Device description

Bidirectional Energy Meter

Meter intended to measure energy separately in import and export directions.

A bidirectional electricity meter measures and registers electrical-energy flow in both directions.

The instrument can separately account for energy imported from the grid and energy exported back to the grid. This function is used in distributed-generation systems, photovoltaic installations, energy-storage systems, and other applications with bidirectional energy exchange.

Depending on the model, active and reactive energy, four-quadrant metering, separate tariff registers, reverse-flow detection, load profiling, and remote data transmission may be supported.

For billing applications, accuracy class, metrological certification, register protection, and compliance with revenue-metering requirements are important.

Selection criteria include supported energy directions, register types, measuring connection arrangement, current ranges, tariffs, and communication interfaces.

Components in this subcategory

Bidirectional import/export meters, four-quadrant meters, and metering instruments for distributed-generation and energy-storage systems.

Available parameters

Bidirectional Energy Meter

380 parameters
General6
Product Series

Commercial or technical designation of a manufacturer's product family sharing a common design and compatible characteristics.

Application

Range of tasks and systems for which the manufacturer recommends the component.

Intended Use

Primary function of the device and its intended use as defined by its design and the manufacturer's documentation.

Installation Location

Permissible installation location of the product: indoors, outdoors, in a technical area, or as part of equipment.

Installation Environment

Environmental conditions under which installation and operation of the product are permitted.

Orientation

Permissible spatial orientation of the component during installation and operation.

Dimensions3
Widthmm

External horizontal dimension of the product between its outermost lateral points.

Heightmm

External vertical dimension of the product from its lowest to its highest point.

Depthmm

External distance between the foremost and rearmost surfaces of the product.

Capacity and Layout10
Digital Input Count

Number of available digital inputs of the product.

Digital Output Count

Number of available digital outputs of the product.

Relay Output Count

Number of independent relay outputs or sets of switching contacts provided by the product.

Pulse Output Count

Number of outputs capable of generating manufacturer-declared high-speed pulse signals.

Ethernet Port Count

Number of integrated physical Ethernet communication ports.

RS-485 Port Count

Number of integrated physical RS-485 communication interfaces.

USB Port Count

Number of integrated physical USB ports provided by the product, including charging, data, communication or programming ports.

Monitoring Threshold Count

Number of independently usable monitoring, switching or alarm thresholds provided by the device.

Pulse Input Count

Number of dedicated inputs capable of receiving pulse signals for counting, metering or accumulation.

Pulse Input Counter Capacity

Maximum pulse count that can be accumulated by the corresponding internal counter before rollover or reset.

Materials and Finish4
Material

Primary material from which the product is manufactured.

Material Grade

Grade, alloy, class, or technical designation of the product's primary material.

Color

Primary visually perceived colour of the product's external surface.

RAL Color

Designation of the product's primary surface colour according to the RAL colour system.

Mounting and Installation2
Mounting Type

Installation arrangement permitted by the product design, such as wall-mounted, flush-mounted, floor-mounted, or another specified mounting type.

Mounting Method

Method used to mechanically secure the product to a support, surface, or load-bearing structure.

Electrical Parameters109
Supply Current Type

Type of electrical current for which the product's main supply circuit is intended.

Rated VoltageV

Voltage value assigned to the product by the manufacturer for specified application conditions and characteristics.

Rated FrequencyHz

AC frequency assigned to the product for normal operating conditions.

Minimum FrequencyHz

Lower limit of the electrical network or signal frequency at which product operation is permitted.

Maximum FrequencyHz

Upper limit of the electrical network or signal frequency at which product operation is permitted.

Number of Phases

Number of phases of the electrical system for which the product is designed to be connected or used.

Auxiliary Supply VoltageV

Rated external auxiliary supply voltage required for the product's active functions.

Auxiliary Supply Type

Type of current and source used for the product's auxiliary supply.

Rated Insulation VoltageV

Voltage with reference to which the product's insulation clearances and dielectric properties are specified.

Rated Impulse Withstand VoltagekV

Peak value of an impulse voltage of specified waveform that the product insulation must withstand without breakdown.

Dielectric Test VoltageV

Test voltage applied to verify the dielectric strength of the product insulation.

Minimum Insulation ResistanceMΩ

Minimum permissible insulation resistance between the specified electrically separated parts.

Overvoltage Category

Category characterizing the expected level of impulse overvoltages at the product's point of use.

Pollution Degree

Degree of pollution of the surrounding microenvironment considered when selecting insulation distances and product characteristics.

Insulation Type

Type of electrical insulation used, considered in terms of its protective function and construction.

Voltage Measurement Supported

Indicates whether the product can measure and provide electrical voltage values.

Current Measurement Supported

Indicates whether the product can measure and provide electrical current values.

Frequency Measurement Supported

Indicates whether the product can measure and provide electrical network frequency values.

Power Measurement Supported

Indicates whether measurement of active, reactive, or apparent electrical power is supported.

