Device description

Illuminated Push Button

Panel-mounted push button combining a control function with local visual indication.

Illuminated Push Button is a manually operated control element intended to generate an electrical command by mechanically actuating one or more contact blocks.

Selection considers operator type and action, color, shape, diameter, height, operating force and travel, bezel material, and anti-rotation features. The number and configuration of contact blocks, AC-15 and DC-13 contact ratings, minimum switching characteristics, and electrical endurance are also relevant.

Illumination may cover the button face, ring, or another area. Illumination-circuit configuration, electrical separation from control contacts, replaceable illumination modules, and operator legends should be considered.

For panel mounting, panel thickness, front projection, rear mounting depth, fixing method, gasket, and anti-rotation opening requirements are considered.

Components in this subcategory

Illuminated push buttons with contact blocks and light modules for machine control.

Available parameters

Illuminated Push Button

142 parameters
General3
Product Series

Commercial or technical designation of a manufacturer's product family sharing a common design and compatible characteristics.

Operator Type

Mechanical type of the manually operated control element used to actuate the device.

Operator Action Type

Mechanical operating behavior of the operator with respect to maintained, momentary or latched states.

Dimensions15
Widthmm

External horizontal dimension of the product between its outermost lateral points.

Heightmm

External vertical dimension of the product from its lowest to its highest point.

Depthmm

External distance between the foremost and rearmost surfaces of the product.

Diametermm

Transverse dimension of a product or its circular element measured through the centre between opposite points of the circumference.

Net Weightkg

Mass of the product itself, excluding transport packaging, additional accessories, and external equipment.

Mounting Hole Diametermm

Diameter of the hole provided for a fixing element used when mounting the product.

Installation Cutout Widthmm

Horizontal dimension of the mounting cutout or opening required to install the product in a prepared surface or recess.

Installation Cutout Heightmm

Vertical dimension of the mounting cutout or opening required to install the product in a prepared surface or recess.

Minimum Panel Thicknessmm

Minimum mounting-panel thickness accepted by the product mounting system.

Maximum Panel Thicknessmm

Maximum mounting-panel thickness accepted by the product mounting system.

Front Projectionmm

Maximum distance that the installed product projects forward from the finished mounting-panel surface.

Rear Mounting Depthmm

Required depth behind the mounting-panel surface for the installed product, excluding external conductor bend allowance unless otherwise stated.

Front Bezel Diametermm

Maximum external diameter of the visible front bezel or mounting ring where the panel-mounted product has a circular front geometry.

Operator Diametermm

Maximum external diameter of the manually operated head where a circular dimension is applicable.

Operator Heightmm

External height or projection of the manually operated element above its reference mounting surface.

Materials and Finish6
Material

Primary material from which the product is manufactured.

Color

Primary visually perceived colour of the product's external surface.

Operator Color

Visible color of the push-button head, selector handle, key operator or equivalent manually operated element.

Operator Shape

Geometric form of the manually operated head or handle.

Bezel Material

Primary material of the visible bezel or front mounting ring surrounding the operator.

Bezel Color

Visible color of the operator bezel or front mounting ring.

Mounting and Installation9
Mounting Type

Installation arrangement permitted by the product design, such as wall-mounted, flush-mounted, floor-mounted, or another specified mounting type.

Mounting Method

Method used to mechanically secure the product to a support, surface, or load-bearing structure.

Orientation

Permissible spatial orientation of the component during installation and operation.

Panel Fixing Method

Mechanical method used to secure the product to the mounting panel after insertion through the panel opening.

Anti-Rotation Notch Required

Indicates that the panel opening requires an additional notch, flat or equivalent feature to prevent rotation of the installed product.

Mounting Gasket Included

Indicates that a gasket or sealing element used between the product and mounting panel is supplied with the product.

Mounting Ring Included

Indicates that the retaining or fixing ring required for mounting the product in the panel is supplied.

Mounting Nut Included

Indicates that a threaded fixing nut required for panel installation is supplied with the product.

Mounting Hardware Included

Indicates that the general fixing hardware required for the declared installation method is supplied with the product.

Electrical Parameters43
Contact Block Count

Number of contact blocks installed as part of the complete control device.

Maximum Contact Block Count

Maximum number of compatible contact blocks that may be mechanically fitted to the operator assembly.

Contact Block Replaceable

Indicates that the contact block can be removed and replaced independently of the operator.

Contact Blocks Stackable

Indicates that multiple compatible contact blocks can be mechanically stacked behind the operator.

Normally Open Control Contact Count

Number of normally open control-circuit contact elements provided by the complete device.

Normally Closed Control Contact Count

Number of normally closed control-circuit contact elements provided by the complete device.

Changeover Control Contact Count

Number of changeover control-circuit contact sets provided by the complete device.

Maximum Control Contact Rated Operational VoltageV

Maximum manufacturer-declared rated operational voltage Ue of the control contact circuit.

Control Contact Rated Insulation VoltageV

Rated insulation voltage Ui specifically declared for the control contact circuit.

