TRASA3 Knowledge Base

Electrical Component Parameter Reference

An open technical reference for electrical component types, their applications, and selection parameters.

This material is also available in PL and RU.

Device description

EV Charging Energy Meter

Electrical meter for measuring energy, power, and other parameters of an EV charging point or charging session.

An EV energy meter measures the electrical energy consumed by an electric vehicle during charging.

It may be integrated into EVSE or installed as a separate instrument in the supply circuit.

Depending on the model, measurements may include voltage, current, power, energy, power factor, and other network parameters.

For commercial billing, accuracy class, certification, MID execution, or other market-specific requirements are important.

The meter may transmit measured values to EVSE, a controller, EMS, or backend through digital interfaces.

Selection criteria include number of phases, current-measurement arrangement, accuracy, communication interface, tariff requirements, and charging-system integration.

Components in this subcategory

Energy meters for EVSE, wallboxes, AC/DC charging, and commercial charging-session billing.

Available parameters

EV Charging Energy Meter

291 parameters
Dimensions4
Widthmm

External horizontal dimension of the product between its outermost lateral points.

Heightmm

External vertical dimension of the product from its lowest to its highest point.

Depthmm

External distance between the foremost and rearmost surfaces of the product.

Net Weightkg

Mass of the product itself, excluding transport packaging, additional accessories, and external equipment.

Materials and Finish2
Color

Primary visually perceived colour of the product's external surface.

Material

Primary material from which the product is manufactured.

Mounting and Installation3
Orientation

Permissible spatial orientation of the component during installation and operation.

Mounting Type

Installation arrangement permitted by the product design, such as wall-mounted, flush-mounted, floor-mounted, or another specified mounting type.

Mounting Method

Method used to mechanically secure the product to a support, surface, or load-bearing structure.

Electrical Parameters130
Rated VoltageV

Voltage value assigned to the product by the manufacturer for specified application conditions and characteristics.

Rated FrequencyHz

AC frequency assigned to the product for normal operating conditions.

Number of Phases

Number of phases of the electrical system for which the product is designed to be connected or used.

Rated CurrentA

Current assigned to the product by the manufacturer for the declared operating and thermal conditions.

Maximum Incoming Conductor Cross-Sectionmm²

Maximum nominal conductor cross-section permitted at the product's incoming connection.

Maximum Outgoing Conductor Cross-Sectionmm²

Maximum nominal conductor cross-section permitted at the product's outgoing connection.

Rated Insulation VoltageV

Voltage with reference to which the product's insulation clearances and dielectric properties are specified.

Rated Impulse Withstand VoltagekV

Peak value of an impulse voltage of specified waveform that the product insulation must withstand without breakdown.

Minimum Incoming Conductor Cross-Sectionmm²

Minimum conductor cross-section permitted for connection to the incoming terminal of the main power circuit.

Minimum Outgoing Conductor Cross-Sectionmm²

Minimum conductor cross-section permitted for connection to the outgoing terminal of the main power circuit.

Voltage Measurement Supported

Indicates whether the product can measure and provide electrical voltage values.

Current Measurement Supported

Indicates whether the product can measure and provide electrical current values.

Frequency Measurement Supported

Indicates whether the product can measure and provide electrical network frequency values.

Energy Measurement Supported

Indicates whether measurement or cumulative metering of electrical energy is supported.

Current Unbalance Measurement Supported

Indicates whether current unbalance measurement or calculation is supported.

Voltage Unbalance Measurement Supported

Indicates whether voltage unbalance measurement or calculation is supported.

Incoming Connection Point Count

Number of electrical connection points intended for incoming or supply-side connections.

Outgoing Connection Point Count

Number of electrical connection points intended for outgoing or load-side connections.

Incoming Connection Type

Electrical connection technologies supported at the incoming or supply-side connection points of the product.

Outgoing Connection Type

Electrical connection technologies supported at the outgoing or load-side connection points of the product.

Incoming Terminal Tightening TorqueNm

Manufacturer-declared tightening torque for an incoming or supply terminal.

Outgoing Terminal Tightening TorqueNm

Manufacturer-declared tightening torque for an outgoing or load-side terminal.

Configurable Current Transformer Ratio

Indicates that the current transformer ratio used for measurement scaling can be configured in the device.

Minimum Current Transformer Primary Current SettingA

Minimum configurable primary current value used for current transformer scaling.