Energy Measurement Supported

Indicates whether measurement or cumulative metering of electrical energy is supported.

Measurement Principle

Electrical measurement principle used for evaluation of the monitored signal, such as true RMS, RMS, average-value or direct-value measurement.

Self-Powered from Measured Circuit

Indicates that the monitoring device derives its operating power directly from the measured circuit and does not require a separate auxiliary supply.

Minimum Measurement FrequencyHz

Minimum signal frequency accepted by the measuring circuit for the declared monitoring or measurement function.

Maximum Measurement FrequencyHz

Maximum signal frequency accepted by the measuring circuit for the declared monitoring or measurement function.

Voltage Measurement Accuracy%

Manufacturer-declared accuracy of voltage measurement where expressed as a single percentage value.

Minimum Voltage Measurement RangeV

Lowest voltage that can be measured or monitored within the manufacturer-declared measuring range.

Maximum Voltage Measurement RangeV

Highest voltage that can be measured or monitored within the manufacturer-declared measuring range.

Voltage Measurement Reference

Electrical voltage relationships measured by the device, for example line-to-line or line-to-neutral.

Frequency Measurement AccuracyHz

Manufacturer-declared absolute accuracy of frequency measurement.

Minimum Current Measurement RangeA

Lowest current that can be measured or monitored within the manufacturer-declared measuring range.

Maximum Current Measurement RangeA

Highest current that can be measured or monitored within the manufacturer-declared measuring range.

Current Transformer Input Supported

Indicates that the measuring circuit supports connection through an external current transformer.

Configurable Current Transformer Ratio

Indicates that the current transformer ratio used for measurement scaling can be configured in the device.

Minimum Current Transformer Primary Current SettingA

Minimum configurable primary current value used for current transformer scaling.

Maximum Current Transformer Primary Current SettingA

Maximum configurable primary current value used for current transformer scaling.

Supported Current Transformer Secondary Currents

Standard secondary current ratings of external current transformers supported by the measuring input.

Active Power Measurement Supported

Indicates that active electrical power is measured or calculated by the device.

Current Measurement Accuracy%

Manufacturer-declared relative accuracy of current measurement where expressed as a percentage.

Reactive Power Measurement Supported

Indicates that reactive electrical power is measured or calculated by the device.

Apparent Power Measurement Supported

Indicates that apparent electrical power is measured or calculated by the device.

Power Factor Measurement Supported

Indicates that the electrical power factor is measured or calculated by the device.

Current Measurement Connection Method

Supported methods for connecting the monitored current to the measuring device.

Current Input BurdenVA

Apparent-power burden presented by the measuring input to an external current transformer under manufacturer-declared conditions.

External Shunt Measurement Supported

Indicates that current can be monitored using an external measuring shunt.

Minimum Shunt Input VoltageV

Minimum supported measuring voltage across an external current shunt. UI may display the value in mV.

Maximum Shunt Input VoltageV

Maximum supported measuring voltage across an external current shunt. UI may display the value in mV.

Power Measurement Scope

Defines whether electrical power is evaluated as a total system value, per phase, or both.

Measured Power Quantities

Electrical power quantities measured or calculated by the device.

Power Flow Direction Detection Supported

Indicates that the device can distinguish the direction of active power flow.

Supported Power Flow Directions

Power-flow directions that can be measured or evaluated by the product.

Minimum Active Power MeasurementW

Lower limit of the manufacturer-declared active-power measuring range.

Maximum Active Power MeasurementW

Upper limit of the manufacturer-declared active-power measuring range.

Active Power Measurement Accuracy%

Manufacturer-declared relative accuracy of active-power measurement.

Minimum Reactive Power Measurementvar

Lower limit of the manufacturer-declared reactive-power measuring range.

Maximum Reactive Power Measurementvar

Upper limit of the manufacturer-declared reactive-power measuring range.

Reactive Power Measurement Accuracy%

Manufacturer-declared relative accuracy of reactive-power measurement.

Minimum Apparent Power MeasurementVA

Lower limit of the manufacturer-declared apparent-power measuring range.

Maximum Apparent Power MeasurementVA

Upper limit of the manufacturer-declared apparent-power measuring range.

Apparent Power Measurement Accuracy%

Manufacturer-declared relative accuracy of apparent-power measurement.

Minimum Power Factor Measurement

Lower limit of the manufacturer-declared power-factor measuring range.

Maximum Power Factor Measurement

Upper limit of the manufacturer-declared power-factor measuring range.

Power Factor Measurement Accuracy

Manufacturer-declared absolute accuracy of power-factor measurement expressed as a cos φ value difference.

Inductive / Capacitive Power Factor Discrimination Supported

Indicates that the device distinguishes inductive lagging and capacitive leading power-factor conditions.

Metering Connection Type

Overall electrical measurement connection topology of the device, distinguishing direct measurement and operation through external current, voltage, shunt, Rogowski or sensor interfaces.

