TRASA3 Knowledge Base

Electrical Component Parameter Reference

An open technical reference for electrical component types, their applications, and selection parameters.

This material is also available in PL and RU.

Device description

Voltage Indicator

Device for visual indication of the presence or absence of voltage in one or more monitored circuits.

A voltage indicator monitors electrical voltage and provides local visual information about voltage presence, absence, or another specified state.

Depending on the design, it may support one or more channels or phases and may use defined thresholds for recognizing voltage presence and absence. Input impedance of the monitoring circuit is also relevant.

Selection criteria include voltage range, number of monitored paths, indication thresholds, connection arrangement, visual indication layout, and installation conditions.

Components in this subcategory

Single- and multi-channel voltage indicators for distribution boards, control cabinets, and electrical equipment.

Available parameters

Voltage Indicator

88 parameters
General1
Product Series

Commercial or technical designation of a manufacturer's product family sharing a common design and compatible characteristics.

Dimensions4
Widthmm

External horizontal dimension of the product between its outermost lateral points.

Heightmm

External vertical dimension of the product from its lowest to its highest point.

Depthmm

External distance between the foremost and rearmost surfaces of the product.

Net Weightkg

Mass of the product itself, excluding transport packaging, additional accessories, and external equipment.

Materials and Finish2
Material

Primary material from which the product is manufactured.

Color

Primary visually perceived colour of the product's external surface.

Mounting and Installation3
Mounting Type

Installation arrangement permitted by the product design, such as wall-mounted, flush-mounted, floor-mounted, or another specified mounting type.

Mounting Method

Method used to mechanically secure the product to a support, surface, or load-bearing structure.

Orientation

Permissible spatial orientation of the component during installation and operation.

Electrical Parameters29
Supply Current Type

Type of electrical current for which the product's main supply circuit is intended.

Rated VoltageV

Voltage value assigned to the product by the manufacturer for specified application conditions and characteristics.

Rated CurrentA

Current assigned to the product by the manufacturer for the declared operating and thermal conditions.

Rated FrequencyHz

AC frequency assigned to the product for normal operating conditions.

Minimum Input VoltageV

Minimum continuous input voltage within the manufacturer-declared operating input range.

Maximum Input VoltageV

Maximum continuous input voltage within the manufacturer-declared operating input range.

Power ConsumptionW

Electrical power consumed by the product itself in the declared normal operating mode.

Maximum Supply CurrentA

Maximum manufacturer-declared current drawn from the electrical supply during normal operation.

Connection Point Count

Total number of electrical connection points provided by the product.

Control Terminal Connection Type

Conductor connection technology used specifically for the control-circuit terminals.

Minimum Control Terminal Conductor Cross-Sectionmm²

Minimum conductor cross-section accepted by the control-circuit terminal.

Maximum Control Terminal Conductor Cross-Sectionmm²

Maximum conductor cross-section accepted by the control-circuit terminal.

Control Terminal Tightening TorqueNm

Manufacturer-declared tightening torque specifically for a screw-type control-circuit terminal.

Terminal Marking Present

Indicates that electrical connection terminals are individually identified by manufacturer-applied markings.

Monitored Voltage Current Type

Current type of the monitored voltage measuring circuit: AC, DC or AC/DC.

Minimum Monitored VoltageV

Lower limit of the manufacturer-declared voltage measuring range.

Maximum Monitored VoltageV

Upper limit of the manufacturer-declared voltage measuring range.

Voltage Measurement Accuracy%

Manufacturer-declared accuracy of voltage measurement where expressed as a single percentage value.

Minimum Monitored Voltage FrequencyHz

Minimum AC measuring-signal frequency supported by the voltage monitoring function.

Maximum Monitored Voltage FrequencyHz

Maximum AC measuring-signal frequency supported by the voltage monitoring function.

Phase-to-Phase Voltage Monitoring Supported

Indicates that the product evaluates or indicates phase-to-phase voltages of the monitored multiphase system.

Phase-to-Neutral Voltage Monitoring Supported

Indicates that the product evaluates or indicates phase-to-neutral voltages of the monitored electrical system.

Monitored Phase Count

Number of phase conductors independently monitored or evaluated by the device.

Monitoring Supply Mode

Relationship between the monitored measuring circuit and the electrical supply required for operation of the monitoring or indication function.

Monitored Voltage Input ImpedanceΩ

Manufacturer-declared input impedance presented by the monitored-voltage measuring or indication circuit.

Response Timens

Manufacturer-declared response time of the relevant protective function of the product to a surge impulse.

Voltage Presence ThresholdV

Manufacturer-declared voltage threshold at or above which the monitored circuit is recognized or indicated as voltage present.

