-of-change-of-frequency threshold.

Maximum ROCOF ThresholdHz/s

Maximum configurable rate-of-change-of-frequency threshold.

Monitored Current Type

Current type of the monitored measuring circuit: AC, DC or AC/DC.

Current Evaluation Quantities

Types of current quantities evaluated by the monitoring device, for example RMS, active-current component or apparent current.

Nominal Monitored CurrentA

Nominal current used as the reference value for current monitoring and relative threshold settings.

Minimum Monitored CurrentA

Lower limit of the manufacturer-declared current measuring range.

Maximum Monitored CurrentA

Upper limit of the manufacturer-declared current measuring range.

Current Measurement Accuracy%

Manufacturer-declared relative accuracy of current measurement where expressed as a percentage.

Current Threshold Setting Accuracy%

Manufacturer-declared accuracy of the configured current monitoring threshold.

Current Monitoring Repeat Accuracy%

Repeat accuracy of current threshold detection under constant reference conditions.

Current Monitoring Temperature Coefficient%/K

Change of current monitoring accuracy per degree of temperature variation.

Monitored Current Input ResistanceΩ

Electrical resistance of the current measuring input.

Minimum Monitored Current FrequencyHz

Minimum AC current frequency supported by the measuring input.

Maximum Monitored Current FrequencyHz

Maximum AC current frequency supported by the measuring input.

Continuous Current Input LimitA

Maximum current that may be continuously applied to the measuring input without exceeding manufacturer-declared limits.

Maximum Current Input OverloadA

Maximum short-duration current that the measuring input can withstand.

Current Input Overload Durations

Duration associated with the declared short-duration current input overload capability.

Minimum Current HysteresisA

Minimum configurable current hysteresis expressed as an absolute current difference.

Maximum Current HysteresisA

Maximum configurable current hysteresis expressed as an absolute current difference.

Current Measurement Connection Method

Supported methods for connecting the monitored current to the measuring device.

Minimum Current Transformer Ratio

Minimum configurable primary-to-secondary current transformer ratio.

Maximum Current Transformer Ratio

Maximum configurable primary-to-secondary current transformer ratio.

Current Input BurdenVA

Apparent-power burden presented by the measuring input to an external current transformer under manufacturer-declared conditions.

Minimum Shunt Input VoltageV

Minimum supported measuring voltage across an external current shunt. UI may display the value in mV.

Maximum Shunt Input VoltageV

Maximum supported measuring voltage across an external current shunt. UI may display the value in mV.

Power Measurement Scope

Defines whether electrical power is evaluated as a total system value, per phase, or both.

Measured Power Quantities

Electrical power quantities measured or calculated by the device.

Supported Power Flow Directions

Power-flow directions that can be measured or evaluated by the product.

Minimum Active Power MeasurementW

Lower limit of the manufacturer-declared active-power measuring range.

Maximum Active Power MeasurementW

Upper limit of the manufacturer-declared active-power measuring range.

Active Power Measurement Accuracy%

Manufacturer-declared relative accuracy of active-power measurement.

Minimum Active Power HysteresisW

Minimum configurable active-power hysteresis expressed as an absolute power difference.

Maximum Active Power HysteresisW

Maximum configurable active-power hysteresis expressed as an absolute power difference.

Minimum Reverse Active Power ThresholdW

Minimum configurable active-power threshold for detection of reverse or exported power flow.

Maximum Reverse Active Power ThresholdW

Maximum configurable active-power threshold for detection of reverse or exported power flow.

Minimum Reactive Power Measurementvar

Lower limit of the manufacturer-declared reactive-power measuring range.

Maximum Reactive Power Measurementvar

Upper limit of the manufacturer-declared reactive-power measuring range.

Reactive Power Measurement Accuracy%

Manufacturer-declared relative accuracy of reactive-power measurement.

Minimum Reactive Power Thresholdvar

Minimum configurable reactive-power monitoring threshold.

Maximum Reactive Power Thresholdvar

Maximum configurable reactive-power monitoring threshold.

Minimum Apparent Power MeasurementVA

Lower limit of the manufacturer-declared apparent-power measuring range.

Maximum Apparent Power MeasurementVA

Upper limit of the manufacturer-declared apparent-power measuring range.

Apparent Power Measurement Accuracy%

Manufacturer-declared relative accuracy of apparent-power measurement.

Minimum Apparent Power ThresholdVA

Minimum configurable apparent-power monitoring threshold.

Maximum Apparent Power ThresholdVA

Maximum configurable apparent-power monitoring threshold.

Power Factor Load Characteristics

Inductive or capacitive power-factor regions that the device can distinguish or monitor.

Minimum Power Factor Measurement

Lower limit of the manufacturer-declared power-factor measuring range.

Maximum Power Factor Measurement

Upper limit of the manufacturer-declared power-factor measuring range.

Power Factor Measurement Accuracy

Manufacturer-declared absolute accuracy of power-factor measurement expressed as a cos φ value difference.

Power Factor Threshold Setting Resolution

Smallest manufacturer-supported adjustment increment for the power-factor threshold.

Active Current Measurement Supported

Indicates support for measurement of the active or resistive current component Ires, distinct from RMS current.

Minimum Active Current MeasurementA

Lower limit of the manufacturer-declared active-current Ires measuring range.

Maximum Active Current MeasurementA

Upper limit of the manufacturer-declared active-current Ires measuring range.

Minimum Active Current HysteresisA

Minimum configurable hysteresis for active-current Ires monitoring.

Maximum Active Current HysteresisA

Maximum configurable hysteresis for active-current Ires monitoring.

Minimum Monitored System VoltageV

Lower limit of the nominal voltage range of the electrical system for which monitoring is supported.

Maximum Monitored System VoltageV

Upper limit of the nominal voltage range of the electrical system for which monitoring is supported.

Minimum Monitored System FrequencyHz

Minimum frequency of the monitored AC or AC/DC system supported by the insulation monitoring function.

Maximum Monitored System FrequencyHz

Maximum frequency of the monitored AC or AC/DC system supported by the insulation monitoring function.

Minimum Insulation Resistance MeasurementΩ

Lower limit of the insulation-resistance measuring range of the monitoring device.

Maximum Insulation Resistance MeasurementΩ

Upper limit of the insulation-resistance measuring range of the monitoring device.

Minimum Insulation Response ValueΩ

Minimum configurable insulation-resistance response value Ran.

Maximum Insulation Response ValueΩ

Maximum configurable insulation-resistance response value Ran.

Insulation Response Relative Uncertainty%

Manufacturer-declared relative uncertainty of the insulation-resistance response value.

Insulation Response Hysteresis Ratio%

Percentage component of the insulation-resistance response hysteresis.

Insulation Response Hysteresis ResistanceΩ

Absolute resistance component added to the insulation-resistance response hysteresis where declared by the manufacturer.

Maximum Insulation Response Times

Maximum manufacturer-declared response time of the insulation monitoring function under the specified resistance and system-capacitance conditions.

Maximum Insulation Measuring VoltageV

Maximum measuring or test voltage injected into the monitored system by the insulation monitoring function.

Minimum Internal DC ResistanceΩ

Minimum internal DC resistance of the insulation monitoring measuring circuit.

Minimum Internal Measuring ImpedanceΩ

Minimum internal measuring impedance of the insulation monitoring circuit at the manufacturer-declared reference frequency.

Maximum Permissible Extraneous DC VoltageV

Maximum extraneous DC voltage that may be present in the monitored system without exceeding the declared limits of the insulation monitoring device.

Maximum Locating CurrentA

Maximum locating current generated or supported for insulation fault location.

Maximum Locating VoltageV

Maximum locating voltage generated or supported for insulation fault location.

Minimum Temperature Measurement°C

Lower limit of the manufacturer-declared temperature measuring range.

Maximum Temperature Measurement°C

Upper limit of the manufacturer-declared temperature measuring range.

Absolute Temperature Measurement AccuracyK

Manufacturer-declared absolute temperature measurement accuracy expressed as a temperature difference.