Voltage Measurement Connection Method

Supported methods for connecting the voltage measuring circuit, such as direct connection or connection through an external voltage transformer.

Voltage Transformer Input Supported

Indicates that the measuring device supports voltage measurement through an external voltage transformer.

Configurable Voltage Transformer Ratio

Indicates that the voltage transformer ratio used for measurement scaling can be configured in the device.

Minimum Voltage Transformer Primary Voltage SettingV

Minimum configurable primary voltage value used for voltage-transformer measurement scaling.

Maximum Voltage Transformer Primary Voltage SettingV

Maximum configurable primary voltage value used for voltage-transformer measurement scaling.

Supported Voltage Transformer Secondary Voltages

Standard secondary voltage ratings of external voltage transformers supported by the measuring input.

Bidirectional Energy Measurement Supported

Indicates separate measurement or registration of energy flowing in both import and export directions.

Four-Quadrant Measurement Supported

Indicates support for four-quadrant measurement of active and reactive power or energy, distinguishing direction and reactive quadrant where applicable.

Per-Phase Measurement Supported

Indicates that measured electrical quantities are available separately for individual phases.

Phase-to-Phase Voltage Measurement Supported

Indicates that phase-to-phase voltage values can be measured and made available by the device.

Phase-to-Neutral Voltage Measurement Supported

Indicates that phase-to-neutral voltage values can be measured and made available by the device.

Neutral Current Measurement Supported

Indicates that current in the neutral conductor can be measured independently.

Total System Measurement Supported

Indicates that aggregate or total system values are calculated in addition to individual phase measurements.

Active Energy Measurement Supported

Indicates that the device measures or accumulates active electrical energy.

Reactive Energy Measurement Supported

Indicates that the device measures or accumulates reactive electrical energy.

Apparent Energy Measurement Supported

Indicates that the device measures or accumulates apparent electrical energy.

Imported Energy Measurement Supported

Indicates separate measurement or accumulation of imported energy.

Exported Energy Measurement Supported

Indicates separate measurement or accumulation of exported energy.

Net Energy Measurement Supported

Indicates calculation or accumulation of net energy resulting from import and export energy flow.

Supported Reactive Energy Quadrants

Reactive-energy quadrants that can be separately measured or registered.

Active Energy Accuracy Class

Manufacturer-declared accuracy class for active electrical energy measurement.

Reactive Energy Accuracy Class

Manufacturer-declared accuracy class for reactive electrical energy measurement.

Meter Reference CurrentA

Reference current Iref declared for an electricity meter where applicable.

Meter Basic CurrentA

Basic current Ib declared for a direct-connected electricity meter where applicable.

Meter Minimum CurrentA

Minimum current Imin associated with the declared metrological performance of the meter.

Meter Transition CurrentA

Transition current Itr associated with the declared metrological accuracy region of the meter.

Meter Starting CurrentA

Minimum current at which the electricity meter starts and continues energy registration under declared conditions.

Meter Maximum CurrentA

Maximum meter current Imax associated with the declared metrological current range.

Energy Pulse Output Supported

Indicates that accumulated energy can be represented by an electrical pulse output.

Active Energy Pulse Output Constantimp/kWh

Number of output pulses corresponding to one kilowatt-hour of active energy.

Reactive Energy Pulse Output Constantimp/kvarh

Number of output pulses corresponding to one kilovar-hour of reactive energy.

Pulse Output Widthms

Duration of a single energy pulse generated by the pulse output.

Pulse Output Type

Electrical implementation of the pulse output used for metering or counting.

Maximum Pulse Input FrequencyHz

Maximum accepted input pulse frequency under manufacturer-declared conditions.

Minimum Pulse Input Widthms

Minimum pulse duration reliably recognized by the pulse input.

Pulse Input Debounce Timems

Input filtering or debounce time applied to pulse or contact signals.

Minimum Pulse Input VoltageV

Minimum accepted external voltage for a voltage-operated pulse input.

Maximum Pulse Input VoltageV

Maximum accepted external voltage for a voltage-operated pulse input.

Galvanically Isolated Pulse Input

Indicates galvanic isolation between the pulse-input circuit and the relevant internal device circuitry.

Minimum Digital Input VoltageV

Minimum manufacturer-declared operating voltage of a digital input.

Maximum Digital Input VoltageV

Maximum manufacturer-declared operating voltage of a digital input.

Maximum Digital Input CurrentA

Maximum current drawn by or permitted at the digital input under declared conditions.

Minimum Neutral Current MeasurementA

Lower limit of the manufacturer-declared independent neutral-conductor current measurement range.

Maximum Neutral Current MeasurementA

Upper limit of the manufacturer-declared independent neutral-conductor current measurement range.

Neutral Current Measurement Accuracy%

Manufacturer-declared accuracy of independent neutral-conductor current measurement.