Maximum Current Transformer Primary Current SettingA

Maximum configurable primary current value used for current transformer scaling.

Supported Current Transformer Secondary Currents

Standard secondary current ratings of external current transformers supported by the measuring input.

Active Power Measurement Supported

Indicates that active electrical power is measured or calculated by the device.

Reactive Power Measurement Supported

Indicates that reactive electrical power is measured or calculated by the device.

Apparent Power Measurement Supported

Indicates that apparent electrical power is measured or calculated by the device.

Power Factor Measurement Supported

Indicates that the electrical power factor is measured or calculated by the device.

Monitored Voltage Current Type

Current type of the monitored voltage measuring circuit: AC, DC or AC/DC.

Minimum Monitored VoltageV

Lower limit of the manufacturer-declared voltage measuring range.

Maximum Monitored VoltageV

Upper limit of the manufacturer-declared voltage measuring range.

Voltage Measurement Accuracy%

Manufacturer-declared accuracy of voltage measurement where expressed as a single percentage value.

Minimum Monitored FrequencyHz

Lower limit of the manufacturer-declared frequency measurement range.

Maximum Monitored FrequencyHz

Upper limit of the manufacturer-declared frequency measurement range.

Frequency Measurement AccuracyHz

Manufacturer-declared absolute accuracy of frequency measurement.

Minimum Monitored CurrentA

Lower limit of the manufacturer-declared current measuring range.

Maximum Monitored CurrentA

Upper limit of the manufacturer-declared current measuring range.

Current Measurement Accuracy%

Manufacturer-declared relative accuracy of current measurement where expressed as a percentage.

Minimum Current Transformer Ratio

Minimum configurable primary-to-secondary current transformer ratio.

Maximum Current Transformer Ratio

Maximum configurable primary-to-secondary current transformer ratio.

Minimum Active Power MeasurementW

Lower limit of the manufacturer-declared active-power measuring range.

Maximum Active Power MeasurementW

Upper limit of the manufacturer-declared active-power measuring range.

Active Power Measurement Accuracy%

Manufacturer-declared relative accuracy of active-power measurement.

Minimum Reactive Power Measurementvar

Lower limit of the manufacturer-declared reactive-power measuring range.

Maximum Reactive Power Measurementvar

Upper limit of the manufacturer-declared reactive-power measuring range.

Reactive Power Measurement Accuracy%

Manufacturer-declared relative accuracy of reactive-power measurement.

Minimum Apparent Power MeasurementVA

Lower limit of the manufacturer-declared apparent-power measuring range.

Maximum Apparent Power MeasurementVA

Upper limit of the manufacturer-declared apparent-power measuring range.

Apparent Power Measurement Accuracy%

Manufacturer-declared relative accuracy of apparent-power measurement.

Minimum Power Factor Measurement

Lower limit of the manufacturer-declared power-factor measuring range.

Maximum Power Factor Measurement

Upper limit of the manufacturer-declared power-factor measuring range.

Power Factor Measurement Accuracy

Manufacturer-declared absolute accuracy of power-factor measurement expressed as a cos φ value difference.

Metering Connection Type

Overall electrical measurement connection topology of the device, distinguishing direct measurement and operation through external current, voltage, shunt, Rogowski or sensor interfaces.

Voltage Measurement Connection Method

Supported methods for connecting the voltage measuring circuit, such as direct connection or connection through an external voltage transformer.

Voltage Transformer Input Supported

Indicates that the measuring device supports voltage measurement through an external voltage transformer.

Configurable Voltage Transformer Ratio

Indicates that the voltage transformer ratio used for measurement scaling can be configured in the device.

Minimum Voltage Transformer Primary Voltage SettingV

Minimum configurable primary voltage value used for voltage-transformer measurement scaling.

Maximum Voltage Transformer Primary Voltage SettingV

Maximum configurable primary voltage value used for voltage-transformer measurement scaling.

Supported Voltage Transformer Secondary Voltages

Standard secondary voltage ratings of external voltage transformers supported by the measuring input.

Bidirectional Energy Measurement Supported

Indicates separate measurement or registration of energy flowing in both import and export directions.

Four-Quadrant Measurement Supported

Indicates support for four-quadrant measurement of active and reactive power or energy, distinguishing direction and reactive quadrant where applicable.

Per-Phase Measurement Supported

Indicates that measured electrical quantities are available separately for individual phases.

