EV Charger Pedestal
Floor-mounted or outdoor support structure for installation of one or more EV charging stations.
An EV charger pedestal is used to install a wallbox or other EVSE where wall mounting is not possible or desirable.
The structure may provide one or more mounting positions, including back-to-back installation of chargers.
Depending on the design, the pedestal may be installed on a foundation, anchor plate, or by burial in the ground.
Supply and communication cables may be routed internally through the structure with underground entry.
Selection criteria include compatibility with the specific charger, number of positions, base-plate dimensions, foundation requirements, material, protective coating, and cable-entry method.
Pedestals, columns, and floor supports for EV wallboxes and charging stations.
EV Charger Pedestal
Dimensions4
External horizontal dimension of the product between its outermost lateral points.
External vertical dimension of the product from its lowest to its highest point.
External distance between the foremost and rearmost surfaces of the product.
Mass of the product itself, excluding transport packaging, additional accessories, and external equipment.
Materials and Finish9
Primary visually perceived colour of the product's external surface.
Designation of the product's primary surface colour according to the RAL colour system.
Type of final surface finish of the product determining its appearance and service properties.
Technological surface treatment applied to modify its protective, mechanical, or decorative properties.
Type of protective, functional, or decorative coating applied to the surface.
Thickness of the coating layer applied to the surface of the product or one of its parts.
Environmental corrosivity category for which resistance of the product material or protective coating is declared.
Duration of salt-spray testing withstood by the product or coating under the declared conditions.
Primary material from which the product is manufactured.
Mounting and Installation41
Permissible spatial orientation of the component during installation and operation.
Installation arrangement permitted by the product design, such as wall-mounted, flush-mounted, floor-mounted, or another specified mounting type.
Method used to mechanically secure the product to a support, surface, or load-bearing structure.
Type of surface or supporting base to which the product may be fixed.
Number of holes provided in the product for mechanical fixing.
Diameter of the hole provided for a fixing element used when mounting the product.
Geometric shape of the hole intended for mechanical fixing of the product.
Distance between the centres of mounting holes in the horizontal direction.
Distance between the centres of mounting holes in the vertical direction.
Horizontal dimension of the mounting pattern between the outermost fixing points of the product.
Vertical dimension of the mounting pattern between the outermost fixing points of the product.
Size designation of the screw, bolt, or other threaded fastener used for mounting the product.
Designation of the thread provided in the product's mounting holes or fixing elements.
Tightening torque recommended or permitted for fasteners during product installation.
Indicates whether the required fasteners are included with the product.
Type of anchors compatible with the specified product fixing method.
Number of anchors provided or required for standard product fixing.
Size or designation of the anchor specified for product installation.
Indicates whether the manufacturer requires the product to be mechanically fixed to the floor or supporting base.
Number of holes in the product base intended for anchoring it to the floor.
Nominal diameter of a hole in the product base intended for installation of a floor anchor.
Horizontal distance between the centres of corresponding floor anchoring points along the X axis.
Plan-view distance between the centres of corresponding floor anchoring points along the Y axis.
Indicates whether a mounting plate is included with the product.
Indicates whether the position of the mounting plate inside the product can be adjusted.
Full range of mounting plate movement in the depth direction where adjustment is provided.
Number of points by which the mounting plate is fixed to the product's supporting structure.
Maximum mass of equipment permitted to be installed on the mounting plate.
Number of independent EV charger or wallbox mounting positions provided by a pedestal, column or mounting structure.
Indicates that two charging units can be installed on opposite sides of the same pedestal or mounting structure.
Indicates that the manufacturer requires a dedicated structural foundation or installation base for the product.
Manufacturer-supported or required foundation construction type for installation of the product.
Minimum manufacturer-declared foundation width required for installation.
Minimum manufacturer-declared foundation depth in plan required for installation.
Minimum manufacturer-declared vertical foundation dimension required for installation.
Overall physical width of the structural base plate used to mount the product to the supporting surface.
Overall physical front-to-rear dimension of the structural base plate.
Physical thickness of the structural mounting base plate.
Primary material of the structural base plate used for floor or foundation mounting.
Manufacturer-declared depth by which the relevant pedestal, foundation element or mounting component is installed below finished ground level.
Indicates that a drilling, anchoring or foundation-positioning template is supplied for installation.
Cable Entries12
Sides or areas of the product where the design provides for cable and conductor entry.
Design method used to route cables or conductors into the product.
Number of separate cable entries provided on the bottom side of the product.
Number of removable or fixed plates intended for organizing cable entries.
Sides or areas of the product in which gland plates are installed or may be installed.
Material from which the plate used to organize cable entries is made.
External horizontal dimension of the gland plate.
External vertical dimension of the gland plate.
Distance between the two main surfaces of the gland plate.
Indicates whether the gland plate can be removed without damaging the product enclosure.