Protection and Safety7
IP Rating

Degree of enclosure protection against access to hazardous parts and ingress of solid objects and water, designated by the IP code.

IK Rating

Class of enclosure resistance to external mechanical impacts designated by the IK code.

Protection Against Direct Contact

Method or level of protection of the user against direct contact with hazardous live parts.

Finger-Safe

Indicates whether the design prevents finger access to hazardous live parts in the intended condition.

Flammability Class

Classification of a material according to its ability to ignite, sustain combustion, and cease burning under a specified test.

Glow-Wire Test Temperature°C

Temperature of the heated wire used when testing the material or product against an ignition source.

Halogen-Free

Indicates whether the product material is classified as halogen-free according to the characteristics declared by the manufacturer.

Environmental Conditions14
Minimum Operating Temperature°C

Minimum ambient temperature at which normal operation of the product is permitted.

Maximum Operating Temperature°C

Maximum ambient temperature at which normal operation of the product is permitted.

Maximum 24-Hour Average Temperature°C

Maximum permissible average ambient temperature over a consecutive 24-hour period.

Minimum Storage Temperature°C

Minimum ambient temperature permitted during storage of the product while not in operation.

Maximum Storage Temperature°C

Maximum ambient temperature permitted during storage of the product while not in operation.

Minimum Relative Humidity%

Minimum relative air humidity permitted for the declared operating or test condition.

Maximum Relative Humidity%

Maximum relative air humidity permitted for the declared operating or test condition.

Relative Humidity Reference Temperature°C

Temperature at which the corresponding relative humidity value is specified or standardized.

Non-Condensing Humidity

Indicates whether the permissible humidity value applies only to non-condensing conditions.

Maximum Installation Altitudem

Maximum altitude above sea level at which the product may be installed without exceeding the declared conditions.

Altitude Derating Required

Indicates whether the permissible product load must be reduced as installation altitude increases.

Altitude Derating Startm

Altitude above sea level above which the permissible product load must be reduced.

Vibration Resistant

Indicates whether the product's resistance to vibration has been verified under the declared conditions.

Mechanical Shock Resistant

Indicates whether the product's resistance to short-duration mechanical shocks has been verified.

Included Equipment25
Touchscreen Present

Indicates whether a touchscreen is provided for user input through the local HMI.

Local HMI Present

Indicates whether a local human-machine interface (HMI) is provided for monitoring, configuration, or control.

Display Present

Indicates whether the product has an integrated local display.

Display Type

Technology or construction type of the product's integrated display.

Display Backlight

Indicates whether the integrated display has a backlight.

Status LED Count

Number of integrated LEDs used to indicate product status or operating modes.

Documentation Included

Indicates whether documentation is included in the product's standard supply.

Installation Manual Included

Indicates whether an installation manual is included with the product.

Local Key Count

Number of integrated user keys or buttons available for local navigation, programming or control.

Display of Measured Values Supported

Indicates that current measured values can be shown on the integrated display.

Display of Diagnostic Messages Supported

Indicates that fault, warning or diagnostic messages can be shown on the local display.

Display Status Color Indication Supported

Indicates that the display changes color or uses color coding to distinguish normal, warning, fault or configuration states.

Optical Metrology LED Present

Indicates the presence of an optical metrology LED generating pulses proportional to measured energy.

Optical Metrology LED Constantimp/kWh

Number of optical metrology LED pulses corresponding to one kilowatt-hour.

Display Digit Count

Number of numeric digits that can be shown simultaneously on the primary numeric display field.

Display Line Count

Number of simultaneously visible text or measurement lines on the integrated display.

Display Characters per Line

Maximum number of alphanumeric characters displayed in one text line.

Horizontal Display Resolutionpx

Horizontal pixel resolution of a graphical integrated display.

Vertical Display Resolutionpx

Vertical pixel resolution of a graphical integrated display.

Display Diagonalmm

Physical diagonal dimension of the integrated display viewing area.

Display Page Count

Number of predefined or configurable local display pages available for measured values or device information.

Display Auto-Scroll Supported

Indicates that the device can automatically cycle through display pages or measured values.

Display Hold Function Supported

Indicates that the currently displayed measured value can be held or frozen on the local display.

Display Unit Indication Supported

Indicates that the measurement unit associated with a displayed value is shown locally.

Display Phase Identification Supported

Indicates that local measured-value presentation identifies the associated phase or conductor.

Special Features128
Minimum / Maximum Measurement Supported

Indicates whether the product stores or provides minimum and maximum values of measured quantities.

Demand Measurement Supported

Indicates whether demand calculation or measurement is supported for specified electrical quantities.

Event Log Supported

Indicates whether the product can store an internal event log.

Event Log Capacityevents

Maximum number of event records that can be stored in the product's internal log.

Real-Time Clock Present

Indicates whether an integrated real-time clock is provided for timekeeping, event time-stamping, or time-based functions.

