Device description

Autotransformer

Transformer with an electrically common winding section for stepping AC voltage up or down or providing adjustable AC voltage.

An autotransformer uses an electrically common winding, so power is transferred between input and output through both conductive and electromagnetic paths.

Unlike a conventional isolation transformer, an autotransformer generally does not provide galvanic separation between input and output circuits.

The device may operate in step-up or step-down mode. Adjustable versions use winding taps or a moving sliding contact and may provide stepped or continuous adjustment.

Motorized and servo-driven models allow remote voltage adjustment, including under load where this application is permitted by the manufacturer.

Selection criteria include adjustment range, power, common and series winding portions, adjustment method, under-load operation, sliding-contact design, and compliance with IEC 61558-2-13.

Components in this subcategory

Step-up, step-down, adjustable, motorized, and servo-driven autotransformers.

Available parameters

Autotransformer

301 parameters
General6
Product Series

Commercial or technical designation of a manufacturer's product family sharing a common design and compatible characteristics.

Application

Range of tasks and systems for which the manufacturer recommends the component.

Intended Use

Primary function of the device and its intended use as defined by its design and the manufacturer's documentation.

Installation Location

Permissible installation location of the product: indoors, outdoors, in a technical area, or as part of equipment.

Installation Environment

Environmental conditions under which installation and operation of the product are permitted.

Orientation

Permissible spatial orientation of the component during installation and operation.

Dimensions3
Widthmm

External horizontal dimension of the product between its outermost lateral points.

Heightmm

External vertical dimension of the product from its lowest to its highest point.

Depthmm

External distance between the foremost and rearmost surfaces of the product.

Materials and Finish25
Magnetic Core Construction

Mechanical and magnetic construction form of the transformer core.

Magnetic Core Material

Magnetic material used for the transformer core.

Core Cross-Section Areamm²

Effective or manufacturer-declared magnetic core cross-sectional area.

Rated Magnetic Flux DensityT

Manufacturer-declared magnetic flux density at the specified rated operating condition.

Primary Winding Conductor Material

Electrical conductor material used for the primary winding.

Secondary Winding Conductor Material

Electrical conductor material used for the secondary winding.

Primary Winding Conductor Form

Physical form of the conductor used to manufacture the primary winding.

Secondary Winding Conductor Form

Physical form of the conductor used to manufacture the secondary winding.

Winding Insulation Materials

Electrical insulation materials used directly in or between transformer windings.

Winding Impregnation Present

Indicates that the transformer windings are impregnated during manufacture.

Winding Impregnation Method

Manufacturing method used to impregnate transformer windings.

Winding Impregnation Material

General type of resin, varnish or compound used to impregnate the transformer winding assembly.

Transformer Encapsulated

Indicates that all or a substantial portion of the transformer assembly is encapsulated or potted in an insulating compound.

Encapsulation Method

Manufacturing method used to encapsulate or pot the transformer assembly.

Encapsulation Material

General material used for transformer encapsulation or potting.

Bobbin Present

Indicates that the transformer winding is manufactured on a bobbin or coil former.

Bobbin Material

Material used for the winding bobbin or coil former.

Core Clamp Present

Indicates that a dedicated clamp, strap or bracket is used to mechanically secure the magnetic core.

Core Clamp Material

Material used for the principal mechanical core clamp, strap or bracket.

Sliding Contact Material

Principal material of the moving electrical contact or brush used by a variable autotransformer.

Color

Primary visually perceived colour of the product's external surface.

RAL Color

Designation of the product's primary surface colour according to the RAL colour system.

Surface Finish

Type of final surface finish of the product determining its appearance and service properties.

Material

Primary material from which the product is manufactured.

Material Grade

Grade, alloy, class, or technical designation of the product's primary material.

Mounting and Installation49
Primary Connection Type

Physical connection interface used for the primary transformer winding.