Indicates that supply, communication or control cables can enter the installed product directly from underground infrastructure.
Indicates that installation cables can be routed internally through the pedestal, column or structural mounting assembly.
Protection and Safety2
Degree of enclosure protection against access to hazardous parts and ingress of solid objects and water, designated by the IP code.
Class of enclosure resistance to external mechanical impacts designated by the IK code.
Environmental Conditions49
Indicates whether the material and coating are designed to withstand ultraviolet radiation.
Indicates whether the product is designed for the combination of weather influences specified by the manufacturer.
Minimum ambient temperature at which normal operation of the product is permitted.
Maximum ambient temperature at which normal operation of the product is permitted.
Minimum ambient temperature permitted during storage of the product while not in operation.
Maximum ambient temperature permitted during storage of the product while not in operation.
Maximum relative air humidity permitted for the declared operating or test condition.
Maximum altitude above sea level at which the product may be installed without exceeding the declared conditions.
Types of climatic environment for which the manufacturer intends the product to be operated.
Classification level of the severity of climatic, mechanical, or other external influences.
Degree of protection of the installation location from direct exposure to the external environment.
Indicates whether the product's resistance to solar radiation has been verified.
Maximum solar radiation flux density permitted under the declared operating conditions.
Permissible or intended level of direct sunlight exposure of the product.
Permissible or intended level of direct rain exposure of the product.
Maximum rainfall intensity for which product suitability is declared.
Indicates whether the product design is intended to withstand the declared wind loads.
Maximum wind speed at which the installed product retains its declared suitability.
Maximum wind-load pressure permitted for the installed product.
Indicates whether the product is designed to withstand mechanical snow loading.
Maximum uniformly distributed snow load permitted by the product design.
Indicates whether the product is designed to withstand mechanical loading caused by ice formation.
Maximum ice-load mass per unit area permitted for the product.
Indicates whether the product's resistance to repeated freeze-thaw cycles has been verified.
Number of freeze-thaw cycles performed or required during testing.
Indicates whether the product may be operated in an environment with elevated sand and dust content.
Maximum concentration of airborne dust permitted under the declared operating conditions.
Indicates whether the product may be operated in an atmosphere with elevated salt content.
Indicates whether the product is designed for operation in a coastal atmosphere.
Indicates whether the product is designed for operation in a marine environment with characteristic salt and humidity exposure.
Indicates whether the product is designed for operation on marine and other offshore installations.
Indicates whether the product is designed for operation in an industrial atmosphere with characteristic contaminants.
Indicates whether the product is designed for operation in an agricultural environment with characteristic contaminants and humidity.
Indicates whether the product may be operated in an environment containing ammonia under the declared conditions.
Indicates whether the product may be operated in an environment containing sulfur dioxide under the declared conditions.
Indicates whether the product may be operated in an environment containing hydrogen sulfide under the declared conditions.
Indicates whether the product's resistance to vibration has been verified under the declared conditions.
Lower limit of vibration frequency applied or permitted in the relevant test.
Upper limit of vibration frequency applied or permitted in the relevant test.
Amplitude or test-method-specified acceleration of vibration applied during product testing.
Amplitude of mechanical displacement under low-frequency vibration.
Duration of vibration exposure during the specified product test.
Spatial axes along which vibration testing of the product is performed.
Indicates whether the product's resistance to short-duration mechanical shocks has been verified.
Maximum acceleration generated during mechanical shock testing of the product.
Duration of an individual mechanical shock pulse during product testing.
Number of shock impacts applied along each test axis.
Spatial axes along which mechanical shock testing of the product is performed.
Classification designation of environmental conditions during stationary operation of the product.
Included Equipment4
Indicates whether an installation hardware kit is included in the product's standard equipment.
Indicates whether documentation is included in the product's standard supply.
Indicates whether an installation manual is included with the product.
Indicates whether assembly instructions are included with the product.
Standards and Compliance3
Indicates whether the CE marking is applied to the product where applicable.
Indicates whether the manufacturer declares compliance of the product with applicable REACH Regulation requirements.
Indicates whether a declaration of compliance of the materials used with specified requirements or restrictions is available.
Logistics12
Mass of the product together with its individual packaging and the accessories included in it.
External horizontal dimension of the product's individual package.
External vertical dimension of the product's individual package.
External depth dimension of the product's individual package.
Calculated or declared external volume of the product's individual package.
Design type of the product's individual or transport packaging.
Primary materials from which the product packaging is made.
Mass of the empty packaging without the product and its accessories.
Number of individual products contained in one packaging unit at the specified level.
Indicates whether the packaging used is declared recyclable as secondary raw material.
Indicates whether the packaging is designed for reuse without changing its primary purpose.
Indicates whether the packaging is intended to be returned to the supplier, manufacturer, or another participant in the logistics chain.