Phase-to-Phase Voltage Measurement Supported

Indicates that phase-to-phase voltage values can be measured and made available by the device.

Phase-to-Neutral Voltage Measurement Supported

Indicates that phase-to-neutral voltage values can be measured and made available by the device.

Neutral Current Measurement Supported

Indicates that current in the neutral conductor can be measured independently.

Total System Measurement Supported

Indicates that aggregate or total system values are calculated in addition to individual phase measurements.

Active Energy Measurement Supported

Indicates that the device measures or accumulates active electrical energy.

Reactive Energy Measurement Supported

Indicates that the device measures or accumulates reactive electrical energy.

Apparent Energy Measurement Supported

Indicates that the device measures or accumulates apparent electrical energy.

Imported Energy Measurement Supported

Indicates separate measurement or accumulation of imported energy.

Exported Energy Measurement Supported

Indicates separate measurement or accumulation of exported energy.

Net Energy Measurement Supported

Indicates calculation or accumulation of net energy resulting from import and export energy flow.

Supported Reactive Energy Quadrants

Reactive-energy quadrants that can be separately measured or registered.

Active Energy Accuracy Class

Manufacturer-declared accuracy class for active electrical energy measurement.

Reactive Energy Accuracy Class

Manufacturer-declared accuracy class for reactive electrical energy measurement.

Meter Reference CurrentA

Reference current Iref declared for an electricity meter where applicable.

Meter Basic CurrentA

Basic current Ib declared for a direct-connected electricity meter where applicable.

Meter Minimum CurrentA

Minimum current Imin associated with the declared metrological performance of the meter.

Meter Transition CurrentA

Transition current Itr associated with the declared metrological accuracy region of the meter.

Meter Starting CurrentA

Minimum current at which the electricity meter starts and continues energy registration under declared conditions.

Meter Maximum CurrentA

Maximum meter current Imax associated with the declared metrological current range.

Multi-Tariff Metering Supported

Indicates that energy values can be accumulated separately in multiple tariff registers.

Tariff Count

Maximum number of independent energy tariffs supported by the meter.

Tariff Switching Methods

Methods supported for selecting or switching active tariff registers.

Total Energy Register Supported

Indicates the presence of a cumulative total-energy register.

Partial Energy Register Supported

Indicates the presence of one or more partial or subtotal energy registers.

Partial Energy Register Resettable

Indicates that a partial energy register can be reset without clearing the legally relevant total-energy register.

Maximum Demand Register Supported

Indicates storage of the maximum calculated demand value.

Configurable Demand Interval

Indicates that the demand calculation interval can be configured.

Minimum Demand Intervals

Minimum configurable interval used for demand calculation.

Maximum Demand Intervals

Maximum configurable interval used for demand calculation.

Load Profile Supported

Indicates that time-series load or energy profile data can be recorded internally.

Minimum Load Profile Intervals

Minimum configurable interval between stored load-profile records.

Maximum Load Profile Intervals

Maximum configurable interval between stored load-profile records.

Load Profile Capacityrecords

Maximum number of load-profile records retained internally.

Energy Pulse Output Supported

Indicates that accumulated energy can be represented by an electrical pulse output.

Active Energy Pulse Output Constantimp/kWh

Number of output pulses corresponding to one kilowatt-hour of active energy.

Reactive Energy Pulse Output Constantimp/kvarh

Number of output pulses corresponding to one kilovar-hour of reactive energy.

Pulse Output Widthms

Duration of a single energy pulse generated by the pulse output.

Pulse Output Type

Electrical implementation of the pulse output used for metering or counting.

Optical Metrology LED Present

Indicates the presence of an optical metrology LED generating pulses proportional to measured energy.

Optical Metrology LED Constantimp/kWh

Number of optical metrology LED pulses corresponding to one kilowatt-hour.

Phase Angle Measurement Supported

Indicates that the phase angle between relevant voltage and/or current quantities can be measured or calculated.

Voltage THD Measurement Supported

Indicates measurement or calculation of total harmonic distortion of voltage.

Current THD Measurement Supported

Indicates measurement or calculation of total harmonic distortion of current.

Removable Terminal Blocks

Indicates that one or more terminal blocks can be removed from the device body for wiring or service.

Pluggable Terminal Blocks

Indicates that one or more electrical terminal blocks use a pluggable disconnectable connection system.

Terminal Pitchmm

Centre-to-centre pitch between adjacent electrical terminals in the relevant terminal row.