Programmable Digital Inputs Supported

Indicates whether user-configurable functions can be assigned to one or more digital inputs.

Programmable Digital Outputs Supported

Indicates whether user-configurable functions can be assigned to one or more digital outputs.

Communication Supported

Indicates whether the product supports digital data exchange with external devices or systems.

Communication Protocols

List of supported digital data communication protocols.

Communication Interfaces

List of supported physical or logical digital communication interfaces.

Integrated Web Server

Indicates whether an integrated web server or web interface is provided for access to product functions.

Remote Configuration Supported

Indicates whether specified product settings can be read or changed remotely through a supported communication interface.

Remote Diagnostics Supported

Indicates whether diagnostic information, status data, or fault information can be obtained remotely.

Measured Value Memory Supported

Indicates whether one or more measured values can be stored, for example the latest, minimum, maximum, or a value associated with a fault event.

Relay Output Functions

Functions permanently assigned or assignable to the product relay outputs.

Firmware Updatable

Indicates that device firmware can be updated by a manufacturer-supported procedure.

RTC Backup Timeh

Manufacturer-declared duration for which the real-time clock continues to retain valid time information without normal supply voltage.

Monitoring Functions

Electrical or physical monitoring functions provided by the device, such as overvalue, undervalue, window, phase, frequency, current, power, insulation, temperature or level monitoring.

Local Configuration Supported

Indicates that device settings can be configured directly on the product using integrated controls or a local HMI.

Measured Value Memory Types

Types of measured values that can be retained by the product, such as last, minimum, maximum or fault-associated values.

Event Timestamp Supported

Indicates that stored events, warnings or faults can include a date and/or time stamp.

Trend Data Supported

Indicates that measured-value trends or historical sequences can be stored, transmitted or evaluated.

Remote Measured Value Readout Supported

Indicates that current measured values can be read by an external controller, software system or communication master.

Remote Reset Supported

Indicates whether a latched trip, fault, or alarm state can be reset remotely through a supported command or interface.

Remote Test Supported

Indicates that an internal test or test function can be initiated remotely through a supported interface.

Diagnostics via Communication Supported

Indicates that warning, fault, status or diagnostic information can be transmitted through a supported digital communication interface.

External Time Synchronization Supported

Indicates that the internal clock can be synchronized from an external radio, satellite, network or other reference time source.

External Time Synchronization Sources

External reference systems supported for automatic clock synchronization.

External Time Synchronization Antenna Supported

Indicates that an external radio or satellite time-reference antenna can be connected to the product.

Multi-Tariff Metering Supported

Indicates that energy values can be accumulated separately in multiple tariff registers.

Tariff Count

Maximum number of independent energy tariffs supported by the meter.

Tariff Switching Methods

Methods supported for selecting or switching active tariff registers.

Total Energy Register Supported

Indicates the presence of a cumulative total-energy register.

Partial Energy Register Supported

Indicates the presence of one or more partial or subtotal energy registers.

Partial Energy Register Resettable

Indicates that a partial energy register can be reset without clearing the legally relevant total-energy register.

Maximum Demand Register Supported

Indicates storage of the maximum calculated demand value.

Configurable Demand Interval

Indicates that the demand calculation interval can be configured.

Minimum Demand Intervals

Minimum configurable interval used for demand calculation.

Maximum Demand Intervals

Maximum configurable interval used for demand calculation.

Load Profile Supported

Indicates that time-series load or energy profile data can be recorded internally.

Minimum Load Profile Intervals

Minimum configurable interval between stored load-profile records.

Maximum Load Profile Intervals

Maximum configurable interval between stored load-profile records.

Load Profile Capacityrecords

Maximum number of load-profile records retained internally.

Reverse Energy Detection Supported

Indicates detection or signalling of reverse energy flow.

Non-Volatile Energy Register Memory

Indicates that accumulated energy registers are retained without normal supply voltage.

Energy Register Retention During Power Failure

Indicates that energy register values are preserved across supply interruptions.

Anti-Tamper Event Detection Supported

Indicates that the meter can detect and register manufacturer-defined tamper or manipulation events.

Local Configuration Lock Supported

Indicates that local configuration access can be intentionally restricted against unauthorized changes.

Local Configuration Lock Methods

Methods supported for restricting access to local device configuration.

Measurement Data Logging Supported

Indicates that measured electrical values can be stored internally as historical measurement records.

Measurement Data Log Capacityrecords

Maximum number of historical measurement records retained internally.

Configurable Measurement Logging Interval

Indicates that the interval between periodic measurement records can be configured.

Minimum Measurement Logging Intervals

Minimum configurable interval between periodically stored measurement records.

Maximum Measurement Logging Intervals

Maximum configurable interval between periodically stored measurement records.

Measurement Data Logging Trigger Modes

Supported conditions or commands that initiate storage of measurement records.

