TRASA3 Knowledge Base

Electrical Component Parameter Reference

An open technical reference for electrical component types, their applications, and selection parameters.

This material is also available in PL and RU.

Device description

Frequency Meter

Measuring instrument for determining and displaying the frequency of an electrical signal or network.

A frequency meter is intended to measure the frequency of voltage or another applicable electrical signal.

Principal characteristics include minimum and maximum frequency range, accuracy, resolution, and required input-signal parameters.

Depending on the design, the instrument may be digital or analogue, panel-mounted, modular, or integrated with another measuring device.

For network applications, compatibility of the measuring range with the nominal system frequency and suitable measuring-input withstand are particularly important.

Selection criteria include frequency range, accuracy, input voltage, display type, dimensions, and mounting method.

Components in this subcategory

Panel-mounted digital and analogue frequency meters and frequency indicators for electrical networks and generators.

Available parameters

Frequency Meter

193 parameters
General6
Product Series

Commercial or technical designation of a manufacturer's product family sharing a common design and compatible characteristics.

Application

Range of tasks and systems for which the manufacturer recommends the component.

Intended Use

Primary function of the device and its intended use as defined by its design and the manufacturer's documentation.

Installation Location

Permissible installation location of the product: indoors, outdoors, in a technical area, or as part of equipment.

Installation Environment

Environmental conditions under which installation and operation of the product are permitted.

Orientation

Permissible spatial orientation of the component during installation and operation.

Dimensions12
Widthmm

External horizontal dimension of the product between its outermost lateral points.

Heightmm

External vertical dimension of the product from its lowest to its highest point.

Depthmm

External distance between the foremost and rearmost surfaces of the product.

Installation Cutout Widthmm

Horizontal dimension of the mounting cutout or opening required to install the product in a prepared surface or recess.

Installation Cutout Heightmm

Vertical dimension of the mounting cutout or opening required to install the product in a prepared surface or recess.

Installation Cutout Depthmm

Depth of the mounting cutout or recess intended to accommodate the recessed part of the product.

Flush Mounting Depthmm

Depth of the enclosure portion installed within a wall or mounting recess.

Front Projection Depthmm

Distance by which the front part of the installed product projects beyond the wall surface.

Terminal Pitchmm

Centre-to-centre pitch between adjacent electrical terminals in the relevant terminal row.

Front Bezel Widthmm

External width of the front bezel or front frame of a panel-mounted measuring device.

Front Bezel Heightmm

External height of the front bezel or front frame of a panel-mounted measuring device.

Front Bezel Shape

Geometric shape of the visible front bezel of a panel-mounted measuring instrument.

Capacity and Layout10
Digital Input Count

Number of available digital inputs of the product.

Digital Output Count

Number of available digital outputs of the product.

Terminal Block Count

Number of terminal blocks included in the product's standard equipment or provided for the specific version.

Relay Output Count

Number of independent relay outputs or sets of switching contacts provided by the product.

Analog Output Count

Number of integrated analog outputs provided by the product.

Ethernet Port Count

Number of integrated physical Ethernet communication ports.

RS-485 Port Count

Number of integrated physical RS-485 communication interfaces.

USB Port Count

Number of integrated physical USB ports provided by the product, including charging, data, communication or programming ports.

Monitoring Threshold Count

Number of independently usable monitoring, switching or alarm thresholds provided by the device.

Panel Mounting Clamp Count

Number of supplied or required panel mounting clamps used to retain the device in the installation cutout.

Materials and Finish4
Material

Primary material from which the product is manufactured.

Material Grade

Grade, alloy, class, or technical designation of the product's primary material.

Color

Primary visually perceived colour of the product's external surface.

RAL Color

Designation of the product's primary surface colour according to the RAL colour system.

Mounting and Installation12
Mounting Type

Installation arrangement permitted by the product design, such as wall-mounted, flush-mounted, floor-mounted, or another specified mounting type.