Control Contact Rated Impulse Withstand VoltagekV

Rated impulse withstand voltage Uimp specifically declared for the control contact circuit.

Control Contact Conventional Free-Air Thermal CurrentA

Conventional free-air thermal current Ith of the control contact element.

Control Contact Rated Operational Current AC-15A

Rated operational current Ie of the control contact for utilization category AC-15 at the associated reference voltage.

Control Contact AC-15 Reference VoltageV

Operational voltage associated with the stored AC-15 control-contact rated current.

Control Contact Rated Operational Current DC-13A

Rated operational current Ie of the control contact for utilization category DC-13 at the associated reference voltage.

Control Contact DC-13 Reference VoltageV

Operational voltage associated with the stored DC-13 control-contact rated current.

Control Contact Minimum Switching VoltageV

Minimum switching voltage for which reliable operation of the control contact is declared.

Control Contact Minimum Switching CurrentA

Minimum switching current for which reliable operation of the control contact is declared.

Control Contact Material

Electrical contact material or contact-material system used by the control contact element.

Control Contact ResistancemΩ

Manufacturer-declared resistance of a closed control contact under the specified measurement conditions.

Control Contact Short-Time Withstand Current 1 sA

Manufacturer-declared short-time withstand current of the control contact circuit for 1 second.

Control Contact Short-Time Withstand Current 0.1 sA

Manufacturer-declared short-time withstand current of the control contact circuit for 0.1 second.

Control Contact Switching Sequence

Switching sequence between associated control contact elements during a change of operator position.

Maximum Control Contact Switching Frequency AC-15cycles/h

Maximum manufacturer-declared electrical switching frequency under AC-15 conditions.

Maximum Control Contact Switching Frequency DC-13cycles/h

Maximum manufacturer-declared electrical switching frequency under DC-13 conditions.

Utilization Category

Manufacturer-declared utilization category defining the load characteristics and switching conditions according to the applicable standard.

Rated Conditional Short-Circuit CurrentkA

Prospective short-circuit current that the product can withstand when the specified external protective device is used.

Backup Protection Device Type

Type of upstream overcurrent protective device permitted or required by the manufacturer for the declared conditional short-circuit withstand rating or SCCR.

Short-Circuit Rating Conditions

Conditions associated with the declared short-circuit withstand rating or SCCR, including required type, class, rating, or other restrictions of the upstream protective device.

Connection Point Count

Total number of electrical connection points provided by the product.

Control Terminal Connection Type

Conductor connection technology used specifically for the control-circuit terminals.

Minimum Control Terminal Conductor Cross-Sectionmm²

Minimum conductor cross-section accepted by the control-circuit terminal.

Maximum Control Terminal Conductor Cross-Sectionmm²

Maximum conductor cross-section accepted by the control-circuit terminal.

Control Terminal Tightening TorqueNm

Manufacturer-declared tightening torque specifically for a screw-type control-circuit terminal.

Rated Operational VoltageV

Operating-circuit voltage with reference to which the product's performance characteristics are specified.

Rated Insulation VoltageV

Voltage with reference to which the product's insulation clearances and dielectric properties are specified.

Rated Impulse Withstand VoltagekV

Peak value of an impulse voltage of specified waveform that the product insulation must withstand without breakdown.

Illumination Circuit Configuration

Electrical relationship between the illumination circuit, control contacts and product supply.

Illumination Circuit Separate from Control Contacts

Indicates that the illumination element has an electrically separate circuit from the operator control contacts.

Minimum Indicator VoltageV

Minimum operating voltage of the integrated electrical visual indicator.

Maximum Indicator VoltageV

Maximum operating voltage of the integrated electrical visual indicator.

Minimum Indicator CurrentA

Minimum operating current of the integrated electrical visual indicator.

Maximum Indicator CurrentA

Maximum operating current of the integrated electrical visual indicator.

Indicator Current Type

Type of electrical current for which the integrated visual indicator is designed.

Protection and Safety7
IP Rating

Degree of enclosure protection against access to hazardous parts and ingress of solid objects and water, designated by the IP code.

Front IP Rating

Ingress protection rating applicable specifically to the installed front face of the product.

Rear IP Rating

Ingress protection rating applicable specifically to the rear portion of the installed product.

IK Rating

Class of enclosure resistance to external mechanical impacts designated by the IK code.

Finger-Safe

Indicates whether the design prevents finger access to hazardous live parts in the intended condition.

Touch-Safe

Indicates whether the design provides protection against accidental contact with hazardous live parts.

Overvoltage Category

Category characterizing the expected level of impulse overvoltages at the product's point of use.

Environmental Conditions12
Minimum Operating Temperature°C

Minimum ambient temperature at which normal operation of the product is permitted.

Maximum Operating Temperature°C

Maximum ambient temperature at which normal operation of the product is permitted.

Minimum Storage Temperature°C

Minimum ambient temperature permitted during storage of the product while not in operation.

Maximum Storage Temperature°C

Maximum ambient temperature permitted during storage of the product while not in operation.

Maximum Relative Humidity%

Maximum relative air humidity permitted for the declared operating or test condition.