Terminal Marking Present

Indicates that electrical connection terminals are individually identified by manufacturer-applied markings.

Terminal Access Direction

Physical directions from which conductors or tools access the electrical connection terminals.

Minimum Terminal Conductor Cross-Sectionmm²

Minimum conductor cross-section accepted by the relevant general device terminal connection.

Maximum Terminal Conductor Cross-Sectionmm²

Maximum conductor cross-section accepted by the relevant general device terminal connection.

Sealable Terminal Cover

Indicates that the terminal cover can be sealed or plombed against unauthorized access.

CT Polarity Error Detection Supported

Indicates that incorrect current-transformer polarity or reversed current measurement direction can be detected.

Phase Assignment Error Detection Supported

Indicates that an incorrect relationship between voltage and current phase channels can be detected.

Per-Charging-Point Metering Supported

Indicates that electrical quantities or energy can be measured independently for individual charging points.

Charging Session Metering Supported

Indicates that energy transferred during an individual EV charging session can be measured or accumulated separately.

Charging Session Start Meter Value Supported

Indicates that a meter reading corresponding to the beginning of a charging transaction or session can be recorded or reported.

Charging Session Stop Meter Value Supported

Indicates that a meter reading corresponding to the end of a charging transaction or session can be recorded or reported.

Meter Value Reporting Supported

Indicates that electrical meter values can be periodically transmitted or reported to another device or backend system.

Minimum Meter Value Reporting Intervals

Minimum configurable interval between periodic meter-value reports.

Maximum Meter Value Reporting Intervals

Maximum configurable interval between periodic meter-value reports.

Signed Meter Values Supported

Indicates that metering data can be cryptographically signed or otherwise protected for authenticity and integrity verification.

Charging Session Log Supported

Indicates that historical records of EV charging sessions can be retained locally or in an integrated logging subsystem.

Charging Session Log Capacity

Maximum number of charging-session records that can be retained by the product where manufacturer-declared.

Charging Session Counter Supported

Indicates that the cumulative number of charging sessions can be retained as an operating statistic.

Cumulative Charging Time Counter Supported

Indicates that cumulative active EV charging time can be retained as an operating statistic.

Cumulative Charged Energy Counter Supported

Indicates that cumulative energy transferred toward connected EVs can be retained as a lifetime operating statistic.

Protection and Safety6
IP Rating

Degree of enclosure protection against access to hazardous parts and ingress of solid objects and water, designated by the IP code.

IK Rating

Class of enclosure resistance to external mechanical impacts designated by the IK code.

Reverse Energy Detection Supported

Indicates detection or signalling of reverse energy flow.

Non-Volatile Energy Register Memory

Indicates that accumulated energy registers are retained without normal supply voltage.

Energy Register Retention During Power Failure

Indicates that energy register values are preserved across supply interruptions.

Anti-Tamper Event Detection Supported

Indicates that the meter can detect and register manufacturer-defined tamper or manipulation events.

Environmental Conditions6
Minimum Operating Temperature°C

Minimum ambient temperature at which normal operation of the product is permitted.

Maximum Operating Temperature°C

Maximum ambient temperature at which normal operation of the product is permitted.

Minimum Storage Temperature°C

Minimum ambient temperature permitted during storage of the product while not in operation.

Maximum Storage Temperature°C

Maximum ambient temperature permitted during storage of the product while not in operation.

Maximum Relative Humidity%

Maximum relative air humidity permitted for the declared operating or test condition.

Maximum Installation Altitudem

Maximum altitude above sea level at which the product may be installed without exceeding the declared conditions.

Included Equipment11
Display Present

Indicates whether the product has an integrated local display.

Display Type

Technology or construction type of the product's integrated display.

Display Backlight

Indicates whether the integrated display has a backlight.

Status LED Count

Number of integrated LEDs used to indicate product status or operating modes.

Display Diagonalmm

Physical diagonal dimension of the integrated display viewing area.

Display Page Count

Number of predefined or configurable local display pages available for measured values or device information.

Display Auto-Scroll Supported

Indicates that the device can automatically cycle through display pages or measured values.

Display Unit Indication Supported

Indicates that the measurement unit associated with a displayed value is shown locally.

Display Phase Identification Supported

Indicates that local measured-value presentation identifies the associated phase or conductor.

Local Configuration Lock Supported

Indicates that local configuration access can be intentionally restricted against unauthorized changes.