Secondary Connection Type

Physical connection interface used for the secondary transformer winding.

Primary Terminal Count

Number of electrically accessible primary-side connection terminals or leads.

Secondary Terminal Count

Number of electrically accessible secondary-side connection terminals or leads.

Primary Lead Lengthmm

Manufacturer-declared free length of primary-side flying leads where present.

Secondary Lead Lengthmm

Manufacturer-declared free length of secondary-side flying leads where present.

Primary Lead Cross-Sectionmm²

Nominal conductor cross-section of permanently attached primary-side leads.

Secondary Lead Cross-Sectionmm²

Nominal conductor cross-section of permanently attached secondary-side leads.

Lead Wire Insulation Material

Principal insulation material used on permanently attached transformer lead wires.

PE Connection Provision

Indicates whether a dedicated point or terminal is provided for connection of the PE protective conductor.

Number of PE Terminals

Number of PE terminals included in the product's standard equipment or provided for the specific version.

Functional Earth Connection

Indicates whether a separate functional earth connection is provided that does not replace the PE protective connection.

DIN Rail Mounting Supported

Indicates whether the design provides for mounting equipment on a DIN rail.

Compatible DIN Rail Types

List of DIN rail profiles with which the product is mechanically compatible.

DIN Rail Orientation

Spatial orientation of the DIN rail relative to the product in its intended installed position.

Mounting Surface

Type of surface or supporting base to which the product may be fixed.

Number of Mounting Holes

Number of holes provided in the product for mechanical fixing.

Mounting Hole Diametermm

Diameter of the hole provided for a fixing element used when mounting the product.

Mounting Hole Shape

Geometric shape of the hole intended for mechanical fixing of the product.

Horizontal Mounting Hole Spacingmm

Distance between the centres of mounting holes in the horizontal direction.

Vertical Mounting Hole Spacingmm

Distance between the centres of mounting holes in the vertical direction.

Mounting Pattern Widthmm

Horizontal dimension of the mounting pattern between the outermost fixing points of the product.

Mounting Pattern Heightmm

Vertical dimension of the mounting pattern between the outermost fixing points of the product.

Mounting Screw Size

Size designation of the screw, bolt, or other threaded fastener used for mounting the product.

Mounting Thread

Designation of the thread provided in the product's mounting holes or fixing elements.

Mounting Tightening TorqueNm

Tightening torque recommended or permitted for fasteners during product installation.

Anti-Vibration Mounting Supported

Indicates whether the product can be installed using vibration isolators or other anti-vibration elements.

Terminal Tightening TorqueNm

Tightening torque specified by the manufacturer for a screw or bolted terminal connection.

Terminal Screw Thread

Thread designation of the screw used in the conductor clamping mechanism, for example M2.5, M3, M4, or another manufacturer-declared designation.

Terminal Screw Head Type

Drive geometry of the screw head used to clamp the conductor in the terminal block.

Terminal Screwdriver Size

Size or designation of the screwdriver, bit, or other tool required to operate the terminal screw.

Terminal Bolt Diametermm

Nominal diameter of the bolt or threaded stud used for electrical connection of the cable lug.

Terminal Bolt Lengthmm

Usable or manufacturer-declared length of the bolt or threaded stud used for the electrical connection.

Terminal Bolt Count per Connection Point

Number of electrical connection bolts or threaded studs provided for one connection point.

Minimum Terminal Tightening TorqueNm

Minimum tightening torque of the terminal screw, bolt, or nut declared by the manufacturer where a permissible range is specified.

Maximum Terminal Tightening TorqueNm

Maximum tightening torque of the terminal screw, bolt, or nut declared by the manufacturer where a permissible range is specified.

Captive Terminal Nut

Indicates whether the terminal connection nut is retained by the design to prevent it from falling out when loosened.

Tool-Free Conductor Connection

Indicates whether normal conductor connection can be performed without using a separate hand tool.

