Device description

Drive Line Module

Input power module of a modular drive system converting mains power into common DC-bus voltage.

A drive line module supplies the DC link for one or more power modules in a modular drive system.

Depending on topology it may be a passive rectifier or an active front end with mains-current control and regenerative capability. Regenerative versions can return braking energy from the DC link to the supply.

Key parameters include input voltage, rated and peak power, topology, maximum regenerative power, and common DC-bus characteristics.

Selection considers the supply system, total drive power, regeneration requirements, harmonics, EMC, and compatibility with the other modules.

Components in this subcategory

Line modules, rectifier modules, and active-front-end modules for modular drive systems.

Available parameters

Drive Line Module

47 parameters
General3
Product Series

Commercial or technical designation of a manufacturer's product family sharing a common design and compatible characteristics.

Application

Range of tasks and systems for which the manufacturer recommends the component.

Intended Use

Primary function of the device and its intended use as defined by its design and the manufacturer's documentation.

Dimensions6
Widthmm

External horizontal dimension of the product between its outermost lateral points.

Heightmm

External vertical dimension of the product from its lowest to its highest point.

Depthmm

External distance between the foremost and rearmost surfaces of the product.

Lengthmm

External linear dimension of the product along its longitudinal direction or principal length axis.

Diametermm

Transverse dimension of a product or its circular element measured through the centre between opposite points of the circumference.

Net Weightkg

Mass of the product itself, excluding transport packaging, additional accessories, and external equipment.

Mounting and Installation8
Mounting Method

Method used to mechanically secure the product to a support, surface, or load-bearing structure.

Mounting Type

Installation arrangement permitted by the product design, such as wall-mounted, flush-mounted, floor-mounted, or another specified mounting type.

Orientation

Permissible spatial orientation of the component during installation and operation.

DIN Rail Mounting Supported

Indicates whether the design provides for mounting equipment on a DIN rail.

Number of Mounting Holes

Number of holes provided in the product for mechanical fixing.

Mounting Hole Diametermm

Diameter of the hole provided for a fixing element used when mounting the product.

Horizontal Mounting Hole Spacingmm

Distance between the centres of mounting holes in the horizontal direction.

Vertical Mounting Hole Spacingmm

Distance between the centres of mounting holes in the vertical direction.

Electrical Parameters10
Rated VoltageV

Voltage value assigned to the product by the manufacturer for specified application conditions and characteristics.

Line Module Topology

Mains-side conversion topology of the drive line module.

Rated CurrentA

Current assigned to the product by the manufacturer for the declared operating and thermal conditions.

Regenerative Operation Supported

Indicates that regenerated motor energy can be returned toward the electrical supply or common DC system rather than only dissipated as heat.

Rated PowerW

Rated active electrical power of the product declared by the manufacturer for specified operating conditions.

Maximum Regenerative PowerW

Maximum manufacturer-declared power that can be returned to the supply or common DC link.

Rated FrequencyHz

AC frequency assigned to the product for normal operating conditions.

Minimum DC Bus VoltageV

Minimum DC-bus voltage within the manufacturer-declared operating range.

Maximum DC Bus VoltageV

Maximum DC-bus voltage within the manufacturer-declared operating range.

Power ConsumptionW

Electrical power consumed by the product itself in the declared normal operating mode.

Environmental Conditions10
IP Rating

Degree of enclosure protection against access to hazardous parts and ingress of solid objects and water, designated by the IP code.

IK Rating

Class of enclosure resistance to external mechanical impacts designated by the IK code.

Minimum Operating Temperature°C

Minimum ambient temperature at which normal operation of the product is permitted.

Maximum Operating Temperature°C

Maximum ambient temperature at which normal operation of the product is permitted.

Minimum Storage Temperature°C

Minimum ambient temperature permitted during storage of the product while not in operation.

Maximum Storage Temperature°C

Maximum ambient temperature permitted during storage of the product while not in operation.

Minimum Relative Humidity%

Minimum relative air humidity permitted for the declared operating or test condition.

Maximum Relative Humidity%

Maximum relative air humidity permitted for the declared operating or test condition.

Vibration Resistant

Indicates whether the product's resistance to vibration has been verified under the declared conditions.

Mechanical Shock Resistant

Indicates whether the product's resistance to short-duration mechanical shocks has been verified.

Special Features4
Communication Supported

Indicates whether the product supports digital data exchange with external devices or systems.

Communication Protocols

List of supported digital data communication protocols.

Communication Interfaces

List of supported physical or logical digital communication interfaces.

Ethernet Port Count

Number of integrated physical Ethernet communication ports.

Standards and Compliance6
CE Marked

Indicates whether the CE marking is applied to the product where applicable.

RoHS Compliant

Indicates whether product compliance with applicable RoHS restrictions on hazardous substances has been declared.

IEC 60529 Compliant

Indicates whether the manufacturer declares product compliance with IEC 60529.

IEC 60068 Tested

Indicates whether the product has been tested according to applicable methods of the IEC 60068 series.

IEC 61800-3 Compliant

Compliance with applicable IEC 61800-3 EMC requirements for adjustable-speed electrical power drive systems.

IEC 61800-5-1 Compliant

Compliance with applicable IEC 61800-5-1 safety requirements for adjustable-speed electrical power drive systems.