Maximum Installation Altitudem

Maximum altitude above sea level at which the product may be installed without exceeding the declared conditions.

Vibration Accelerationm/s²

Amplitude or test-method-specified acceleration of vibration applied during product testing.

Shock Accelerationm/s²

Maximum acceleration generated during mechanical shock testing of the product.

UV Resistant

Indicates whether the material and coating are designed to withstand ultraviolet radiation.

Salt Spray Resistanceh

Duration of salt-spray testing withstood by the product or coating under the declared conditions.

Chemical Resistance

Groups of chemicals or environments whose effects the product can withstand under the declared conditions.

Pollution Degree

Degree of pollution of the surrounding microenvironment considered when selecting insulation distances and product characteristics.

Included Equipment15
Delivery Configuration

Physical product configuration supplied under the catalog number, such as a complete assembled device or a modular operator component.

Legend Plate Included

Indicates that a separate external legend, identification or marking plate is supplied with the product.

Legend Plate Replaceable

Indicates that the external legend or identification plate can be replaced independently.

Terminal Cover Included

Indicates whether insulating terminal covers or protective terminal shrouds are supplied with the product.

Terminal Marking Present

Indicates that electrical connection terminals are individually identified by manufacturer-applied markings.

Operator Illumination Present

Indicates that the manually operated control element incorporates or supports an electrically illuminated visible area.

Illumination Area

Physical portions of the operator or indicator that emit or transmit the illumination.

Illumination Module Replaceable

Indicates that the complete illumination module can be removed and replaced independently of the operator or device body.

Light Source Type

Primary light-generation technology used by the visual indicator or signaling device.

Light Source Replaceable

Indicates whether the light-generating element can be replaced according to the manufacturer instructions.

Light Source Lifetimeh

Manufacturer-declared operating lifetime of the light source under specified conditions.

Lens Color

Physical color or tint of the optical lens or diffuser.

Lens Material

Primary material used for the optical lens, diffuser or light cover.

Supported Signal Colors

Colors that can be generated by a multicolor or configurable visual signaling device.

Multicolor Operation Supported

Indicates that one optical signaling element can generate more than one signal color.

Special Features11
Anti-Rotation Feature Present

Indicates that the operator assembly includes a mechanical feature that prevents unintended rotation in the mounting panel.

Operating ForceN

Manufacturer-declared mechanical force required to actuate the operator.

Operator Travelmm

Mechanical displacement of the operator between its normal and fully actuated positions.

Mechanical Endurancecycles

Declared number of mechanical operating cycles that the product can perform without electrical switching load.

Electrical Endurancecycles

Declared number of electrical load-switching cycles under the conditions specified by the manufacturer.

Operator Guard Present

Indicates that a protective collar, shroud or guard intended to reduce accidental actuation is integrated or supplied as part of the operator assembly.

Spring Return Configuration

Mechanical spring-return behavior of a selector or rotary operator.

Operator Legend Present

Indicates that the operator face or illuminated area contains a text, symbol or equivalent functional legend.

Operator Legend Type

General form of the visible functional legend provided on the operator or indicator face.

Operator Legend Content

Manufacturer-provided text, symbol designation or other fixed legend identifying the operator function.

Indicator Test Supported

Indicates that the product provides a function for testing its visual indicators.

Standards and Compliance7
Certification and Conformity Marks

Certification, market-approval, or conformity marks applicable to the product.

CE Marked

Indicates whether the CE marking is applied to the product where applicable.

RoHS Compliant

Indicates whether product compliance with applicable RoHS restrictions on hazardous substances has been declared.

REACH Compliant

Indicates whether the manufacturer declares compliance of the product with applicable REACH Regulation requirements.

Documentation Included

Indicates whether documentation is included in the product's standard supply.

Documentation Types Included

Types of technical documentation supplied with or explicitly included for the product.

IEC 60947-5-1 Compliant

Compliance with applicable IEC 60947-5-1 requirements for control-circuit devices and switching elements.

Logistics14
Gross Weightkg

Mass of the product together with its individual packaging and the accessories included in it.

Package Widthmm

External horizontal dimension of the product's individual package.

Package Heightmm

External vertical dimension of the product's individual package.

Package Depthmm

External depth dimension of the product's individual package.

Package Volumem³

Calculated or declared external volume of the product's individual package.

Packaging Type

Design type of the product's individual or transport packaging.

Packaging Material

Primary materials from which the product packaging is made.

Package Tare Weightkg

Mass of the empty packaging without the product and its accessories.

Units per Package

Number of individual products contained in one packaging unit at the specified level.

Recyclable Packaging

Indicates whether the packaging used is declared recyclable as secondary raw material.

Reusable Packaging

Indicates whether the packaging is designed for reuse without changing its primary purpose.

Returnable Packaging

Indicates whether the packaging is intended to be returned to the supplier, manufacturer, or another participant in the logistics chain.

Country of Origin

Country of origin of the goods declared for customs or commercial purposes.

HS Code

Commodity code under the international Harmonized Commodity Description and Coding System.