Relative Temperature Measurement Accuracy%

Manufacturer-declared temperature measurement accuracy expressed as a percentage of measuring range or full scale.

Temperature Accuracy versus Supply Variation%/V

Change of temperature measuring accuracy caused by variation of the control supply voltage.

Temperature Measurement Accuracy Temperature Coefficient%/K

Change of measuring accuracy per degree of ambient temperature variation.

Temperature Monitoring Repeat Accuracy%

Repeat accuracy of temperature threshold detection under constant reference conditions.

Temperature Threshold Setting ResolutionK

Smallest manufacturer-supported adjustment increment for a temperature threshold.

Maximum Temperature Sensor Circuit CurrentA

Maximum measuring or excitation current supplied through a connected temperature sensor circuit.

Maximum Temperature Sensor Circuit VoltageV

Maximum manufacturer-declared voltage occurring in the temperature sensor measuring circuit.

Maximum PTC Total Cold ResistanceΩ

Maximum permissible total resistance of series-connected PTC sensors in their cold state.

PTC Trip ResistanceΩ

PTC sensor-circuit resistance at which the protection output changes to the overtemperature trip state.

PTC Reset ResistanceΩ

PTC sensor-circuit resistance below which reset or return to the normal state becomes possible.

PTC Short-Circuit Trip ResistanceΩ

Sensor-circuit resistance below which the device identifies a PTC sensor-circuit short circuit and enters the fault state.

PTC Short-Circuit Reset ResistanceΩ

Sensor-circuit resistance above which the PTC short-circuit fault condition is cleared or reset becomes possible.

Level Sensor Input Types

Electrical sensor or probe interface types accepted by the level monitoring device.

Level Electrode Configurations

Supported arrangements of conductive electrodes used for single-level or two-level monitoring.

Minimum Level Response SensitivityΩ

Minimum selectable resistance threshold of the conductive level sensing circuit.

Maximum Level Response SensitivityΩ

Maximum selectable resistance threshold of the conductive level sensing circuit.

Level Resistance Measurement Accuracy%

Manufacturer-declared accuracy of the resistance-based level sensing function.

Level Measurement Temperature Coefficient%/K

Change of resistance-based level measurement accuracy per degree of ambient temperature variation.

Probe Excitation Current Type

Current waveform used by the level monitoring device to excite conductive probes or electrodes.

Maximum Probe Excitation VoltageV

Maximum manufacturer-declared measuring voltage applied to the level electrodes.

Maximum Probe Excitation CurrentA

Maximum manufacturer-declared measuring current flowing through the level sensing probes.

Probe Excitation FrequencyHz

Frequency of the AC or modulated measuring signal applied to conductive level probes where specified.

Maximum Probe Cable CapacitancenF

Maximum permissible total capacitance of the level probe connection cable for the applicable sensitivity range.

Level Sensor Supply VoltageV

Nominal auxiliary voltage supplied by the monitoring device to an external level sensor.

Maximum Level Sensor Supply CurrentA

Maximum output current available from the integrated external level sensor supply.

Supply Current Type

Type of electrical current for which the product's main supply circuit is intended.

Rated VoltageV

Voltage value assigned to the product by the manufacturer for specified application conditions and characteristics.

Rated AC VoltageV

Rated RMS value of alternating voltage assigned to the product by the manufacturer.

Rated DC VoltageV

Rated direct voltage assigned to the product by the manufacturer.

Rated FrequencyHz

AC frequency assigned to the product for normal operating conditions.

Auxiliary Supply VoltageV

Rated external auxiliary supply voltage required for the product's active functions.

Auxiliary Supply Type

Type of current and source used for the product's auxiliary supply.

Maximum Power DissipationW

Maximum thermal power loss that the product can dissipate under specified conditions.

Power Dissipation at Rated CurrentW

Thermal power loss of the product or current-carrying system at rated current.

Supported Conductor Material

Conductor materials for which the specified terminals and connection methods are designed.

Conductor Connection Type

Conductor connection methods supported by the specified terminals or connection elements.

Terminal Tightening TorqueNm

Tightening torque specified by the manufacturer for a screw or bolted terminal connection.

Monitoring Functions

Electrical or physical monitoring functions provided by the device, such as overvalue, undervalue, window, phase, frequency, current, power, insulation, temperature or level monitoring.

Measurement Principle

Electrical measurement principle used for evaluation of the monitored signal, such as true RMS, RMS, average-value or direct-value measurement.

Measuring Input Type

Physical or electrical input technology used for acquisition of the monitored quantity, for example direct voltage, direct current, current transformer, resistance sensor, thermistor or conductive probe.

Measured Signal Current Type

Current type accepted by the measuring input, such as AC, DC or AC/DC.

Measuring Input Count

Number of independent physical measuring inputs provided by the device.

Galvanically Isolated Measuring Input

Indicates whether the measuring input is galvanically isolated from the supply, output or other relevant circuits.

Self-Powered from Measured Circuit

Indicates that the monitoring device derives its operating power directly from the measured circuit and does not require a separate auxiliary supply.

Minimum Measurement FrequencyHz

Minimum signal frequency accepted by the measuring circuit for the declared monitoring or measurement function.

Maximum Measurement FrequencyHz

Maximum signal frequency accepted by the measuring circuit for the declared monitoring or measurement function.

Measuring Input ResistanceΩ

Manufacturer-declared electrical resistance of the measuring input where applicable.

Measurement Accuracy%

Manufacturer-declared accuracy of the measured value under the specified reference conditions.

Threshold Setting Accuracy%

Manufacturer-declared accuracy or tolerance of the configured monitoring threshold.

Repeat Accuracy%

Manufacturer-declared repeatability of switching, alarm or monitoring operation under unchanged reference conditions.

Temperature Coefficient%/K

Manufacturer-declared change of measuring or switching accuracy per unit change of ambient temperature.

Monitoring Threshold Count

Number of independently usable monitoring, switching or alarm thresholds provided by the device.

Threshold Setting Methods

Methods available for setting monitoring thresholds, such as potentiometer, rotary selector, DIP switch, buttons, software or NFC configuration.

Adjustable Response Delay

Indicates that the intentional delay between detection of a monitored fault condition and output operation can be adjusted.

Minimum Response Delays

Minimum configurable response delay between fault detection and monitoring output operation.

Maximum Response Delays

Maximum configurable response delay between fault detection and monitoring output operation.

Fixed Response Delays

Fixed manufacturer-declared intentional response delay where the monitoring device does not provide an adjustable delay.

Recovery Times

Time required for the monitoring function or output to recover after the monitored quantity has returned to the permissible range.

Power Failure Buffering Times

Maximum supply interruption duration that can be tolerated without loss of the relevant operating or monitoring state.

Window Monitoring Supported

Indicates support for monitoring whether the measured value remains inside or outside a defined lower-to-upper threshold window.

Independent Upper and Lower Thresholds

Indicates that the upper and lower limits of a monitoring window can be configured independently.

Measurement Range Count

Number of discrete measurement ranges supported by the measuring input.

Selectable Measurement Range

Indicates that the measuring range can be selected or configured by the user.

Measurement Range Selection Method

Method used to select the active measuring range, such as automatic range selection, rotary control, DIP switch, wiring selection or software configuration.

Monitoring Output Operating Principle

Operating principle of the monitoring relay output with respect to normal and fault conditions, such as normally energized, normally de-energized or selectable behaviour.

Threshold Reference Mode

Defines whether monitoring thresholds are specified as absolute measured values, percentages of a nominal value or another manufacturer-defined reference.

Relay Operate Timems

Manufacturer-declared time from application of the control signal until the relay reaches its operated switching state.

Relay Release Timems

Manufacturer-declared time from removal of the control signal until the relay returns to its released switching state.

Contact Bounce Timems

Manufacturer-declared duration of mechanical contact bounce following relay contact operation.