Measurement Data Memory Capacitybytes

Manufacturer-declared internal non-volatile memory capacity available for measurement history or logging.

Historical Data Export Supported

Indicates that stored measurement or event history can be exported from the device.

Measurement Data Export Formats

File or interchange formats supported for exporting stored measurement data.

Alarm Log Supported

Indicates that alarm occurrences are stored in a dedicated alarm history or log.

Alarm Log Capacityevents

Maximum number of alarm records retained in the dedicated alarm history.

Alarm Acknowledgement Supported

Indicates that active or stored alarms can be explicitly acknowledged by the user or supervisory system.

Maximum Demand Reset Supported

Indicates that the stored maximum demand register can be reset using a manufacturer-supported procedure.

Min/Max Value Reset Supported

Indicates that stored minimum and maximum measured values can be reset.

Supported Serial Baud Rates

Supported serial communication baud rates for interfaces such as RS-232, RS-422, RS-485 or equivalent serial buses.

Supported Serial Data Bits

Supported data-word lengths for serial communication.

Supported Serial Parity Modes

Parity modes supported by the serial communication interface.

Supported Serial Stop Bits

Supported number of stop bits in serial communication frames.

Configurable Serial Device Address

Indicates that the logical device or slave address used by a serial communication protocol can be configured.

Minimum Serial Device Address

Minimum configurable logical address on a supported serial communication network.

Maximum Serial Device Address

Maximum configurable logical address on a supported serial communication network.

Supported Ethernet Link Speeds

Supported nominal Ethernet physical-layer link speeds.

Ethernet IP Address Assignment Methods

Supported methods for assigning network-layer addresses to the Ethernet interface.

IPv6 Supported

Indicates support for Internet Protocol version 6 communication.

Wireless Communication Supported

Indicates that one or more integrated or optional wireless communication technologies are supported.

Wireless Communication Technologies

Wireless communication technologies supported by the product.

Supported Cellular Technologies

Cellular network technologies supported by the integrated or optional modem.

Supported SIM Form Factors

Physical or embedded SIM formats supported by a cellular communication module.

External Communication Antenna Supported

Indicates that an external antenna can be connected for wireless or cellular data communication.

Wireless Signal Strength Reporting Supported

Indicates that wireless or cellular signal-strength information is available locally or through communication.

Communication Gateway Function Supported

Indicates that the device can provide communication access between another device or local bus and an upstream network.

Protocol Conversion Supported

Indicates that the device can translate or bridge application data between different supported communication protocols.

Automatic Data Push Supported

Indicates that measured or logged data can be transmitted automatically without an explicit polling request.

Cloud Connectivity Supported

Indicates manufacturer-supported communication with a cloud or remote Internet service.

API Access Supported

Indicates that measurement, status or configuration data can be accessed through a documented application programming interface.

Supported API Types

Application programming interface types supported by the product or its integrated communication service.

Remote Firmware Update Supported

Indicates that firmware can be updated through a supported local or remote data communication interface.

Communication Watchdog Supported

Indicates that loss or inactivity of a communication link can be detected by an internal communication watchdog.

Configurable Communication Timeout

Indicates that the timeout used to detect communication loss or inactivity can be configured.

Minimum Communication Timeouts

Minimum configurable communication timeout.

Maximum Communication Timeouts

Maximum configurable communication timeout.

User Authentication Supported

Indicates that access to network, web, API or remote configuration functions can require authenticated user credentials.

Encrypted Communication Supported

Indicates support for encrypted data communication through one or more manufacturer-supported communication services.

Supported TLS Versions

Transport Layer Security protocol versions supported for protected network communication.

Role-Based Access Control Supported

Indicates that user permissions can be differentiated by user role or authorization level.

Security Event Logging Supported

Indicates that security-relevant events such as authentication failures or configuration access can be recorded.

Secure Boot Supported

Indicates that the device verifies the integrity or authenticity of executable firmware during startup.

Signed Firmware Update Supported

Indicates that firmware update packages are cryptographically authenticated before installation.

Communication Failure Alarm Supported

Indicates that loss of an expected communication connection can generate a local or remote alarm or diagnostic condition.

Pulse Input Types

Electrical pulse-input interfaces supported by the device.

Configurable Pulse Input Scaling

Indicates that the engineering quantity represented by each received pulse can be configured.

Pulse Input Scaling Factor

Numeric scaling factor used to convert accumulated input pulses into the configured engineering quantity.

Pulse Input Scaling Unit

Engineering unit assigned to the configurable pulse-input scaling, for example kWh, kvarh, m3 or another manufacturer-supported unit.

Digital Input Functions

Functions that can be assigned or are dedicated to integrated digital inputs.

Digital Output Functions

Functions that can be assigned or are dedicated to integrated digital outputs.

Time-Averaged Measurement Supported

Indicates that measured quantities can be averaged over a defined time interval, independently of the underlying electrical measurement principle.