Voltage Absence ThresholdV

Manufacturer-declared voltage threshold at or below which the monitored circuit is recognized or indicated as voltage absent.

Monitoring Channel Count

Number of independently monitored electrical circuits, phases or input channels evaluated by the device.

Protection and Safety6
IP Rating

Degree of enclosure protection against access to hazardous parts and ingress of solid objects and water, designated by the IP code.

IK Rating

Class of enclosure resistance to external mechanical impacts designated by the IK code.

Finger-Safe

Indicates whether the design prevents finger access to hazardous live parts in the intended condition.

Touch-Safe

Indicates whether the design provides protection against accidental contact with hazardous live parts.

Overvoltage Category

Category characterizing the expected level of impulse overvoltages at the product's point of use.

Pollution Degree

Degree of pollution of the surrounding microenvironment considered when selecting insulation distances and product characteristics.

Environmental Conditions8
Minimum Operating Temperature°C

Minimum ambient temperature at which normal operation of the product is permitted.

Maximum Operating Temperature°C

Maximum ambient temperature at which normal operation of the product is permitted.

Minimum Storage Temperature°C

Minimum ambient temperature permitted during storage of the product while not in operation.

Maximum Storage Temperature°C

Maximum ambient temperature permitted during storage of the product while not in operation.

Maximum Relative Humidity%

Maximum relative air humidity permitted for the declared operating or test condition.

Maximum Installation Altitudem

Maximum altitude above sea level at which the product may be installed without exceeding the declared conditions.

Vibration Accelerationm/s²

Amplitude or test-method-specified acceleration of vibration applied during product testing.

Shock Accelerationm/s²

Maximum acceleration generated during mechanical shock testing of the product.

Included Equipment8
Status Indicator Color

Color of the integrated visual status indicator or LED.

Light Source Type

Primary light-generation technology used by the visual indicator or signaling device.

Supported Signal Colors

Colors that can be generated by a multicolor or configurable visual signaling device.

Multicolor Operation Supported

Indicates that one optical signaling element can generate more than one signal color.

Indicator Channel Count

Number of independently identifiable visual indication channels provided by the product.

Front Indication Layout

Physical arrangement of visual indication elements on the front face of the product.

Indicator Window Count

Number of separate visible indication windows, lenses or front-panel indication fields.

Channel Marking Field Present

Indicates that the front panel provides a dedicated field for identifying the corresponding channel, phase or function.

Special Features7
Indicator Test Supported

Indicates that the product provides a function for testing its visual indicators.

Front Test Button Present

Indicates that a dedicated physical TEST control is accessible from the front of the device.

Voltage Presence Indication Supported

Indicates that the device provides an explicit visual indication when the monitored voltage is considered present.

Voltage Absence Indication Supported

Indicates that the device provides an explicit indication when the monitored voltage is considered absent.

Indicated Conditions

Electrical states or conditions that can be explicitly distinguished by the local indication system.

Independent Phase Indication Supported

Indicates that the presence or condition of individual phases can be indicated independently rather than only as one combined system state.

Front Reset Button Present

Indicates that a dedicated physical RESET control is accessible from the front of the device.

Standards and Compliance6
Certification and Conformity Marks

Certification, market-approval, or conformity marks applicable to the product.

CE Marked

Indicates whether the CE marking is applied to the product where applicable.

RoHS Compliant

Indicates whether product compliance with applicable RoHS restrictions on hazardous substances has been declared.

REACH Compliant

Indicates whether the manufacturer declares compliance of the product with applicable REACH Regulation requirements.

Documentation Included

Indicates whether documentation is included in the product's standard supply.

Documentation Types Included

Types of technical documentation supplied with or explicitly included for the product.

Logistics14
Gross Weightkg

Mass of the product together with its individual packaging and the accessories included in it.

Package Widthmm

External horizontal dimension of the product's individual package.

Package Heightmm

External vertical dimension of the product's individual package.

Package Depthmm

External depth dimension of the product's individual package.

Package Volumem³

Calculated or declared external volume of the product's individual package.

Packaging Type

Design type of the product's individual or transport packaging.

Packaging Material

Primary materials from which the product packaging is made.

Package Tare Weightkg

Mass of the empty packaging without the product and its accessories.

Units per Package

Number of individual products contained in one packaging unit at the specified level.

Recyclable Packaging

Indicates whether the packaging used is declared recyclable as secondary raw material.

Reusable Packaging

Indicates whether the packaging is designed for reuse without changing its primary purpose.

Returnable Packaging

Indicates whether the packaging is intended to be returned to the supplier, manufacturer, or another participant in the logistics chain.

Country of Origin

Country of origin of the goods declared for customs or commercial purposes.

HS Code

Commodity code under the international Harmonized Commodity Description and Coding System.