Relay Contact Structure

Mechanical structure of an individual switching contact system, for example single, double or bifurcated contact.

Relay Contact Material

Electrical contact material or contact-material system used by the relay switching contacts.

Relay Contact Maximum Switching VoltageV

Maximum manufacturer-declared voltage that may be switched by the relay-output contacts.

Relay Contact Maximum Switching CurrentA

Maximum manufacturer-declared current that may be switched by the relay-output contacts.

Relay Contact Minimum Switching VoltageV

Minimum manufacturer-declared switching voltage for reliable operation of the relay contact.

Relay Contact Minimum Switching CurrentA

Minimum manufacturer-declared switching current for reliable relay-contact operation.

Relay Contact Limiting Continuous CurrentA

Maximum continuous current permitted through a closed relay contact under the manufacturer-declared conditions.

Relay Contact Maximum Inrush CurrentA

Maximum short-duration inrush current permitted through the relay switching contact.

Relay Contact Maximum AC Switching VoltageV

Maximum AC switching voltage of the relay output contact.

Relay Contact Maximum DC Switching VoltageV

Maximum DC switching voltage of the relay output contact.

Voltage Measurement Supported

Indicates whether the product can measure and provide electrical voltage values.

Nominal Monitored VoltageV

Nominal voltage of the electrical circuit whose voltage condition is monitored by the device.

Minimum Voltage Measurement RangeV

Lowest voltage that can be measured or monitored within the manufacturer-declared measuring range.

Maximum Voltage Measurement RangeV

Highest voltage that can be measured or monitored within the manufacturer-declared measuring range.

Voltage Measurement Reference

Electrical voltage relationships measured by the device, for example line-to-line or line-to-neutral.

Adjustable Voltage Monitoring Threshold

Indicates whether one or more voltage-monitoring threshold values can be adjusted.

Maximum Voltage Fault Detection Times

Maximum intrinsic detection or response time for an overvoltage or undervoltage condition, excluding intentionally configured output delay where specified separately.

Voltage Measuring Input Short-Time OverloadV

Maximum short-duration voltage that the measuring input can withstand without damage under manufacturer-declared conditions.

Voltage Measuring Input Short-Time Overload Durations

Maximum duration associated with the declared short-time voltage overload capability of the measuring input.

Voltage Measuring Input Continuous OverloadV

Maximum voltage that may be continuously applied to the measuring input without damage under manufacturer-declared conditions.

Minimum Overvoltage ThresholdV

Minimum configurable absolute voltage threshold for overvoltage monitoring.

Maximum Overvoltage ThresholdV

Maximum configurable absolute voltage threshold for overvoltage monitoring.

Minimum Relative Overvoltage Threshold%

Minimum configurable overvoltage threshold expressed relative to the applicable nominal or reference voltage.

Maximum Relative Overvoltage Threshold%

Maximum configurable overvoltage threshold expressed relative to the applicable nominal or reference voltage.

Minimum Undervoltage ThresholdV

Minimum configurable absolute voltage threshold for undervoltage monitoring.

Maximum Undervoltage ThresholdV

Maximum configurable absolute voltage threshold for undervoltage monitoring.

Minimum Relative Undervoltage Threshold%

Minimum configurable undervoltage threshold expressed relative to the applicable nominal or reference voltage.

Maximum Relative Undervoltage Threshold%

Maximum configurable undervoltage threshold expressed relative to the applicable nominal or reference voltage.

Number of Phases

Number of phases of the electrical system for which the product is designed to be connected or used.

Conductor System

Configuration of live and neutral conductors of the electrical system supported by the product.

Phase Loss Detection Threshold Ratio%

Voltage level relative to the nominal or reference voltage below which a phase is considered lost.

Maximum Regenerative Feedback for Phase Loss Detection%

Maximum regenerated or feedback voltage relative to the normal phase voltage at which reliable phase loss detection is manufacturer-declared.

Maximum Phase Loss Detection Times

Maximum intrinsic time required to detect loss of a monitored phase.

Expected Phase Sequence

Phase sequence regarded by the monitoring function as the correct sequence, where this is manufacturer-declared or configurable.

Maximum Phase Sequence Detection Times

Maximum intrinsic time required to detect an incorrect phase sequence.

Voltage Unbalance Measurement Supported

Indicates whether voltage unbalance measurement or calculation is supported.

Minimum Voltage Unbalance Threshold%

Minimum configurable voltage unbalance or phase asymmetry threshold.

Maximum Voltage Unbalance Threshold%

Maximum configurable voltage unbalance or phase asymmetry threshold.

Maximum Phase Asymmetry Detection Times

Maximum intrinsic detection time for a phase or voltage asymmetry condition.

Adjustable Neutral Conductor Monitoring

Indicates that neutral conductor monitoring parameters can be enabled, disabled or adjusted by the user.

Frequency Measurement Supported

Indicates whether the product can measure and provide electrical network frequency values.

Adjustable Frequency Monitoring Threshold

Indicates whether one or more frequency-monitoring threshold values can be adjusted.

Minimum FrequencyHz

Lower limit of the electrical network or signal frequency at which product operation is permitted.

Maximum FrequencyHz

Upper limit of the electrical network or signal frequency at which product operation is permitted.

Maximum Frequency Fault Detection Times

Maximum intrinsic detection or response time for an underfrequency or overfrequency condition.

Minimum Underfrequency ThresholdHz

Minimum configurable absolute threshold for underfrequency monitoring.

Maximum Underfrequency ThresholdHz

Maximum configurable absolute threshold for underfrequency monitoring.

Minimum Overfrequency ThresholdHz

Minimum configurable absolute threshold for overfrequency monitoring.

Maximum Overfrequency ThresholdHz

Maximum configurable absolute threshold for overfrequency monitoring.

Minimum Relative Underfrequency Threshold%

Minimum configurable underfrequency threshold expressed relative to the nominal or reference frequency.

Maximum Relative Underfrequency Threshold%

Maximum configurable underfrequency threshold expressed relative to the nominal or reference frequency.

Minimum Relative Overfrequency Threshold%

Minimum configurable overfrequency threshold expressed relative to the nominal or reference frequency.

Maximum Relative Overfrequency Threshold%

Maximum configurable overfrequency threshold expressed relative to the nominal or reference frequency.

Minimum Frequency HysteresisHz

Minimum configurable absolute hysteresis for frequency threshold monitoring.

Maximum Frequency HysteresisHz

Maximum configurable absolute hysteresis for frequency threshold monitoring.

Current Measurement Supported

Indicates whether the product can measure and provide electrical current values.

Minimum Current Measurement RangeA

Lowest current that can be measured or monitored within the manufacturer-declared measuring range.

Maximum Current Measurement RangeA

Highest current that can be measured or monitored within the manufacturer-declared measuring range.

Current Transformer Input Supported

Indicates that the measuring circuit supports connection through an external current transformer.

Configurable Current Transformer Ratio

Indicates that the current transformer ratio used for measurement scaling can be configured in the device.

Minimum Current Transformer Primary Current SettingA

Minimum configurable primary current value used for current transformer scaling.

Maximum Current Transformer Primary Current SettingA

Maximum configurable primary current value used for current transformer scaling.

Supported Current Transformer Secondary Currents

Standard secondary current ratings of external current transformers supported by the measuring input.

Current Measuring Input Short-Time OverloadA

Maximum short-duration current that the measuring input can withstand without damage under manufacturer-declared conditions.

Current Measuring Input Short-Time Overload Durations

Maximum duration associated with the declared short-time current overload capability of the measuring input.

Current Measuring Input Continuous OverloadA

Maximum current that may be continuously applied to the measuring input without damage under manufacturer-declared conditions.

Minimum / Maximum Measurement Supported

Indicates whether the product stores or provides minimum and maximum values of measured quantities.

Adjustable Current Monitoring Threshold

Indicates that one or more current monitoring thresholds can be adjusted by the user.

Maximum Current Fault Detection Times

Maximum intrinsic detection time for an overcurrent or undercurrent condition, excluding an intentionally configured response delay.