Conductor Release Method

Method used to release and remove a connected conductor from the connection point.

Conductor Release Tool Required

Indicates whether a separate tool is required to release the connected conductor.

Conductor Release Tool Type

Type, size, or designation of the tool declared by the manufacturer for actuating the conductor-release mechanism.

Minimum Ventilation Clearance Abovemm

Minimum unobstructed installation clearance required above the product for ventilation or heat dissipation.

Minimum Ventilation Clearance Belowmm

Minimum unobstructed installation clearance required below the product for ventilation or heat dissipation.

Minimum Ventilation Clearance Leftmm

Minimum unobstructed installation clearance required on the left side for normal cooling.

Minimum Ventilation Clearance Rightmm

Minimum unobstructed installation clearance required on the right side for normal cooling.

Minimum Ventilation Clearance Frontmm

Minimum unobstructed installation clearance required in front of the product for normal cooling.

Minimum Ventilation Clearance Rearmm

Minimum unobstructed installation clearance required behind the product for normal cooling.

Mounting Type

Installation arrangement permitted by the product design, such as wall-mounted, flush-mounted, floor-mounted, or another specified mounting type.

Mounting Method

Method used to mechanically secure the product to a support, surface, or load-bearing structure.

Electrical Parameters83
Rated Primary VoltageV

Rated electrical voltage of the primary winding or primary side of a transformer or voltage-transforming device under manufacturer-declared conditions.

Rated Secondary VoltageV

Rated electrical voltage of the secondary winding or secondary side of a transformer or voltage-transforming device under manufacturer-declared conditions.

Rated Primary CurrentA

Rated electrical current of the primary winding or primary side under manufacturer-declared conditions.

Rated Secondary CurrentA

Rated electrical current of the secondary winding or secondary side under manufacturer-declared conditions.

Transformation Ratio

Manufacturer-declared transformation ratio between the relevant primary and secondary electrical quantities.

Rated Output Apparent PowerVA

Continuous rated apparent output power for AC-output power conversion equipment.

Rated FrequencyHz

AC frequency assigned to the product for normal operating conditions.

Minimum FrequencyHz

Lower limit of the electrical network or signal frequency at which product operation is permitted.

Maximum FrequencyHz

Upper limit of the electrical network or signal frequency at which product operation is permitted.

Efficiency%

Manufacturer-declared power conversion efficiency at the specified operating point.

Inrush CurrentA

Peak input current occurring during energization or startup of the device.

Inrush Current Durationms

Manufacturer-declared duration associated with the specified input inrush current.

No-Load Power ConsumptionW

Input power consumed while the device is energized and operating without an external output load.

No-Load CurrentA

Input current drawn by the energized transformer with the secondary unloaded under specified conditions.

No-Load Current Percentage%

No-load input current expressed as a percentage of the relevant rated current.

No-Load Secondary VoltageV

Secondary voltage measured under the manufacturer-declared no-load condition.

Output Voltage Tolerance%

Permissible deviation of output voltage from its declared nominal value under specified operating conditions.

Load Regulation%

Change in output voltage caused by variation of output load within the manufacturer-declared operating range.

Primary Winding Count

Number of electrically distinguishable primary windings provided by the transformer.

Secondary Winding Count

Number of electrically distinguishable secondary windings provided by the transformer or transformer-based device.

Primary Winding Connection

Electrical connection arrangement of the primary winding or primary phase windings.

Secondary Winding Connection

Electrical connection arrangement of the secondary winding or secondary phase windings.

Transformer Vector Group

Manufacturer-declared transformer vector group designation, for example Dyn11, Yyn0 or Dd0.

Primary-to-Secondary Phase Displacement°

Electrical phase displacement between the relevant primary and secondary voltage systems.

Primary Winding ResistanceOhm

Manufacturer-declared DC resistance of the primary winding under the stated reference conditions.