Mounting Method

Method used to mechanically secure the product to a support, surface, or load-bearing structure.

Conductor Connection Type

Conductor connection methods supported by the specified terminals or connection elements.

Terminal Tightening TorqueNm

Tightening torque specified by the manufacturer for a screw or bolted terminal connection.

Removable Terminal Blocks

Indicates that one or more terminal blocks can be removed from the device body for wiring or service.

Pluggable Terminal Blocks

Indicates that one or more electrical terminal blocks use a pluggable disconnectable connection system.

Terminal Marking Present

Indicates that electrical connection terminals are individually identified by manufacturer-applied markings.

Terminal Access Direction

Physical directions from which conductors or tools access the electrical connection terminals.

Minimum Terminal Conductor Cross-Sectionmm²

Minimum conductor cross-section accepted by the relevant general device terminal connection.

Maximum Terminal Conductor Cross-Sectionmm²

Maximum conductor cross-section accepted by the relevant general device terminal connection.

Terminal Screw Thread

Thread designation of the screw used in the conductor clamping mechanism, for example M2.5, M3, M4, or another manufacturer-declared designation.

Panel Mounting Clamp Included

Indicates that the clamping element required to secure a panel-mounted device in its cutout is supplied with the product.

Electrical Parameters24
Supply Current Type

Type of electrical current for which the product's main supply circuit is intended.

Rated VoltageV

Voltage value assigned to the product by the manufacturer for specified application conditions and characteristics.

Rated FrequencyHz

AC frequency assigned to the product for normal operating conditions.

Minimum FrequencyHz

Lower limit of the electrical network or signal frequency at which product operation is permitted.

Maximum FrequencyHz

Upper limit of the electrical network or signal frequency at which product operation is permitted.

Number of Phases

Number of phases of the electrical system for which the product is designed to be connected or used.

Auxiliary Supply VoltageV

Rated external auxiliary supply voltage required for the product's active functions.

Auxiliary Supply Type

Type of current and source used for the product's auxiliary supply.

Rated Insulation VoltageV

Voltage with reference to which the product's insulation clearances and dielectric properties are specified.

Rated Impulse Withstand VoltagekV

Peak value of an impulse voltage of specified waveform that the product insulation must withstand without breakdown.

Dielectric Test VoltageV

Test voltage applied to verify the dielectric strength of the product insulation.

Minimum Insulation ResistanceMΩ

Minimum permissible insulation resistance between the specified electrically separated parts.

Overvoltage Category

Category characterizing the expected level of impulse overvoltages at the product's point of use.

Pollution Degree

Degree of pollution of the surrounding microenvironment considered when selecting insulation distances and product characteristics.

Insulation Type

Type of electrical insulation used, considered in terms of its protective function and construction.

Frequency Measurement Supported

Indicates whether the product can measure and provide electrical network frequency values.

Analog Output Types

Types of analog signals supported by the product outputs.

Measurement Principle

Electrical measurement principle used for evaluation of the monitored signal, such as true RMS, RMS, average-value or direct-value measurement.

Self-Powered from Measured Circuit

Indicates that the monitoring device derives its operating power directly from the measured circuit and does not require a separate auxiliary supply.

Minimum Measurement FrequencyHz

Minimum signal frequency accepted by the measuring circuit for the declared monitoring or measurement function.

Maximum Measurement FrequencyHz

Maximum signal frequency accepted by the measuring circuit for the declared monitoring or measurement function.

Frequency Measurement AccuracyHz

Manufacturer-declared absolute accuracy of frequency measurement.

Measurement Sampling Ratesamples/s

Sampling rate used by the measuring system for acquisition of electrical signals.

Measurement Update Intervalms

Time interval between successive updates of measured or calculated values made available by the device.

Protection and Safety8
IP Rating

Degree of enclosure protection against access to hazardous parts and ingress of solid objects and water, designated by the IP code.

IK Rating

Class of enclosure resistance to external mechanical impacts designated by the IK code.