Minimum Overcurrent ThresholdA

Minimum configurable absolute current threshold for overcurrent monitoring.

Maximum Overcurrent ThresholdA

Maximum configurable absolute current threshold for overcurrent monitoring.

Minimum Relative Overcurrent Threshold%

Minimum configurable overcurrent threshold expressed relative to the applicable nominal or reference current.

Maximum Relative Overcurrent Threshold%

Maximum configurable overcurrent threshold expressed relative to the applicable nominal or reference current.

Minimum Undercurrent ThresholdA

Minimum configurable absolute current threshold for undercurrent monitoring.

Maximum Undercurrent ThresholdA

Maximum configurable absolute current threshold for undercurrent monitoring.

Minimum Relative Undercurrent Threshold%

Minimum configurable undercurrent threshold expressed relative to the applicable nominal or reference current.

Maximum Relative Undercurrent Threshold%

Maximum configurable undercurrent threshold expressed relative to the applicable nominal or reference current.

Current Unbalance Measurement Supported

Indicates whether current unbalance measurement or calculation is supported.

Active Current Monitoring Supported

Indicates support for monitoring the active component of current derived from current and phase relationship.

Minimum Active Current ThresholdA

Minimum configurable threshold for active-current monitoring.

Maximum Active Current ThresholdA

Maximum configurable threshold for active-current monitoring.

Power Measurement Supported

Indicates whether measurement of active, reactive, or apparent electrical power is supported.

Adjustable Power Monitoring Threshold

Indicates that one or more power monitoring thresholds can be adjusted by the user.

Active Power Measurement Supported

Indicates that active electrical power is measured or calculated by the device.

Reactive Power Measurement Supported

Indicates that reactive electrical power is measured or calculated by the device.

Apparent Power Measurement Supported

Indicates that apparent electrical power is measured or calculated by the device.

Minimum Active Power Measurement RangeW

Lowest active power value within the manufacturer-declared measurement range.

Maximum Active Power Measurement RangeW

Highest active power value within the manufacturer-declared measurement range.

Minimum Active Power ThresholdW

Minimum configurable absolute active-power monitoring threshold.

Maximum Active Power ThresholdW

Maximum configurable absolute active-power monitoring threshold.

Reverse Power Monitoring Supported

Indicates support for detection or monitoring of active power flowing in the reverse direction.

Power Direction Monitoring Supported

Indicates that the device can distinguish and monitor the direction of active power flow.

Maximum Active Power Fault Detection Times

Maximum intrinsic time required to detect an active-power threshold violation.

Power Factor Measurement Supported

Indicates that the electrical power factor is measured or calculated by the device.

Adjustable Power Factor Monitoring Threshold

Indicates that one or more power-factor monitoring thresholds can be adjusted by the user.

Minimum Power Factor Measurement Range

Lowest power-factor value within the manufacturer-declared measurement range.

Maximum Power Factor Measurement Range

Highest power-factor value within the manufacturer-declared measurement range.

Minimum Power Factor Threshold

Minimum configurable threshold value for power-factor monitoring.

Maximum Power Factor Threshold

Maximum configurable threshold value for power-factor monitoring.

Leading / Lagging Power Factor Detection Supported

Indicates that the device can distinguish between leading and lagging power-factor conditions.

Maximum Power Factor Fault Detection Times

Maximum intrinsic time required to detect a power-factor threshold violation.

Minimum Power Factor Hysteresis

Minimum configurable absolute hysteresis of the power-factor monitoring threshold.

Maximum Power Factor Hysteresis

Maximum configurable absolute hysteresis of the power-factor monitoring threshold.

Supported Earthing Systems

Electrical network earthing systems with which the product may be used in the declared configuration.

Isolated Neutral Supported

Indicates whether the design permits the neutral busbar or conductor to be insulated from the enclosure.

Functional Earth Connection

Indicates whether a separate functional earth connection is provided that does not replace the PE protective connection.

Insulation Resistance Measurement Supported

Indicates that the device measures insulation resistance of the monitored electrical system against earth.

Minimum Insulation Resistance Measurement RangeMΩ

Lowest insulation resistance value within the manufacturer-declared measurement range of the insulation monitoring function.

Maximum Insulation Resistance Measurement RangeMΩ

Highest insulation resistance value within the manufacturer-declared measurement range of the insulation monitoring function.

Adjustable Insulation Alarm Threshold

Indicates that the insulation resistance alarm or response threshold can be adjusted by the user.

Minimum Insulation Alarm ThresholdMΩ

Minimum configurable insulation resistance alarm or response threshold.

Maximum Insulation Alarm ThresholdMΩ

Maximum configurable insulation resistance alarm or response threshold.

Insulation Warning Threshold Supported

Indicates that a separate insulation resistance warning or pre-alarm threshold is available in addition to the main alarm threshold.

Minimum Insulation Warning ThresholdMΩ

Minimum configurable insulation resistance warning or pre-alarm threshold.

Maximum Insulation Warning ThresholdMΩ

Maximum configurable insulation resistance warning or pre-alarm threshold.

Maximum Insulation Fault Detection Times

Maximum manufacturer-declared intrinsic time required to detect an insulation resistance fault under specified system conditions.

Insulation Measurement VoltageV

Manufacturer-declared measuring voltage generated or applied by the insulation monitoring circuit.

Maximum Insulation Measurement CurrentA

Maximum measuring current generated by the insulation monitoring circuit under manufacturer-declared conditions.

Insulation Monitor Internal DC ResistanceMΩ

Manufacturer-declared internal DC resistance of the insulation monitoring measuring circuit relative to the monitored system.

Insulation Measurement Method

Manufacturer-declared measuring principle or test-signal method used to determine insulation resistance in the monitored system.

Maximum System Leakage CapacitanceµF

Maximum total system leakage capacitance to earth for which the insulation monitoring function is manufacturer-declared to operate correctly.

System Leakage Capacitance Measurement Supported

Indicates that the device can determine or display the system leakage capacitance to earth in addition to insulation resistance.

Maximum System Leakage Capacitance Measurement RangeµF

Upper limit of the manufacturer-declared system leakage capacitance measurement range.

Supported Insulation Monitoring System Types

Types of unearthed or impedance-earthed electrical systems for which insulation monitoring is manufacturer-declared, such as AC, DC or combined AC/DC systems.

Energized System Insulation Monitoring Supported

Indicates that insulation resistance can be continuously monitored while the electrical system is energized and operating.

De-Energized System Insulation Monitoring Supported

Indicates support for insulation monitoring or insulation fault detection while the monitored load or system is de-energized.

Positive / Negative Insulation Measurement Supported

Indicates that insulation resistance can be evaluated separately for the positive and negative conductors of a DC system.

Insulation Fault Polarity Detection Supported

Indicates that the device can identify whether an insulation fault is associated with the positive or negative side of a DC system.

Insulation Monitoring Coupling Device Required

Indicates that a separate coupling device is required between the insulation monitor and the monitored electrical system.

External Insulation Monitoring Coupling Device Supported

Indicates compatibility with an external manufacturer-specified coupling device used to extend the monitored system voltage range.

Maximum System Voltage with Coupling DeviceV

Maximum monitored system voltage achievable when using the manufacturer-specified insulation monitoring coupling device.

Analog Input Count

Number of integrated analogue input channels.

Analog Input Types

Analogue signal, sensor or resistance input types supported by the product.

Analog Input Resolutionbit

Resolution in bits of the analogue-to-digital conversion used for analogue inputs.

Minimum Temperature Measurement Range°C

Lowest temperature that can be measured by the temperature monitoring input under manufacturer-declared conditions.

Maximum Temperature Measurement Range°C

Highest temperature that can be measured by the temperature monitoring input under manufacturer-declared conditions.

Adjustable Temperature Monitoring Threshold

Indicates that one or more temperature monitoring thresholds can be adjusted by the user.