Secondary Winding ResistanceΩ

Manufacturer-declared DC resistance of the secondary winding under the stated reference conditions.

Primary Windings Independently Accessible

Indicates that multiple primary windings have separately accessible terminals.

Primary Windings Isolated from Each Other

Indicates that multiple primary windings are electrically isolated from one another.

Primary Winding Interconnection Options

Manufacturer-approved methods of interconnecting multiple accessible primary windings.

Secondary Windings Independently Accessible

Indicates that multiple secondary windings have separately accessible terminals.

Secondary Windings Isolated from Each Other

Indicates that multiple secondary windings are electrically isolated from one another.

Secondary Winding Interconnection Options

Manufacturer-approved methods of interconnecting multiple accessible secondary windings.

Center-Tapped Secondary Supported

Indicates that the secondary winding provides an accessible electrical centre tap.

Center Tap VoltageV

Nominal voltage between the secondary centre tap and either corresponding winding end where declared.

Short-Circuit Impedance%

Transformer short-circuit impedance expressed as a percentage of rated voltage under manufacturer-declared reference conditions.

Short-Circuit Output CurrentA

Manufacturer-declared secondary output current under the specified short-circuit condition.

Load Loss at Rated LoadW

Manufacturer-declared load-dependent transformer losses at rated load and specified reference temperature.

Total Loss at Rated LoadW

Total manufacturer-declared transformer power loss at rated load under specified reference conditions.

Magnetizing InductanceH

Manufacturer-declared magnetizing inductance referred to the specified transformer winding.

Leakage InductanceH

Manufacturer-declared transformer leakage inductance referred to the specified winding or measurement condition.

Input Phase Count

Number of AC phases used by the electrical input of the product.

Output Phase Count

Number of AC phases provided by the electrical output of the product.

Input Phase Connection

Electrical phase and neutral connection arrangement used at the AC input.

Output Phase Connection

Electrical phase and neutral connection arrangement provided at the AC output.

Neutral Input Required

Indicates that a neutral conductor is required for the manufacturer-declared input connection.

Neutral Output Available

Indicates that the AC output provides an accessible neutral conductor or neutral terminal.

Input-to-Output Galvanic Isolation

Indicates that galvanic isolation is provided between the relevant electrical input and output circuits of the product.

Safe Isolation Present

Indicates that the manufacturer declares safe electrical separation between the relevant input and output circuits.

Rated Insulation VoltageV

Voltage with reference to which the product's insulation clearances and dielectric properties are specified.

Rated Impulse Withstand VoltagekV

Peak value of an impulse voltage of specified waveform that the product insulation must withstand without breakdown.

Dielectric Test VoltageV

Test voltage applied to verify the dielectric strength of the product insulation.

Minimum Insulation ResistanceMΩ

Minimum permissible insulation resistance between the specified electrically separated parts.

Insulation Type

Type of electrical insulation used, considered in terms of its protective function and construction.

Insulation Thermal Class

Manufacturer-declared thermal class of the electrical insulation system or insulation material.

Primary Voltage Taps Supported

Indicates that selectable voltage taps are provided on the primary winding.

Primary Voltage Tap Count

Number of selectable primary winding voltage tap positions.

Minimum Primary Tap Range%

Minimum primary tap deviation relative to the nominal primary winding voltage.

Maximum Primary Tap Range%

Maximum primary tap deviation relative to the nominal primary winding voltage.

Primary Voltage Tap Step%

Nominal percentage voltage step between adjacent primary tap positions.

Secondary Voltage Taps Supported

Indicates that selectable voltage taps are provided on the secondary winding.

Secondary Voltage Tap Count

Number of selectable secondary winding voltage tap positions.

Minimum Secondary Tap Range%

Minimum secondary tap deviation relative to nominal secondary winding voltage.

Maximum Secondary Tap Range%

Maximum secondary tap deviation relative to nominal secondary winding voltage.