Local Configuration Lock Methods

Methods supported for restricting access to local device configuration.

Special Features54
Event Log Supported

Indicates whether the product can store an internal event log.

Event Log Capacityevents

Maximum number of event records that can be stored in the product's internal log.

Real-Time Clock Present

Indicates whether an integrated real-time clock is provided for timekeeping, event time-stamping, or time-based functions.

Communication Protocols

List of supported digital data communication protocols.

Communication Interfaces

List of supported physical or logical digital communication interfaces.

Integrated Web Server

Indicates whether an integrated web server or web interface is provided for access to product functions.

Remote Configuration Supported

Indicates whether specified product settings can be read or changed remotely through a supported communication interface.

Remote Diagnostics Supported

Indicates whether diagnostic information, status data, or fault information can be obtained remotely.

Firmware Updatable

Indicates that device firmware can be updated by a manufacturer-supported procedure.

Ethernet Port Count

Number of integrated physical Ethernet communication ports.

Measurement Data Logging Supported

Indicates that measured electrical values can be stored internally as historical measurement records.

Measurement Data Log Capacityrecords

Maximum number of historical measurement records retained internally.

Configurable Measurement Logging Interval

Indicates that the interval between periodic measurement records can be configured.

Minimum Measurement Logging Intervals

Minimum configurable interval between periodically stored measurement records.

Maximum Measurement Logging Intervals

Maximum configurable interval between periodically stored measurement records.

Measurement Data Logging Trigger Modes

Supported conditions or commands that initiate storage of measurement records.

Measurement Data Memory Capacitybytes

Manufacturer-declared internal non-volatile memory capacity available for measurement history or logging.

Historical Data Export Supported

Indicates that stored measurement or event history can be exported from the device.

Measurement Data Export Formats

File or interchange formats supported for exporting stored measurement data.

Alarm Log Supported

Indicates that alarm occurrences are stored in a dedicated alarm history or log.

Alarm Log Capacityevents

Maximum number of alarm records retained in the dedicated alarm history.

Alarm Acknowledgement Supported

Indicates that active or stored alarms can be explicitly acknowledged by the user or supervisory system.

Maximum Demand Reset Supported

Indicates that the stored maximum demand register can be reset using a manufacturer-supported procedure.

Min/Max Value Reset Supported

Indicates that stored minimum and maximum measured values can be reset.

Supported Serial Baud Rates

Supported serial communication baud rates for interfaces such as RS-232, RS-422, RS-485 or equivalent serial buses.

Supported Serial Data Bits

Supported data-word lengths for serial communication.

Supported Serial Parity Modes

Parity modes supported by the serial communication interface.

Supported Serial Stop Bits

Supported number of stop bits in serial communication frames.

Configurable Serial Device Address

Indicates that the logical device or slave address used by a serial communication protocol can be configured.

Minimum Serial Device Address

Minimum configurable logical address on a supported serial communication network.

Maximum Serial Device Address

Maximum configurable logical address on a supported serial communication network.

Supported Ethernet Link Speeds

Supported nominal Ethernet physical-layer link speeds.

Ethernet IP Address Assignment Methods

Supported methods for assigning network-layer addresses to the Ethernet interface.

IPv6 Supported

Indicates support for Internet Protocol version 6 communication.

Wireless Communication Supported

Indicates that one or more integrated or optional wireless communication technologies are supported.

Wireless Communication Technologies

Wireless communication technologies supported by the product.

Supported Cellular Technologies

Cellular network technologies supported by the integrated or optional modem.

Supported SIM Form Factors

Physical or embedded SIM formats supported by a cellular communication module.

External Communication Antenna Supported

Indicates that an external antenna can be connected for wireless or cellular data communication.

Wireless Signal Strength Reporting Supported

Indicates that wireless or cellular signal-strength information is available locally or through communication.

Automatic Data Push Supported

Indicates that measured or logged data can be transmitted automatically without an explicit polling request.

Cloud Connectivity Supported

Indicates manufacturer-supported communication with a cloud or remote Internet service.

API Access Supported

Indicates that measurement, status or configuration data can be accessed through a documented application programming interface.

Supported API Types

Application programming interface types supported by the product or its integrated communication service.

Remote Firmware Update Supported

Indicates that firmware can be updated through a supported local or remote data communication interface.