Minimum Overtemperature Threshold°C

Minimum configurable threshold for overtemperature monitoring.

Maximum Overtemperature Threshold°C

Maximum configurable threshold for overtemperature monitoring.

Minimum Undertemperature Threshold°C

Minimum configurable threshold for undertemperature monitoring.

Maximum Undertemperature Threshold°C

Maximum configurable threshold for undertemperature monitoring.

Minimum Temperature HysteresisK

Minimum configurable temperature hysteresis associated with a monitoring threshold.

Maximum Temperature HysteresisK

Maximum configurable temperature hysteresis associated with a monitoring threshold.

Supported Thermocouple Types

Thermocouple characteristic types supported by the temperature measuring input, for example J, K, T, E, N, R, S or B.

Sensor Line Resistance Compensation Supported

Indicates that resistance of sensor wiring can be compensated automatically or by the measuring method.

Maximum Sensor Line ResistanceΩ

Maximum sensor lead or line resistance permitted for manufacturer-declared temperature measurement performance.

Temperature Sensor Excitation CurrentA

Measurement or excitation current supplied by the device to a resistive temperature sensor where applicable.

Temperature Sampling Timems

Time interval used by the temperature measuring circuit to acquire or update the measured temperature.

Cold Junction Compensation Supported

Indicates support for cold-junction compensation when thermocouple inputs are used.

Minimum Temperature Difference ThresholdK

Minimum configurable threshold for temperature difference monitoring.

Maximum Temperature Difference ThresholdK

Maximum configurable threshold for temperature difference monitoring.

Thermistor Sensor Circuit Count

Number of independent thermistor sensor circuits evaluated by the protection relay.

Thermistor Trip ResistanceΩ

Sensor-circuit resistance at which the thermistor protection relay changes to the trip or overtemperature state.

Thermistor Reset ResistanceΩ

Sensor-circuit resistance below which reset or return from the thermistor trip state becomes possible.

Thermistor Short-Circuit Resistance ThresholdΩ

Sensor-circuit resistance below which the thermistor input is interpreted as a short circuit.

Maximum Thermistor Sensor Loop ResistanceΩ

Maximum permissible total cold-state resistance of the connected thermistor sensor circuit.

Maximum PTC Sensors in Series

Maximum number of PTC thermistor sensors permitted in series in one sensor circuit where declared by the manufacturer.

Thermistor Warning Resistance ThresholdΩ

Sensor-circuit resistance corresponding to operation of the thermistor warning or pre-alarm function.

Minimum Level Response ResistanceΩ

Lowest electrode-to-electrode or electrode-to-reference resistance within the manufacturer-declared sensitivity range.

Maximum Level Response ResistanceΩ

Highest electrode-to-electrode or electrode-to-reference resistance within the manufacturer-declared sensitivity range.

Adjustable Level Sensitivity

Indicates that the electrical sensitivity of the level measuring circuit can be adjusted for liquids with different conductivity.

Reference Probe Required

Indicates that a dedicated common or reference electrode is required for conductive level measurement.

Level Probe Measuring VoltageV

Manufacturer-declared electrical measuring voltage applied to the level probe circuit.

Level Probe Measuring Voltage Type

Electrical waveform or current type used by the level probe measuring circuit, such as AC, DC or pulsed measurement.

Maximum Level Probe Measuring CurrentA

Maximum measuring current flowing through the level probe circuit under manufacturer-declared conditions.

Level Probe Measuring Signal FrequencyHz

Frequency of the AC or alternating measuring signal applied to conductive level probes where specified.

Maximum Level Probe Cable Lengthmm

Maximum manufacturer-declared cable length between the level monitoring relay and the connected probe or electrode.

Maximum Measurement Cycle Timems

Maximum manufacturer-declared time required to complete one measurement and evaluation cycle of the monitoring function.

Connection Point Count

Total number of electrical connection points provided by the product.

Minimum Conductor Cross-Sectionmm²

Minimum conductor cross-section permitted by the connection system within its general conductor-size range.

Maximum Conductor Cross-Sectionmm²

Maximum conductor cross-section permitted by the connection system within its general conductor-size range.

Minimum Rigid Conductor Cross-Sectionmm²

Minimum rigid conductor cross-section permitted by an electrically and mechanically equivalent connection point.

Maximum Rigid Conductor Cross-Sectionmm²

Maximum rigid conductor cross-section permitted by an electrically and mechanically equivalent connection point.

Minimum Flexible Conductor Cross-Sectionmm²

Minimum flexible conductor cross-section permitted by the relevant connection point.

Maximum Flexible Conductor Cross-Sectionmm²

Maximum flexible conductor cross-section permitted by the relevant connection point.

Minimum Ferrule Cross-Section without Sleevemm²

Minimum flexible conductor cross-section with a ferrule without an insulating plastic collar permitted by the relevant connection point.

Maximum Ferrule Cross-Section without Sleevemm²

Maximum flexible conductor cross-section with a ferrule without an insulating plastic collar permitted by the relevant connection point.

Minimum Ferrule Cross-Section with Sleevemm²

Minimum flexible conductor cross-section with a ferrule and insulating plastic collar permitted by the relevant connection point.

Maximum Ferrule Cross-Section with Sleevemm²

Maximum flexible conductor cross-section with a ferrule and insulating plastic collar permitted by the relevant connection point.

Minimum TWIN Ferrule Conductor Cross-Sectionmm²

Minimum cross-section of each of two conductors connected simultaneously using a TWIN ferrule.

Maximum TWIN Ferrule Conductor Cross-Sectionmm²

Maximum cross-section of each of two conductors connected simultaneously using a TWIN ferrule.

Minimum Stripping Lengthmm

Minimum conductor stripping length specified by the manufacturer.

Maximum Stripping Lengthmm

Maximum conductor stripping length specified by the manufacturer.

Minimum Direct-Pluggable Rigid Conductor Cross-Sectionmm²

Minimum rigid conductor cross-section suitable for direct insertion into a compatible connection without prior actuation of the release mechanism.

Maximum Direct-Pluggable Rigid Conductor Cross-Sectionmm²

Maximum rigid conductor cross-section suitable for direct insertion into a compatible connection without prior actuation of the release mechanism.

Minimum Direct-Pluggable Ferrule Cross-Section without Sleevemm²

Minimum conductor cross-section with a ferrule without an insulating plastic collar suitable for direct insertion into a compatible connection.

Maximum Direct-Pluggable Ferrule Cross-Section without Sleevemm²

Maximum conductor cross-section with a ferrule without an insulating plastic collar suitable for direct insertion into a compatible connection.

Minimum Direct-Pluggable Ferrule Cross-Section with Sleevemm²

Minimum conductor cross-section with a ferrule and insulating plastic collar suitable for direct insertion into a compatible connection.

Maximum Direct-Pluggable Ferrule Cross-Section with Sleevemm²

Maximum conductor cross-section with a ferrule and insulating plastic collar suitable for direct insertion into a compatible connection.

Connection Actuation Type

Method or operator action used to open, actuate, or prepare the clamping mechanism before conductor insertion.

Conductor Release Method

Method used to release and remove a connected conductor from the connection point.

Direct Conductor Insertion Supported

Indicates whether an applicable conductor can be inserted directly without first opening the clamping mechanism using a tool or actuator.

Tool-Free Conductor Connection

Indicates whether normal conductor connection can be performed without using a separate hand tool.

Visual Connection Feedback

Indicates whether visual feedback is provided to confirm correct conductor connection or the intended operating state of the clamping mechanism.

Haptic Connection Feedback

Indicates whether haptic feedback is provided to confirm correct conductor connection or attainment of the intended operating state by the mechanism.

Conductor Release Tool Required

Indicates whether a separate tool is required to release the connected conductor.

Conductor Release Tool Type

Type, size, or designation of the tool declared by the manufacturer for actuating the conductor-release mechanism.

Terminal Screw Thread

Thread designation of the screw used in the conductor clamping mechanism, for example M2.5, M3, M4, or another manufacturer-declared designation.