Protection Against Direct Contact

Method or level of protection of the user against direct contact with hazardous live parts.

Finger-Safe

Indicates whether the design prevents finger access to hazardous live parts in the intended condition.

Flammability Class

Classification of a material according to its ability to ignite, sustain combustion, and cease burning under a specified test.

Glow-Wire Test Temperature°C

Temperature of the heated wire used when testing the material or product against an ignition source.

Halogen-Free

Indicates whether the product material is classified as halogen-free according to the characteristics declared by the manufacturer.

Sealable Terminal Cover

Indicates that the terminal cover can be sealed or plombed against unauthorized access.

Environmental Conditions14
Minimum Operating Temperature°C

Minimum ambient temperature at which normal operation of the product is permitted.

Maximum Operating Temperature°C

Maximum ambient temperature at which normal operation of the product is permitted.

Maximum 24-Hour Average Temperature°C

Maximum permissible average ambient temperature over a consecutive 24-hour period.

Minimum Storage Temperature°C

Minimum ambient temperature permitted during storage of the product while not in operation.

Maximum Storage Temperature°C

Maximum ambient temperature permitted during storage of the product while not in operation.

Minimum Relative Humidity%

Minimum relative air humidity permitted for the declared operating or test condition.

Maximum Relative Humidity%

Maximum relative air humidity permitted for the declared operating or test condition.

Relative Humidity Reference Temperature°C

Temperature at which the corresponding relative humidity value is specified or standardized.

Non-Condensing Humidity

Indicates whether the permissible humidity value applies only to non-condensing conditions.

Maximum Installation Altitudem

Maximum altitude above sea level at which the product may be installed without exceeding the declared conditions.

Altitude Derating Required

Indicates whether the permissible product load must be reduced as installation altitude increases.

Altitude Derating Startm

Altitude above sea level above which the permissible product load must be reduced.

Vibration Resistant

Indicates whether the product's resistance to vibration has been verified under the declared conditions.

Mechanical Shock Resistant

Indicates whether the product's resistance to short-duration mechanical shocks has been verified.

Included Equipment22
Touchscreen Present

Indicates whether a touchscreen is provided for user input through the local HMI.

Local HMI Present

Indicates whether a local human-machine interface (HMI) is provided for monitoring, configuration, or control.

Display Present

Indicates whether the product has an integrated local display.

Display Type

Technology or construction type of the product's integrated display.

Display Backlight

Indicates whether the integrated display has a backlight.

Status LED Count

Number of integrated LEDs used to indicate product status or operating modes.

Documentation Included

Indicates whether documentation is included in the product's standard supply.

Installation Manual Included

Indicates whether an installation manual is included with the product.

Local Key Count

Number of integrated user keys or buttons available for local navigation, programming or control.

Display of Measured Values Supported

Indicates that current measured values can be shown on the integrated display.

Display of Diagnostic Messages Supported

Indicates that fault, warning or diagnostic messages can be shown on the local display.

Display Status Color Indication Supported

Indicates that the display changes color or uses color coding to distinguish normal, warning, fault or configuration states.

Display Digit Count

Number of numeric digits that can be shown simultaneously on the primary numeric display field.

Display Line Count

Number of simultaneously visible text or measurement lines on the integrated display.

Display Characters per Line

Maximum number of alphanumeric characters displayed in one text line.

Horizontal Display Resolutionpx

Horizontal pixel resolution of a graphical integrated display.

Vertical Display Resolutionpx

Vertical pixel resolution of a graphical integrated display.

Display Diagonalmm

Physical diagonal dimension of the integrated display viewing area.

Display Page Count

Number of predefined or configurable local display pages available for measured values or device information.

Display Auto-Scroll Supported

Indicates that the device can automatically cycle through display pages or measured values.

Display Hold Function Supported

Indicates that the currently displayed measured value can be held or frozen on the local display.

Display Unit Indication Supported

Indicates that the measurement unit associated with a displayed value is shown locally.