Secondary Voltage Tap Step%

Nominal percentage voltage step between adjacent secondary tap positions.

Tap Adjustment Method

Manufacturer-approved method used to select or change transformer winding taps.

Multiple Nominal Input Voltages Supported

Indicates that the product can be configured for more than one nominal input or primary voltage.

Selectable Nominal Input Voltage Count

Number of discrete nominal input or primary voltage configurations supported by the product.

Input Voltage Selection Method

Method used to select between supported nominal input or primary voltages.

Multiple Nominal Output Voltages Supported

Indicates that the product can provide more than one selectable nominal output or secondary voltage.

Selectable Nominal Output Voltage Count

Number of discrete nominal output or secondary voltage configurations supported by the product.

Output Voltage Selection Method

Method used to select between supported nominal output or secondary voltages.

Autotransformer Configuration

Electrical and adjustment configuration of the autotransformer.

Buck Operation Supported

Indicates that the autotransformer can provide an output voltage lower than its applicable input voltage.

Boost Operation Supported

Indicates that the autotransformer can provide an output voltage higher than its applicable input voltage.

Voltage Adjustment Method

Electrical or electromechanical method used to adjust transformer output voltage.

Adjustment Drive Types

Mechanical or powered drive methods supported for operating the voltage adjustment mechanism.

Continuous Voltage Adjustment Supported

Indicates that output voltage can be adjusted continuously rather than only between discrete tap positions.

Voltage Adjustment Under Load Supported

Indicates that the manufacturer permits normal voltage adjustment while the autotransformer supplies a load.

Voltage Adjustment Step Count

Number of discrete selectable voltage adjustment positions where the adjustment mechanism is stepped.

Common Winding Rated VoltageV

Rated voltage applicable to the common electrically shared section of an autotransformer winding.

Series Winding Rated VoltageV

Rated voltage applicable to the series portion of an autotransformer winding.

Autotransformer Conductively Transferred PowerVA

Manufacturer-declared portion of apparent power transferred directly through the electrically common winding connection.

Autotransformer Inductively Transferred PowerVA

Manufacturer-declared portion of apparent power transferred through transformer electromagnetic coupling.

Protection and Safety21
Electrical Protection Class

Class of protection against electric shock determined by the product design and protective connection method.

Integrated Overtemperature Protection

Indicates that the product incorporates protection against excessive internal, component or monitored temperature.

Transformer Thermal Protection Types

Thermal protection or winding-temperature sensing technologies incorporated in the transformer.

Thermal Protection Trip Temperature°C

Temperature at which the integrated transformer thermal protection device operates.

Thermal Protection Reset Type

Reset behaviour of the integrated transformer thermal protection device after operation.

Transformer Short-Circuit Protection Classification

Manufacturer-declared transformer classification describing behaviour under output short-circuit conditions.

Earth Leakage CurrentA

Manufacturer-declared current flowing from the product electrical circuits to protective earth under the specified operating condition.

Touch CurrentA

Manufacturer-declared current that may flow through a person or measuring network when touching accessible conductive parts under the specified condition.

Protective Earth Connection Required

Indicates that connection to protective earth is required for the declared electrical safety or operating conditions.

Pollution Degree

Degree of pollution of the surrounding microenvironment considered when selecting insulation distances and product characteristics.

Corrosion Category

Environmental corrosivity category for which resistance of the product material or protective coating is declared.

Salt Spray Resistanceh

Duration of salt-spray testing withstood by the product or coating under the declared conditions.

Suitable for Salt Atmosphere

Indicates whether the product may be operated in an atmosphere with elevated salt content.

Halogen-Free

Indicates whether the product material is classified as halogen-free according to the characteristics declared by the manufacturer.

IP Rating

Degree of enclosure protection against access to hazardous parts and ingress of solid objects and water, designated by the IP code.

IK Rating

Class of enclosure resistance to external mechanical impacts designated by the IK code.