Configurable Averaging Interval

Indicates that the time interval used for statistical averaging of measured values can be configured.

Minimum Averaging Intervals

Minimum configurable time interval used for averaging measured values.

Maximum Averaging Intervals

Maximum configurable time interval used for averaging measured values.

Min/Max Timestamp Supported

Indicates that stored minimum and maximum measured values include the time at which the extreme value occurred.

Phase Sequence Indication Supported

Indicates that the detected phase sequence or phase rotation direction can be presented locally or through communication.

Demand Quantities

Electrical quantities for which interval demand can be calculated or registered.

Demand Calculation Methods

Demand calculation algorithms supported by the measuring device.

Demand Subinterval Supported

Indicates that a demand interval may be divided into shorter subintervals for rolling or sliding demand calculation.

Minimum Demand Subintervals

Minimum configurable demand-calculation subinterval.

Maximum Demand Subintervals

Maximum configurable demand-calculation subinterval.

Predicted Demand Supported

Indicates calculation of a projected demand value before completion of the current demand interval.

Measurement Alarm Supported

Indicates that measured or calculated quantities can be compared with configured limits to generate alarms or status conditions.

Alarm Output Assignment Supported

Indicates that configured measurement alarms can be assigned to available relay, digital or equivalent outputs.

Input Wiring Error Detection Supported

Indicates that the measuring device can detect manufacturer-defined wiring errors affecting its voltage or current measurement inputs.

CT Polarity Error Detection Supported

Indicates that incorrect current-transformer polarity or reversed current measurement direction can be detected.

Phase Assignment Error Detection Supported

Indicates that an incorrect relationship between voltage and current phase channels can be detected.

Measurement Overrange Indication Supported

Indicates explicit indication when an input or calculated measured quantity exceeds its valid measurement range.

Measurement Underrange Indication Supported

Indicates explicit indication when an input or measured quantity is below its valid or usable measurement range.

RTC Backup Status Monitoring Supported

Indicates that the condition of the battery, capacitor or other backup source used for the real-time clock can be monitored or diagnosed.

Memory Integrity Monitoring Supported

Indicates that the device can detect corruption or integrity failures affecting stored configuration, measurement or metrological data.

Energy Cost Calculation Supported

Indicates that measured energy consumption can be converted into an estimated monetary cost using user-configurable tariff information.

CO2 Emissions Calculation Supported

Indicates that measured energy consumption can be converted into an estimated carbon-dioxide emission quantity.

Configurable CO2 Conversion Factor

Indicates that the energy-to-CO2 conversion factor used for emissions calculation can be configured.

Standards and Compliance63
Conformity Regions

Regions or markets for which the manufacturer declares regulatory or certification compliance of the product.

Certification and Conformity Marks

Certification, market-approval, or conformity marks applicable to the product.

Primary Product Standard

Primary normative document or standard according to which the manufacturer classifies or assesses the product.

Additional Standards

Additional normative documents and standards declared by the manufacturer as applicable to the product.

Declaration of Conformity Available

Indicates whether an official declaration of conformity is available for the product.

Certificate Available

Indicates whether a certificate relating to the declared certification or conformity of the product is available.

Certificate Number

Identification number of the certificate relating to the product or its certified version.

Certification Body

Name of the organization that issued the certificate or performed the relevant conformity assessment.

CE Marked

Indicates whether the CE marking is applied to the product where applicable.

EAC Marked

Indicates whether the EAC marking is applied to the product where applicable.

cULus Marked

Indicates whether the cULus mark is applied to the product where applicable.

CSA Certified

Indicates whether the product has a declared CSA certification or recognition status.

RoHS Compliant

Indicates whether product compliance with applicable RoHS restrictions on hazardous substances has been declared.

REACH Compliant

Indicates whether the manufacturer declares compliance of the product with applicable REACH Regulation requirements.

Legal Metrology Applicable

Indicates that the product is intended for a measurement application subject to legal metrology requirements.

Legal-for-Trade Approved

Indicates manufacturer-declared approval for legally regulated or commercial measurement use in at least one applicable jurisdiction.

Revenue Metering Suitable

Indicates suitability for revenue or billing energy metering where the manufacturer explicitly declares such use.

MID 2014/32/EU Compliant

Compliance with Directive 2014/32/EU on measuring instruments where applicable.

MID MI-003 Applicable

Indicates that the product falls within the MID MI-003 category for active electrical energy meters.

MID Conformity Assessment Procedures

MID conformity assessment procedures under which the active electrical energy meter may be assessed.

Metrological Marking Present

Indicates that legally required metrological marking is applied to the product where applicable.

Supplementary Metrology Marking Present

Indicates presence of the supplementary metrology marking required by the applicable European measuring-instrument conformity scheme.

Notified Body Number

Identification number of the notified body associated with the applicable conformity assessment or metrological marking.

Metrological Type Approval Available

Indicates that a type-approval or equivalent legal-metrology approval exists for the product.