Special Features47
Minimum / Maximum Measurement Supported

Indicates whether the product stores or provides minimum and maximum values of measured quantities.

Event Log Supported

Indicates whether the product can store an internal event log.

Self-Diagnostics Supported

Indicates whether the product performs internal diagnostic checks to detect or report internal faults.

Event Log Capacityevents

Maximum number of event records that can be stored in the product's internal log.

Real-Time Clock Present

Indicates whether an integrated real-time clock is provided for timekeeping, event time-stamping, or time-based functions.

Programmable Digital Inputs Supported

Indicates whether user-configurable functions can be assigned to one or more digital inputs.

Programmable Digital Outputs Supported

Indicates whether user-configurable functions can be assigned to one or more digital outputs.

Communication Supported

Indicates whether the product supports digital data exchange with external devices or systems.

Communication Protocols

List of supported digital data communication protocols.

Communication Interfaces

List of supported physical or logical digital communication interfaces.

Remote Configuration Supported

Indicates whether specified product settings can be read or changed remotely through a supported communication interface.

Remote Diagnostics Supported

Indicates whether diagnostic information, status data, or fault information can be obtained remotely.

Measured Value Memory Supported

Indicates whether one or more measured values can be stored, for example the latest, minimum, maximum, or a value associated with a fault event.

Relay Output Functions

Functions permanently assigned or assignable to the product relay outputs.

Firmware Updatable

Indicates that device firmware can be updated by a manufacturer-supported procedure.

RTC Backup Timeh

Manufacturer-declared duration for which the real-time clock continues to retain valid time information without normal supply voltage.

Monitoring Functions

Electrical or physical monitoring functions provided by the device, such as overvalue, undervalue, window, phase, frequency, current, power, insulation, temperature or level monitoring.

Local Configuration Supported

Indicates that device settings can be configured directly on the product using integrated controls or a local HMI.

Measured Value Memory Types

Types of measured values that can be retained by the product, such as last, minimum, maximum or fault-associated values.

Event Timestamp Supported

Indicates that stored events, warnings or faults can include a date and/or time stamp.

Remote Measured Value Readout Supported

Indicates that current measured values can be read by an external controller, software system or communication master.

Diagnostics via Communication Supported

Indicates that warning, fault, status or diagnostic information can be transmitted through a supported digital communication interface.

Local Configuration Lock Supported

Indicates that local configuration access can be intentionally restricted against unauthorized changes.

Local Configuration Lock Methods

Methods supported for restricting access to local device configuration.

Measurement Data Logging Supported

Indicates that measured electrical values can be stored internally as historical measurement records.

Measurement Data Log Capacityrecords

Maximum number of historical measurement records retained internally.

Configurable Measurement Logging Interval

Indicates that the interval between periodic measurement records can be configured.

Minimum Measurement Logging Intervals

Minimum configurable interval between periodically stored measurement records.

Maximum Measurement Logging Intervals

Maximum configurable interval between periodically stored measurement records.

Historical Data Export Supported

Indicates that stored measurement or event history can be exported from the device.

Measurement Data Export Formats

File or interchange formats supported for exporting stored measurement data.

Supported Serial Baud Rates

Supported serial communication baud rates for interfaces such as RS-232, RS-422, RS-485 or equivalent serial buses.

Supported Serial Data Bits

Supported data-word lengths for serial communication.

Supported Serial Parity Modes

Parity modes supported by the serial communication interface.

Supported Serial Stop Bits

Supported number of stop bits in serial communication frames.

Digital Input Functions

Functions that can be assigned or are dedicated to integrated digital inputs.

Digital Output Functions

Functions that can be assigned or are dedicated to integrated digital outputs.

Configurable Analog Output Scaling

Indicates that the correspondence between measured quantity and analogue output signal range can be configured.

Analog Output Assigned Quantities

Measured quantities that can be assigned to an analogue output channel.

Min/Max Timestamp Supported

Indicates that stored minimum and maximum measured values include the time at which the extreme value occurred.