Protection Against Direct Contact

Method or level of protection of the user against direct contact with hazardous live parts.

Finger-Safe

Indicates whether the design prevents finger access to hazardous live parts in the intended condition.

Touch-Safe

Indicates whether the design provides protection against accidental contact with hazardous live parts.

Flammability Class

Classification of a material according to its ability to ignite, sustain combustion, and cease burning under a specified test.

Glow-Wire Test Temperature°C

Temperature of the heated wire used when testing the material or product against an ignition source.

Environmental Conditions56
Winding Temperature RiseK

Manufacturer-declared winding temperature rise above the specified ambient temperature at the stated operating condition.

Cooling Method

Primary cooling method used by the product during normal operation.

Maximum Acoustic Noise LeveldB(A)

Maximum manufacturer-declared acoustic noise level under the specified operating and measurement conditions.

Minimum Installation Temperature°C

Minimum ambient temperature at which the manufacturer permits installation of the product.

Maximum Installation Temperature°C

Maximum ambient temperature at which the manufacturer permits installation of the product.

Temperature Cycling Resistant

Indicates whether the product's resistance to repeated temperature cycling has been verified.

Temperature Cycle Minimum°C

Lower cycle temperature used during temperature-cycling testing.

Temperature Cycle Maximum°C

Upper cycle temperature used during temperature-cycling testing.

Temperature Cycle Count

Number of temperature cycles performed or required in the relevant test.

Thermal Shock Resistant

Indicates whether the product's resistance to rapid temperature changes between specified levels has been verified.

Thermal Shock Temperature DifferenceK

Temperature difference between exposure levels during thermal-shock testing of the product.

Relative Humidity Reference Temperature°C

Temperature at which the corresponding relative humidity value is specified or standardized.

Humidity Condition

Nature of the humidity conditions for which product operation or resistance is declared.

Condensation Resistant

Indicates whether the product is intended for operation where condensation may occur under the declared conditions.

Condensation Condition

Condensation or non-condensation conditions permitted during product operation.

Humidity Cycling Resistant

Indicates whether the product's resistance to cyclic humidity changes has been verified.

Humidity Cycle Test Durationh

Duration of product testing under cyclic humidity conditions.

Climatic Environment

Types of climatic environment for which the manufacturer intends the product to be operated.

Minimum Vibration FrequencyHz

Lower limit of vibration frequency applied or permitted in the relevant test.

Maximum Vibration FrequencyHz

Upper limit of vibration frequency applied or permitted in the relevant test.

Vibration Accelerationm/s²

Amplitude or test-method-specified acceleration of vibration applied during product testing.

Vibration Displacementmm

Amplitude of mechanical displacement under low-frequency vibration.

Vibration Test Durationh

Duration of vibration exposure during the specified product test.

Vibration Test Axes

Spatial axes along which vibration testing of the product is performed.

Shock Accelerationm/s²

Maximum acceleration generated during mechanical shock testing of the product.

Shock Durationms

Duration of an individual mechanical shock pulse during product testing.

Shock Count per Axis

Number of shock impacts applied along each test axis.

Shock Test Axes

Spatial axes along which mechanical shock testing of the product is performed.

Mean Time Between Failuresh

Manufacturer-declared or calculated mean time between failures under specified reference conditions.

MTBF Reference Temperature°C

Ambient or component reference temperature associated with the declared MTBF value.

MTBF Prediction Method

Standard, handbook or manufacturer methodology used to calculate or predict MTBF.

Failure RateFIT

Predicted or declared failure rate expressed in failures per billion operating hours.

Design Service Lifeh

Manufacturer-declared design or expected operating service life under specified reference conditions.

Maintenance-Free

Indicates that scheduled preventive maintenance is not required during normal manufacturer-declared service life.

Preventive Maintenance Intervalh

Recommended operating interval between scheduled preventive maintenance activities.