Metrological Type Approval Number

Manufacturer- or authority-declared identifier of the applicable legal-metrology type approval.

Metrological Seal Required

Indicates that metrological sealing is required to protect legally relevant settings or measurement access.

Metrological Sealing Supported

Indicates that dedicated provisions exist for applying a metrological seal.

Factory Metrologically Sealed

Indicates that the catalog product is normally supplied with manufacturer-applied metrological sealing where applicable.

Calibration Supported

Indicates that the measuring function can be calibrated using a manufacturer-defined procedure.

Factory Calibrated

Indicates that the product is calibrated by the manufacturer before delivery.

Calibration Certificate Available

Indicates that a calibration certificate can be supplied for the product.

Recommended Calibration Intervalmonths

Manufacturer-recommended interval between periodic calibrations, where such an interval is specified.

Field Calibration Supported

Indicates that calibration can be performed in the installed location without factory return.

User Calibration Supported

Indicates that an authorized user can execute a manufacturer-supported calibration procedure.

Zero Calibration Supported

Indicates support for adjustment or calibration of measurement zero offset.

Span Calibration Supported

Indicates support for gain or span calibration using a reference measurement value.

Calibration Point Count

Number of calibration points supported by the manufacturer-defined calibration procedure.

Calibration Access Protected

Indicates that access to calibration parameters or procedures is protected against unauthorized changes.

Measurement Accuracy Verification Supported

Indicates that the manufacturer provides a defined procedure or test facility for verifying measurement accuracy.

Metrological Self-Test Supported

Indicates an internal self-test covering legally or technically relevant measurement functions.

Metrological Event Log Supported

Indicates storage of events relevant to metrological integrity, legal settings or protected measurement functions.

Metrological Parameter Change Log Supported

Indicates that changes to legally or metrologically relevant configuration parameters are recorded.

Metrological Parameters Write Protected

Indicates that metrologically relevant parameters are protected against unauthorized modification.

Billing Registers Write Protected

Indicates that legally or commercially relevant accumulated billing registers cannot be arbitrarily modified.

IEC 62052-11 Compliant

Compliance with IEC 62052-11 general requirements, tests and test conditions for electricity metering equipment.

EN IEC 62052-11 Compliant

Compliance with the European adoption of IEC 62052-11 for electricity metering equipment.

IEC 62052-31 Compliant

Compliance with IEC 62052-31 product safety requirements for electrical energy metering equipment.

EN IEC 62052-31 Compliant

Compliance with the European adoption of IEC 62052-31 metering-equipment safety requirements.

IEC 62053-21 Compliant

Compliance with IEC 62053-21 requirements applicable to static meters for active electrical energy.

EN IEC 62053-21 Compliant

Compliance with the European adoption of IEC 62053-21 for static active-energy meters.

IEC 62053-22 Compliant

Compliance with IEC 62053-22 requirements applicable to higher-accuracy static active-energy meters.

EN IEC 62053-22 Compliant

Compliance with the European adoption of IEC 62053-22.

IEC 62053-23 Compliant

Compliance with IEC 62053-23 requirements applicable to static reactive-energy meters.

EN IEC 62053-23 Compliant

Compliance with the European adoption of IEC 62053-23.

IEC 62053-24 Compliant

Compliance with IEC 62053-24 requirements applicable to static reactive-energy measurement at fundamental frequency.

EN IEC 62053-24 Compliant

Compliance with the European adoption of IEC 62053-24.

IEC 62053-31 Compliant

Compliance with IEC 62053-31 requirements applicable to pulse-output devices for electrical energy meters.

EN IEC 62053-31 Compliant

Compliance with the European adoption of IEC 62053-31 for meter pulse outputs.

IEC 62056-21 Compliant

Compliance with IEC 62056-21 requirements for local data exchange with electricity meters.

EN IEC 62056-21 Compliant

Compliance with the European adoption of IEC 62056-21.

EN 50470-1 Compliant

Compliance with EN 50470-1 requirements applicable to electricity metering equipment.

EN 50470-3 Compliant

Compliance with EN 50470-3 requirements applicable to static active-energy meters.

OIML R 46 Compliant

Compliance with OIML R 46 recommendations applicable to active electrical energy meters.

Logistics9
Gross Weightkg

Mass of the product together with its individual packaging and the accessories included in it.

Package Widthmm

External horizontal dimension of the product's individual package.

Package Heightmm

External vertical dimension of the product's individual package.

Package Depthmm

External depth dimension of the product's individual package.

Packaging Type

Design type of the product's individual or transport packaging.

Net Weightkg

Mass of the product itself, excluding transport packaging, additional accessories, and external equipment.

Country of Origin

Country of origin of the goods declared for customs or commercial purposes.

HS Code

Commodity code under the international Harmonized Commodity Description and Coding System.

Combined Nomenclature Code

Commodity code under the Combined Nomenclature of the European Union.