Terminal Screw Head Type

Drive geometry of the screw head used to clamp the conductor in the terminal block.

Terminal Screwdriver Size

Size or designation of the screwdriver, bit, or other tool required to operate the terminal screw.

Minimum Terminal Tightening TorqueNm

Minimum tightening torque of the terminal screw, bolt, or nut declared by the manufacturer where a permissible range is specified.

Maximum Terminal Tightening TorqueNm

Maximum tightening torque of the terminal screw, bolt, or nut declared by the manufacturer where a permissible range is specified.

Minimum Cross-Section for Two Equal Rigid Conductorsmm²

Minimum cross-section of each of two equal rigid conductors that may be connected simultaneously to one clamping point.

Maximum Cross-Section for Two Equal Rigid Conductorsmm²

Maximum cross-section of each of two equal rigid conductors that may be connected simultaneously to one clamping point.

Minimum Cross-Section for Two Equal Flexible Conductorsmm²

Minimum cross-section of each of two equal flexible conductors that may be connected simultaneously to one clamping point.

Maximum Cross-Section for Two Equal Flexible Conductorsmm²

Maximum cross-section of each of two equal flexible conductors that may be connected simultaneously to one clamping point.

Minimum Cross-Section for Two Equal Conductors with Ferrules without Sleevesmm²

Minimum cross-section of each of two equal flexible conductors fitted with separate ferrules without insulating collars and permitted for joint connection to one clamping point.

Maximum Cross-Section for Two Equal Conductors with Ferrules without Sleevesmm²

Maximum cross-section of each of two equal flexible conductors fitted with separate ferrules without insulating collars and permitted for joint connection to one clamping point.

Protection and Safety12
Halogen-Free

Indicates whether the product material is classified as halogen-free according to the characteristics declared by the manufacturer.

IP Rating

Degree of enclosure protection against access to hazardous parts and ingress of solid objects and water, designated by the IP code.

IK Rating

Class of enclosure resistance to external mechanical impacts designated by the IK code.

Protection Against Direct Contact

Method or level of protection of the user against direct contact with hazardous live parts.

Finger-Safe

Indicates whether the design prevents finger access to hazardous live parts in the intended condition.

Touch-Safe

Indicates whether the design provides protection against accidental contact with hazardous live parts.

Flammability Class

Classification of a material according to its ability to ignite, sustain combustion, and cease burning under a specified test.

Glow-Wire Test Temperature°C

Temperature of the heated wire used when testing the material or product against an ignition source.

Input-to-Output Galvanic Isolation

Indicates that galvanic isolation is provided between the relevant electrical input and output circuits of the product.

Safe Isolation Present

Indicates that the manufacturer declares safe electrical separation between the relevant input and output circuits.

Dry-Run Protection Supported

Indicates that the level monitoring function can protect a pump or process against operation without sufficient liquid.

Overflow Protection Supported

Indicates that the level monitoring function can provide protection or alarm when the maximum permitted liquid level is reached.

Environmental Conditions18
Minimum Operating Temperature°C

Minimum ambient temperature at which normal operation of the product is permitted.

Maximum Operating Temperature°C

Maximum ambient temperature at which normal operation of the product is permitted.

Maximum 24-Hour Average Temperature°C

Maximum permissible average ambient temperature over a consecutive 24-hour period.

Minimum Storage Temperature°C

Minimum ambient temperature permitted during storage of the product while not in operation.

Maximum Storage Temperature°C

Maximum ambient temperature permitted during storage of the product while not in operation.

Minimum Transport Temperature°C

Minimum ambient temperature permitted during transportation of the product.

Maximum Transport Temperature°C

Maximum ambient temperature permitted during transportation of the product.

Temperature Derating Required

Indicates whether permissible electrical or thermal loading must be reduced as temperature changes.

Temperature Derating Start°C

Temperature above which the permissible product load must be reduced.

Temperature Derating Curve Available

Indicates whether the manufacturer has published the relationship between permissible product load and temperature.

Minimum Relative Humidity%

Minimum relative air humidity permitted for the declared operating or test condition.

Maximum Relative Humidity%

Maximum relative air humidity permitted for the declared operating or test condition.

Non-Condensing Humidity

Indicates whether the permissible humidity value applies only to non-condensing conditions.

Maximum Installation Altitudem

Maximum altitude above sea level at which the product may be installed without exceeding the declared conditions.

Altitude Derating Required

Indicates whether the permissible product load must be reduced as installation altitude increases.

Altitude Derating Startm

Altitude above sea level above which the permissible product load must be reduced.

Vibration Resistant

Indicates whether the product's resistance to vibration has been verified under the declared conditions.

Mechanical Shock Resistant

Indicates whether the product's resistance to short-duration mechanical shocks has been verified.

Included Equipment15
Documentation Included

Indicates whether documentation is included in the product's standard supply.

Local HMI Present

Indicates whether a local human-machine interface (HMI) is provided for monitoring, configuration, or control.

Display Present

Indicates whether the product has an integrated local display.

Display Type

Technology or construction type of the product's integrated display.

Display Backlight

Indicates whether the integrated display has a backlight.

Status LED Count

Number of integrated LEDs used to indicate product status or operating modes.

Event Log Supported

Indicates whether the product can store an internal event log.

Event Log Capacityevents

Maximum number of event records that can be stored in the product's internal log.

Real-Time Clock Present

Indicates whether an integrated real-time clock is provided for timekeeping, event time-stamping, or time-based functions.

Local Key Count

Number of integrated user keys or buttons available for local navigation, programming or control.

Compatible Coupling Device Family

Manufacturer family, series or designation of compatible external coupling devices or coupling impedances.

Level Sensor Supply Present

Indicates that the device provides an auxiliary supply output for external active level sensors.

Display of Measured Values Supported

Indicates that current measured values can be shown on the integrated display.

Display of Diagnostic Messages Supported

Indicates that fault, warning or diagnostic messages can be shown on the local display.

Display Status Color Indication Supported

Indicates that the display changes color or uses color coding to distinguish normal, warning, fault or configuration states.

Special Features123
Measured Value Memory Supported

Indicates whether one or more measured values can be stored, for example the latest, minimum, maximum, or a value associated with a fault event.

Fault Memory Supported

Indicates whether information about a fault condition, alarm, or protective operation can be retained after the cause of the event has disappeared.

Fault Memory Configurable

Indicates whether the mode of storing or latching a fault condition can be configured.

Automatic Reset Supported

Indicates whether an alarm or output state can automatically return to normal after the operating cause disappears, according to the product settings.

Adjustable Start-Up Delay

Indicates whether the delay can be adjusted during which a monitoring or protective function temporarily ignores the monitored condition after power-up or start.

Minimum Start-Up Delays

Minimum available setting of the start-up delay for the monitoring or protective function.

Maximum Start-Up Delays

Maximum available setting of the start-up delay for the monitoring or protective function.

Adjustable Release Delay

Indicates whether the delay before an alarm or output state returns after the operating condition disappears can be adjusted.

Minimum Release Delays

Minimum available setting of the release delay for the alarm or output state.

Maximum Release Delays

Maximum available setting of the release delay for the alarm or output state.

Adjustable Switching Hysteresis

Indicates whether the hysteresis between the operating threshold and release threshold can be adjusted.

Minimum Switching Hysteresis%

Minimum available setting of switching or alarm hysteresis relative to the corresponding threshold.

Maximum Switching Hysteresis%

Maximum available setting of switching or alarm hysteresis relative to the corresponding threshold.

External Test Input Supported

Indicates whether an external wired input or external push-button is supported for initiating the specified TEST function.

External Reset Input Supported

Indicates whether an external wired input or external push-button is supported for performing the specified RESET function.

Parameter Lock Supported

Indicates whether product settings can be protected against unauthorized modification by means of a specified mechanical, software, or password-based locking mechanism.