IEC 60721 Climatic Class

Manufacturer-declared climatic environmental classification according to the applicable IEC 60721 series.

IEC 60721 Chemical Class

Manufacturer-declared chemically active substance classification according to the applicable IEC 60721 series.

IEC 60721 Mechanical Class

Manufacturer-declared mechanical environmental classification according to the applicable IEC 60721 series.

Minimum Operating Temperature°C

Minimum ambient temperature at which normal operation of the product is permitted.

Maximum Operating Temperature°C

Maximum ambient temperature at which normal operation of the product is permitted.

Maximum 24-Hour Average Temperature°C

Maximum permissible average ambient temperature over a consecutive 24-hour period.

Minimum Storage Temperature°C

Minimum ambient temperature permitted during storage of the product while not in operation.

Maximum Storage Temperature°C

Maximum ambient temperature permitted during storage of the product while not in operation.

Minimum Transport Temperature°C

Minimum ambient temperature permitted during transportation of the product.

Maximum Transport Temperature°C

Maximum ambient temperature permitted during transportation of the product.

Temperature Derating Required

Indicates whether permissible electrical or thermal loading must be reduced as temperature changes.

Temperature Derating Start°C

Temperature above which the permissible product load must be reduced.

Temperature Derating Curve Available

Indicates whether the manufacturer has published the relationship between permissible product load and temperature.

Minimum Relative Humidity%

Minimum relative air humidity permitted for the declared operating or test condition.

Maximum Relative Humidity%

Maximum relative air humidity permitted for the declared operating or test condition.

Non-Condensing Humidity

Indicates whether the permissible humidity value applies only to non-condensing conditions.

Maximum Installation Altitudem

Maximum altitude above sea level at which the product may be installed without exceeding the declared conditions.

Altitude Derating Required

Indicates whether the permissible product load must be reduced as installation altitude increases.

Altitude Derating Startm

Altitude above sea level above which the permissible product load must be reduced.

Vibration Resistant

Indicates whether the product's resistance to vibration has been verified under the declared conditions.

Mechanical Shock Resistant

Indicates whether the product's resistance to short-duration mechanical shocks has been verified.

Included Equipment6
Anti-Vibration Mounts Included

Indicates whether vibration isolators or anti-vibration mounts are included in the standard supply.

Terminal Markers Included

Indicates whether terminal markers are included in the product's standard equipment.

Terminal Marker Count

Number of terminal markers included in the product's standard equipment or provided for the specific version.

Documentation Included

Indicates whether documentation is included in the product's standard supply.

Installation Manual Included

Indicates whether an installation manual is included with the product.

Terminal Diagram Included

Indicates whether a terminal diagram is included with the product.

Special Features14
Voltage Reconfiguration Under Load Supported

Indicates that the manufacturer permits the applicable input or output voltage configuration to be changed while the product remains energized and loaded.

Field-Reconfigurable Winding Connections

Indicates that winding connections can be reconfigured in the field according to manufacturer instructions.

Transformer Duty Type

Manufacturer-declared operating duty for which the transformer is rated.

Short-Time Duty Durations

Maximum continuous energized operating duration associated with a declared short-time duty rating.

Intermittent Duty Cycle%

Percentage of the operating cycle during which the transformer may remain energized or loaded under the declared intermittent duty.

Intermittent Duty Periods

Total cycle period associated with the declared intermittent transformer duty.

Electrostatic Screen Present

Indicates that an electrostatic screen is provided between transformer windings or between a winding and other conductive parts.

Electrostatic Screen Connection

Manufacturer-declared connection arrangement for the transformer electrostatic screen.

Remote Voltage Adjustment Supported

Indicates that the output-voltage adjustment mechanism can be operated remotely.

Servo Control Supported

Indicates that a servo-controlled mechanism is used or supported for automatic voltage adjustment.

Sliding Contact Replaceable

Indicates that the moving electrical contact or brush used for variable-voltage adjustment is replaceable.