Communication Watchdog Supported

Indicates that loss or inactivity of a communication link can be detected by an internal communication watchdog.

User Authentication Supported

Indicates that access to network, web, API or remote configuration functions can require authenticated user credentials.

Encrypted Communication Supported

Indicates support for encrypted data communication through one or more manufacturer-supported communication services.

Supported TLS Versions

Transport Layer Security protocol versions supported for protected network communication.

Role-Based Access Control Supported

Indicates that user permissions can be differentiated by user role or authorization level.

Security Event Logging Supported

Indicates that security-relevant events such as authentication failures or configuration access can be recorded.

Secure Boot Supported

Indicates that the device verifies the integrity or authenticity of executable firmware during startup.

Signed Firmware Update Supported

Indicates that firmware update packages are cryptographically authenticated before installation.

Communication Failure Alarm Supported

Indicates that loss of an expected communication connection can generate a local or remote alarm or diagnostic condition.

Standards and Compliance63
CE Marked

Indicates whether the CE marking is applied to the product where applicable.

Legal Metrology Applicable

Indicates that the product is intended for a measurement application subject to legal metrology requirements.

Legal-for-Trade Approved

Indicates manufacturer-declared approval for legally regulated or commercial measurement use in at least one applicable jurisdiction.

Revenue Metering Suitable

Indicates suitability for revenue or billing energy metering where the manufacturer explicitly declares such use.

MID 2014/32/EU Compliant

Compliance with Directive 2014/32/EU on measuring instruments where applicable.

MID MI-003 Applicable

Indicates that the product falls within the MID MI-003 category for active electrical energy meters.

MID Conformity Assessment Procedures

MID conformity assessment procedures under which the active electrical energy meter may be assessed.

Metrological Marking Present

Indicates that legally required metrological marking is applied to the product where applicable.

Supplementary Metrology Marking Present

Indicates presence of the supplementary metrology marking required by the applicable European measuring-instrument conformity scheme.

Notified Body Number

Identification number of the notified body associated with the applicable conformity assessment or metrological marking.

Metrological Type Approval Available

Indicates that a type-approval or equivalent legal-metrology approval exists for the product.

Metrological Type Approval Number

Manufacturer- or authority-declared identifier of the applicable legal-metrology type approval.

Metrological Seal Required

Indicates that metrological sealing is required to protect legally relevant settings or measurement access.

Metrological Sealing Supported

Indicates that dedicated provisions exist for applying a metrological seal.

Factory Metrologically Sealed

Indicates that the catalog product is normally supplied with manufacturer-applied metrological sealing where applicable.

Calibration Supported

Indicates that the measuring function can be calibrated using a manufacturer-defined procedure.

Factory Calibrated

Indicates that the product is calibrated by the manufacturer before delivery.

Calibration Certificate Available

Indicates that a calibration certificate can be supplied for the product.

Recommended Calibration Intervalmonths

Manufacturer-recommended interval between periodic calibrations, where such an interval is specified.

Field Calibration Supported

Indicates that calibration can be performed in the installed location without factory return.

User Calibration Supported

Indicates that an authorized user can execute a manufacturer-supported calibration procedure.

Zero Calibration Supported

Indicates support for adjustment or calibration of measurement zero offset.

Span Calibration Supported

Indicates support for gain or span calibration using a reference measurement value.

Calibration Point Count

Number of calibration points supported by the manufacturer-defined calibration procedure.

Calibration Access Protected

Indicates that access to calibration parameters or procedures is protected against unauthorized changes.

Measurement Accuracy Verification Supported

Indicates that the manufacturer provides a defined procedure or test facility for verifying measurement accuracy.

Metrological Self-Test Supported

Indicates an internal self-test covering legally or technically relevant measurement functions.

Metrological Event Log Supported

Indicates storage of events relevant to metrological integrity, legal settings or protected measurement functions.

Metrological Parameter Change Log Supported

Indicates that changes to legally or metrologically relevant configuration parameters are recorded.

Metrological Parameters Write Protected

Indicates that metrologically relevant parameters are protected against unauthorized modification.

Billing Registers Write Protected

Indicates that legally or commercially relevant accumulated billing registers cannot be arbitrarily modified.

IEC 62052-11 Compliant

Compliance with IEC 62052-11 general requirements, tests and test conditions for electricity metering equipment.

EN IEC 62052-11 Compliant

Compliance with the European adoption of IEC 62052-11 for electricity metering equipment.