Phase Sequence Correction Supported

Indicates that the device can support automatic correction of phase sequence or direction of rotation through its switching outputs or associated switching arrangement.

Configurable Phase Sequence Correction

Indicates that automatic phase sequence correction behaviour can be enabled, disabled or otherwise configured.

Insulation Fault Location Supported

Indicates support for locating the faulty branch or circuit associated with an insulation fault, either internally or with compatible external equipment.

Insulation Fault Location Channel Count

Number of insulation fault location channels directly supported or evaluated by the device where applicable.

Sensor Open-Circuit Detection Supported

Indicates that an open sensor circuit or broken sensor lead can be detected.

Sensor Short-Circuit Detection Supported

Indicates that a short circuit in the sensor circuit can be detected.

Maximum Sensor Fault Detection Times

Maximum intrinsic time required to detect a supported sensor fault such as wire break or short circuit.

Temperature Difference Monitoring Supported

Indicates that the device can monitor the temperature difference between two measuring channels.

Individually Configurable Temperature Sensor Channels

Indicates that the sensor type and related parameters can be configured separately for individual temperature measuring channels.

Mixed Temperature Sensor Types Supported

Indicates that different temperature sensor technologies can be operated simultaneously on separate measuring channels.

Motor Winding Temperature Monitoring Supported

Indicates suitability for direct thermal monitoring of motor or generator windings using embedded temperature sensors.

Thermistor Warning Circuit Supported

Indicates support for a separate thermistor warning or pre-alarm sensor circuit in addition to the trip circuit.

Level Control Modes

Operating modes supported by the level monitoring function, such as filling, draining, minimum-level, maximum-level or two-point level control.

Conductive Liquid Monitoring Supported

Indicates that liquid level can be detected by measuring electrical conduction between immersed electrodes.

Liquid Conductivity Monitoring Supported

Indicates that the electrode measuring circuit can be used to monitor changes in liquid conductivity or mixture conductivity.

Independent Level Monitoring Channels

Indicates that multiple level monitoring channels can operate independently with separate sensing or output logic.

Conductive Tank as Reference Supported

Indicates that an electrically conductive tank wall may be used as the common reference electrode instead of a separate reference probe.

Single-Level Monitoring Supported

Indicates support for monitoring one defined level point using a sensing electrode and the applicable reference.

Two-Level Control Supported

Indicates support for control between separate minimum and maximum level electrodes.

Filling Control Supported

Indicates that relay logic is suitable for automatic filling control between defined liquid levels.

Draining Control Supported

Indicates that relay logic is suitable for automatic draining control between defined liquid levels.

Pump Control Supported

Indicates that the monitoring relay is intended to directly control a pump contactor or equivalent switching circuit according to liquid level.

Liquid Presence Detection Supported

Indicates that the device can be used for simple presence or absence detection of a conductive liquid.

Minimum Level Alarm Supported

Indicates support for a dedicated alarm or switching condition when the monitored liquid falls below the defined minimum level.

Maximum Level Alarm Supported

Indicates support for a dedicated alarm or switching condition when the monitored liquid reaches or exceeds the defined maximum level.

Level Probe Fault Monitoring Supported

Indicates that faults in the connected level probe circuit can be detected or diagnosed by the device.

Monitoring Delay Modes

Supported timing behaviours between detection of a monitored condition and operation or release of the monitoring output, such as ON-delay, OFF-delay or instantaneous operation.

Individually Configurable Monitoring Functions

Indicates that individual monitoring functions can be independently enabled, disabled or configured.

Configurable Relay Output Assignment

Indicates that monitoring, warning or fault functions can be assigned by configuration to individual relay outputs.

Fault Type Differentiation Supported

Indicates that the device distinguishes different monitored fault conditions for indication, output assignment, display or communication instead of providing only one undifferentiated fault state.

Source Monitoring Functions

Electrical parameters and source conditions that the device can monitor when making transfer decisions.

Programmable Digital Inputs Supported

Indicates whether user-configurable functions can be assigned to one or more digital inputs.

Programmable Digital Outputs Supported

Indicates whether user-configurable functions can be assigned to one or more digital outputs.

Communication Supported

Indicates whether the product supports digital data exchange with external devices or systems.

Communication Protocols

List of supported digital data communication protocols.

Communication Interfaces

List of supported physical or logical digital communication interfaces.

Integrated Web Server

Indicates whether an integrated web server or web interface is provided for access to product functions.

Remote Configuration Supported

Indicates whether specified product settings can be read or changed remotely through a supported communication interface.

Data Logger Supported

Indicates whether a data-logging function is provided for recording supported measurements, states, or process parameters.

Configurable Data Logger Trigger

Indicates whether the user can configure the condition that triggers or starts data logging.

Test Button Present

Indicates whether the product has a local TEST button for the specified functional check of the device.

Reset Button Present

Indicates whether the product has a separate local RESET button for performing the specified reset function.

Status Indicator Present

Indicates whether the product has a local visual or mechanical indicator of operating, fault, or end-of-life status.

Status Indicator Types

Types of local visual or mechanical status indication provided by the product design.

Firmware Updatable

Indicates that device firmware can be updated by a manufacturer-supported procedure.

Monitoring Function Configurable

Indicates that the principal monitoring function can be selected or configured on the product, for example over-value, under-value or window monitoring.

Monitoring Threshold Setting Method

Methods available for setting monitoring or switching threshold values.

Adjustable Monitoring Trip Delay

Indicates that the delay between detection of the monitored fault condition and switching of the monitoring output can be adjusted.

Minimum Monitoring Trip Delays

Minimum configurable delay between detection of a monitored fault condition and output switching.

Maximum Monitoring Trip Delays

Maximum configurable delay between detection of a monitored fault condition and output switching.

Monitoring Trip Delay Mode

Timing behaviour of the monitoring relay output with respect to appearance or disappearance of the monitored condition.

Monitoring Output Principle Configurable

Indicates that the monitoring output can be configured between supported operating principles.

Voltage Monitoring Functions

Voltage supervision functions supported by the product, such as overvoltage, undervoltage or window monitoring.

Phase-to-Phase Voltage Monitoring Supported

Indicates that the product evaluates or indicates phase-to-phase voltages of the monitored multiphase system.

Phase-to-Neutral Voltage Monitoring Supported

Indicates that the product evaluates or indicates phase-to-neutral voltages of the monitored electrical system.

Interrupted Neutral Monitoring Supported

Indicates that interruption or loss of the neutral conductor can be detected or indicated by the product.

Neutral Monitoring Configurable

Indicates that neutral-conductor monitoring can be enabled, disabled or otherwise configured by the user.

Phase Sequence Monitoring Configurable

Indicates that phase-sequence monitoring can be enabled, disabled or configured by the user.

Automatic Phase Sequence Correction Supported

Indicates support for an output/control arrangement intended to automatically correct an incorrect phase sequence using external switching equipment.

Phase Failure Threshold Adjustable

Indicates that the voltage criterion used to identify phase failure can be adjusted.

Phase Failure Detection with Regenerative Voltage Supported

Indicates that the monitoring method is designed to detect a missing phase even when regenerative or back-fed voltage from the connected load is present.

Phase Asymmetry Threshold Adjustable

Indicates that the permitted phase-voltage asymmetry or voltage-unbalance threshold can be adjusted.

ROCOF Monitoring Supported

Indicates support for monitoring the rate of change of frequency (ROCOF, df/dt).

Automatic Current Type Detection

Indicates that the measuring input automatically distinguishes between AC and DC current without manual selection.

Current Monitoring Functions

Current supervision functions supported by the device.

External Shunt Measurement Supported

Indicates that current can be monitored using an external measuring shunt.

Power Monitoring Functions

Supported under-limit, over-limit, window and reverse-power monitoring functions for active, reactive or apparent power.

Power Flow Direction Detection Supported

Indicates that the device can distinguish the direction of active power flow.

Power Factor Monitoring Functions

Power-factor supervision functions supported by the device.