Measurement Alarm Supported

Indicates that measured or calculated quantities can be compared with configured limits to generate alarms or status conditions.

Alarm Output Assignment Supported

Indicates that configured measurement alarms can be assigned to available relay, digital or equivalent outputs.

Input Wiring Error Detection Supported

Indicates that the measuring device can detect manufacturer-defined wiring errors affecting its voltage or current measurement inputs.

Measurement Overrange Indication Supported

Indicates explicit indication when an input or calculated measured quantity exceeds its valid measurement range.

Measurement Underrange Indication Supported

Indicates explicit indication when an input or measured quantity is below its valid or usable measurement range.

RTC Backup Status Monitoring Supported

Indicates that the condition of the battery, capacitor or other backup source used for the real-time clock can be monitored or diagnosed.

Memory Integrity Monitoring Supported

Indicates that the device can detect corruption or integrity failures affecting stored configuration, measurement or metrological data.

Standards and Compliance25
Conformity Regions

Regions or markets for which the manufacturer declares regulatory or certification compliance of the product.

Certification and Conformity Marks

Certification, market-approval, or conformity marks applicable to the product.

Primary Product Standard

Primary normative document or standard according to which the manufacturer classifies or assesses the product.

Additional Standards

Additional normative documents and standards declared by the manufacturer as applicable to the product.

Declaration of Conformity Available

Indicates whether an official declaration of conformity is available for the product.

Certificate Available

Indicates whether a certificate relating to the declared certification or conformity of the product is available.

Certificate Number

Identification number of the certificate relating to the product or its certified version.

Certification Body

Name of the organization that issued the certificate or performed the relevant conformity assessment.

CE Marked

Indicates whether the CE marking is applied to the product where applicable.

EAC Marked

Indicates whether the EAC marking is applied to the product where applicable.

cULus Marked

Indicates whether the cULus mark is applied to the product where applicable.

CSA Certified

Indicates whether the product has a declared CSA certification or recognition status.

RoHS Compliant

Indicates whether product compliance with applicable RoHS restrictions on hazardous substances has been declared.

REACH Compliant

Indicates whether the manufacturer declares compliance of the product with applicable REACH Regulation requirements.

Calibration Supported

Indicates that the measuring function can be calibrated using a manufacturer-defined procedure.

Factory Calibrated

Indicates that the product is calibrated by the manufacturer before delivery.

Calibration Certificate Available

Indicates that a calibration certificate can be supplied for the product.

Recommended Calibration Intervalmonths

Manufacturer-recommended interval between periodic calibrations, where such an interval is specified.

Field Calibration Supported

Indicates that calibration can be performed in the installed location without factory return.

User Calibration Supported

Indicates that an authorized user can execute a manufacturer-supported calibration procedure.

Zero Calibration Supported

Indicates support for adjustment or calibration of measurement zero offset.

Span Calibration Supported

Indicates support for gain or span calibration using a reference measurement value.

Calibration Point Count

Number of calibration points supported by the manufacturer-defined calibration procedure.

Calibration Access Protected

Indicates that access to calibration parameters or procedures is protected against unauthorized changes.

Measurement Accuracy Verification Supported

Indicates that the manufacturer provides a defined procedure or test facility for verifying measurement accuracy.

Logistics9
Gross Weightkg

Mass of the product together with its individual packaging and the accessories included in it.

Package Widthmm

External horizontal dimension of the product's individual package.

Package Heightmm

External vertical dimension of the product's individual package.

Package Depthmm

External depth dimension of the product's individual package.

Packaging Type

Design type of the product's individual or transport packaging.

Net Weightkg

Mass of the product itself, excluding transport packaging, additional accessories, and external equipment.

Country of Origin

Country of origin of the goods declared for customs or commercial purposes.

HS Code

Commodity code under the international Harmonized Commodity Description and Coding System.

Combined Nomenclature Code

Commodity code under the Combined Nomenclature of the European Union.