IEC 62052-31 Compliant

Compliance with IEC 62052-31 product safety requirements for electrical energy metering equipment.

EN IEC 62052-31 Compliant

Compliance with the European adoption of IEC 62052-31 metering-equipment safety requirements.

IEC 62053-21 Compliant

Compliance with IEC 62053-21 requirements applicable to static meters for active electrical energy.

EN IEC 62053-21 Compliant

Compliance with the European adoption of IEC 62053-21 for static active-energy meters.

IEC 62053-22 Compliant

Compliance with IEC 62053-22 requirements applicable to higher-accuracy static active-energy meters.

EN IEC 62053-22 Compliant

Compliance with the European adoption of IEC 62053-22.

IEC 62053-23 Compliant

Compliance with IEC 62053-23 requirements applicable to static reactive-energy meters.

EN IEC 62053-23 Compliant

Compliance with the European adoption of IEC 62053-23.

IEC 62053-24 Compliant

Compliance with IEC 62053-24 requirements applicable to static reactive-energy measurement at fundamental frequency.

EN IEC 62053-24 Compliant

Compliance with the European adoption of IEC 62053-24.

IEC 62053-31 Compliant

Compliance with IEC 62053-31 requirements applicable to pulse-output devices for electrical energy meters.

EN IEC 62053-31 Compliant

Compliance with the European adoption of IEC 62053-31 for meter pulse outputs.

IEC 62056-21 Compliant

Compliance with IEC 62056-21 requirements for local data exchange with electricity meters.

EN IEC 62056-21 Compliant

Compliance with the European adoption of IEC 62056-21.

EN 50470-1 Compliant

Compliance with EN 50470-1 requirements applicable to electricity metering equipment.

EN 50470-3 Compliant

Compliance with EN 50470-3 requirements applicable to static active-energy meters.

OIML R 46 Compliant

Compliance with OIML R 46 recommendations applicable to active electrical energy meters.

IEC 61557-12 Compliant

Compliance with IEC 61557-12 requirements for power metering and monitoring devices.

EN IEC 61557-12 Compliant

Compliance with the European adoption of IEC 61557-12 for power metering and monitoring devices.

IEC 61000-4-30 Compliant

Compliance with IEC 61000-4-30 power-quality measurement methods.

EN 61000-4-30 Compliant

Compliance with the European adoption of IEC 61000-4-30 power-quality measurement methods.

IEC 61000-4-7 Compliant

Compliance with IEC 61000-4-7 requirements for harmonics and interharmonics measurement and instrumentation.

EN 61000-4-7 Compliant

Compliance with the European adoption of IEC 61000-4-7.

IEC 61000-4-15 Compliant

Compliance with IEC 61000-4-15 functional and design requirements for flickermeters.

EN 61000-4-15 Compliant

Compliance with the European adoption of IEC 61000-4-15.

IEC 62586-1 Compliant

Compliance with IEC 62586-1 product and performance requirements for power-quality instruments.

IEC 62586-2 Compliant

Compliance with IEC 62586-2 functional tests and uncertainty requirements for power-quality instruments.

Low Voltage Directive 2014/35/EU Compliant

Compliance with Directive 2014/35/EU where applicable to the product.

EMC Directive 2014/30/EU Compliant

Compliance with Directive 2014/30/EU on electromagnetic compatibility where applicable.

Radio Equipment Directive 2014/53/EU Compliant

Compliance with Directive 2014/53/EU where the product constitutes radio equipment.

Logistics12
Gross Weightkg

Mass of the product together with its individual packaging and the accessories included in it.

Package Widthmm

External horizontal dimension of the product's individual package.

Package Heightmm

External vertical dimension of the product's individual package.

Package Depthmm

External depth dimension of the product's individual package.

Package Volumem³

Calculated or declared external volume of the product's individual package.

Packaging Type

Design type of the product's individual or transport packaging.

Packaging Material

Primary materials from which the product packaging is made.

Package Tare Weightkg

Mass of the empty packaging without the product and its accessories.

Units per Package

Number of individual products contained in one packaging unit at the specified level.

Recyclable Packaging

Indicates whether the packaging used is declared recyclable as secondary raw material.

Reusable Packaging

Indicates whether the packaging is designed for reuse without changing its primary purpose.

Returnable Packaging

Indicates whether the packaging is intended to be returned to the supplier, manufacturer, or another participant in the logistics chain.