Inductive / Capacitive Power Factor Discrimination Supported

Indicates that the device distinguishes inductive lagging and capacitive leading power-factor conditions.

Active Current Monitoring Functions

Under-limit, over-limit and window monitoring functions for the active current component Ires.

Insulation Monitoring Functions

Insulation-system monitoring and diagnostic functions supported by the product.

Automatic Leakage Capacitance Adaptation Supported

Indicates that the measuring algorithm automatically adapts to the existing system leakage capacitance.

Automatic Self-Test Supported

Indicates that the product can automatically test its internal monitoring or measuring functionality.

Manual Self-Test Supported

Indicates that an internal functional self-test can be initiated manually.

Measuring Line Connection Monitoring Supported

Indicates monitoring of the electrical connection between the device measuring terminals and the monitored system.

Earth Connection Monitoring Supported

Indicates monitoring of the device connection to protective earth or the reference earth connection required by the measuring circuit.

External Coupling Device Supported

Indicates that an external coupling device or coupling impedance can be used to extend the supported monitored-system voltage range or application range.

External Coupling Device Required

Indicates that an external coupling device or coupling impedance is required for the declared application or monitored-system voltage range.

Locating Current Injection Supported

Indicates that the device can inject a locating current for use by a compatible insulation fault location system.

Temperature Measurement Supported

Indicates that the device measures and evaluates an actual temperature value rather than only a thermistor resistance state.

Temperature Monitoring Functions

Temperature supervision functions supported by the product.

Temperature Sensor Open-Circuit Detection Supported

Indicates detection of an open sensor circuit or interrupted sensor wire.

Temperature Sensor Short-Circuit Detection Supported

Indicates detection of a short circuit in the temperature sensor measuring circuit.

Dynamic Sensor Wire-Break Detection Supported

Indicates that wire-break detection is performed dynamically during normal monitoring operation.

PTC Type A Sensor Supported

Indicates compatibility with PTC thermistor sensors of the Type A characteristic used for built-in thermal protection of rotating electrical machines.

PTC Short-Circuit Detection Configurable

Indicates that short-circuit monitoring of the PTC sensor circuit can be enabled, disabled or otherwise configured.

Level Monitoring Functions

Level monitoring, pump protection and conductivity-related functions supported by the product.

Common Reference Electrode Required

Indicates that a dedicated common or reference electrode is required for normal conductive level sensing.

Conductive Medium Required

Indicates that direct probe-based level detection requires an electrically conductive liquid or medium.

Simultaneous Monitoring Supported

Indicates that multiple measured quantities or monitoring functions can be evaluated simultaneously.

Differentiated Fault Messages Supported

Indicates that the device identifies or reports different monitored fault causes separately rather than providing only one collective fault indication.

Digital Input Assignment Configurable

Indicates that digital input functions such as reset, inhibit, parameter-set selection or other control commands can be configured.

Parameter Set Switching Supported

Indicates that the active parameter or setting set can be changed during operation by a supported control method.

Parameter Set Selection Methods

Methods supported for selection or switching of the active parameter set.

Parameter Set Copy Supported

Indicates that one parameter set can be copied to another internal parameter set or configuration slot.

Parameter Backup Supported

Indicates that device parameters and configuration data can be backed up to an external system or supported storage medium.

Parameter Restore Supported

Indicates that previously stored device parameters or configuration data can be restored to the product.

Automatic Parameter Restore on Device Replacement Supported

Indicates that backed-up parameters can be transferred automatically or semi-automatically to a replacement device through a supported communication system.

Local Configuration Supported

Indicates that device settings can be configured directly on the product using integrated controls or a local HMI.

Measured Value Memory Types

Types of measured values that can be retained by the product, such as last, minimum, maximum or fault-associated values.

Event Timestamp Supported

Indicates that stored events, warnings or faults can include a date and/or time stamp.

Trend Data Supported

Indicates that measured-value trends or historical sequences can be stored, transmitted or evaluated.

Remote Measured Value Readout Supported

Indicates that current measured values can be read by an external controller, software system or communication master.

Remote Reset Supported

Indicates whether a latched trip, fault, or alarm state can be reset remotely through a supported command or interface.

Remote Test Supported

Indicates that an internal test or test function can be initiated remotely through a supported interface.

Diagnostics via Communication Supported

Indicates that warning, fault, status or diagnostic information can be transmitted through a supported digital communication interface.

Standards and Compliance29
Conformity Regions

Regions or markets for which the manufacturer declares regulatory or certification compliance of the product.

Certification and Conformity Marks

Certification, market-approval, or conformity marks applicable to the product.

Primary Product Standard

Primary normative document or standard according to which the manufacturer classifies or assesses the product.

Additional Standards

Additional normative documents and standards declared by the manufacturer as applicable to the product.

Declaration of Conformity Available

Indicates whether an official declaration of conformity is available for the product.

Certificate Available

Indicates whether a certificate relating to the declared certification or conformity of the product is available.

Certificate Number

Identification number of the certificate relating to the product or its certified version.

Certification Body

Name of the organization that issued the certificate or performed the relevant conformity assessment.

Third-Party Tested

Indicates whether the product was tested by an organization independent of the manufacturer.

CE Marked

Indicates whether the CE marking is applied to the product where applicable.

UKCA Marked

Indicates whether the UKCA marking is applied to the product where applicable.

EAC Marked

Indicates whether the EAC marking is applied to the product where applicable.

UL Listed

Indicates whether the product has a declared UL Listed certification or recognition status.

UL Recognized

Indicates whether the product has a declared UL Recognized certification or recognition status.

cULus Marked

Indicates whether the cULus mark is applied to the product where applicable.

CSA Certified

Indicates whether the product has a declared CSA certification or recognition status.

TÜV Certified

Indicates whether the product has a declared TÜV certification or recognition status.

VDE Certified

Indicates whether the product has a declared VDE certification or recognition status.

ATEX Conformity

Indicates declared conformity of the product with applicable ATEX requirements for equipment intended for potentially explosive atmospheres.

RoHS Compliant

Indicates whether product compliance with applicable RoHS restrictions on hazardous substances has been declared.

REACH Compliant

Indicates whether the manufacturer declares compliance of the product with applicable REACH Regulation requirements.

WEEE Applicable

Indicates whether the product falls within the scope of WEEE requirements for waste electrical and electronic equipment.

IEC 60947-5-1 Compliant

Compliance with applicable IEC 60947-5-1 requirements for control-circuit devices and switching elements.

IEC 61557-8 Compliant

Compliance with applicable IEC 61557-8 requirements for insulation monitoring devices in IT systems.

IEC 61557-9 Compliant

Compliance with applicable IEC 61557-9 requirements for insulation fault location systems in IT systems.

IEC 60947-8 Compliant

Compliance with applicable IEC 60947-8 requirements for control units used with built-in PTC thermal protection of rotating electrical machines.

IEC 60255-1 Compliant

Compliance with applicable IEC 60255-1 common requirements for measuring relays and protection equipment.

IEC 60255-26 Compliant

Compliance with applicable IEC 60255-26 electromagnetic compatibility requirements for measuring relays and protection equipment.

IEC 60255-27 Compliant

Compliance with applicable IEC 60255-27 product safety requirements for measuring relays and protection equipment.

Logistics10
Net Weightkg

Mass of the product itself, excluding transport packaging, additional accessories, and external equipment.

Gross Weightkg

Mass of the product together with its individual packaging and the accessories included in it.

Package Widthmm

External horizontal dimension of the product's individual package.

Package Heightmm

External vertical dimension of the product's individual package.

Package Depthmm

External depth dimension of the product's individual package.

Packaging Type

Design type of the product's individual or transport packaging.

Units per Package

Number of individual products contained in one packaging unit at the specified level.

Country of Origin

Country of origin of the goods declared for customs or commercial purposes.

HS Code

Commodity code under the international Harmonized Commodity Description and Coding System.

Combined Nomenclature Code

Commodity code under the Combined Nomenclature of the European Union.