Adjustment Rotation Angle°

Mechanical angular travel associated with the full usable voltage adjustment range.

Adjustment Position Indicator Present

Indicates that the product provides a scale, pointer, dial or other indication of the voltage adjustment position.

Mechanical End Stops Present

Indicates that mechanical end stops limit travel of the voltage adjustment mechanism.

Standards and Compliance28
IEC 61558-1 Compliant

Compliance with applicable IEC 61558-1 general safety requirements for transformers, reactors, power supply units and combinations thereof.

EN IEC 61558-1 Compliant

Compliance with the applicable European adoption of IEC 61558-1.

UL 5085-1 Compliant

Compliance with UL 5085-1 general requirements applicable to low-voltage transformers.

UL 5085-2 Compliant

Compliance with UL 5085-2 requirements applicable to general-purpose low-voltage transformers and autotransformers.

UL 5085-3 Compliant

Compliance with UL 5085-3 requirements applicable to Class 2 and Class 3 low-voltage transformers.

IEC 61558-2-13 Compliant

Compliance with IEC 61558-2-13 requirements applicable to autotransformers and power supply units incorporating autotransformers.

EN IEC 61558-2-13 Compliant

Compliance with the applicable European adoption of IEC 61558-2-13.

Conformity Regions

Regions or markets for which the manufacturer declares regulatory or certification compliance of the product.

Certification and Conformity Marks

Certification, market-approval, or conformity marks applicable to the product.

Primary Product Standard

Primary normative document or standard according to which the manufacturer classifies or assesses the product.

Additional Standards

Additional normative documents and standards declared by the manufacturer as applicable to the product.

Declaration of Conformity Available

Indicates whether an official declaration of conformity is available for the product.

Certificate Available

Indicates whether a certificate relating to the declared certification or conformity of the product is available.

Certificate Number

Identification number of the certificate relating to the product or its certified version.

Certification Body

Name of the organization that issued the certificate or performed the relevant conformity assessment.

Third-Party Tested

Indicates whether the product was tested by an organization independent of the manufacturer.

CE Marked

Indicates whether the CE marking is applied to the product where applicable.

UKCA Marked

Indicates whether the UKCA marking is applied to the product where applicable.

EAC Marked

Indicates whether the EAC marking is applied to the product where applicable.

UL Listed

Indicates whether the product has a declared UL Listed certification or recognition status.

UL Recognized

Indicates whether the product has a declared UL Recognized certification or recognition status.

cULus Marked

Indicates whether the cULus mark is applied to the product where applicable.

CSA Certified

Indicates whether the product has a declared CSA certification or recognition status.

TÜV Certified

Indicates whether the product has a declared TÜV certification or recognition status.

VDE Certified

Indicates whether the product has a declared VDE certification or recognition status.

RoHS Compliant

Indicates whether product compliance with applicable RoHS restrictions on hazardous substances has been declared.

REACH Compliant

Indicates whether the manufacturer declares compliance of the product with applicable REACH Regulation requirements.

WEEE Applicable

Indicates whether the product falls within the scope of WEEE requirements for waste electrical and electronic equipment.

Logistics10
Net Weightkg

Mass of the product itself, excluding transport packaging, additional accessories, and external equipment.

Gross Weightkg

Mass of the product together with its individual packaging and the accessories included in it.

Package Widthmm

External horizontal dimension of the product's individual package.

Package Heightmm

External vertical dimension of the product's individual package.

Package Depthmm

External depth dimension of the product's individual package.

Packaging Type

Design type of the product's individual or transport packaging.

Units per Package

Number of individual products contained in one packaging unit at the specified level.

Country of Origin

Country of origin of the goods declared for customs or commercial purposes.

HS Code

Commodity code under the international Harmonized Commodity Description and Coding System.

Combined Nomenclature Code

Commodity code under the Combined Nomenclature of the European Union.