Device description

DIN Rail RJ11 Socket

Modular RJ11 interface for telephone and other low-voltage telecommunication lines, intended for DIN rail installation.

A DIN rail RJ11 socket is used to organize telephone or similar telecommunication connections inside a cabinet.

The module may serve one or more lines and may have different numbers of physical connector positions and installed contacts.

Correct integration requires attention to telephone-pair mapping and preservation of Tip/Ring polarity.

Selection criteria include number of lines and ports, supported services, maximum line and ringing voltages, line current, and compatibility with a replaceable Keystone module.

Components in this subcategory

DIN rail RJ11 sockets and telephone modules for telecommunication cabinets.

Available parameters

DIN Rail RJ11 Socket

69 parameters
General1
Product Series

Commercial or technical designation of a manufacturer's product family sharing a common design and compatible characteristics.

Dimensions4
Widthmm

External horizontal dimension of the product between its outermost lateral points.

Heightmm

External vertical dimension of the product from its lowest to its highest point.

Depthmm

External distance between the foremost and rearmost surfaces of the product.

Net Weightkg

Mass of the product itself, excluding transport packaging, additional accessories, and external equipment.

Capacity and Layout5
RJ11 Port Count

Number of physical RJ11-compatible modular socket interfaces provided by the product.

Modular Connector Position Count

Number of physical contact positions in the modular connector interface, for example 8 positions for an 8P8C RJ45 interface.

Modular Connector Contact Count

Number of electrically populated contacts in the modular connector interface.

Wire Pair Count

Number of balanced wire pairs connected through, transmitted through, or protected by the product.

Telephone Line Count

Number of independent telephone or analogue telecommunications lines carried by the product.

Materials and Finish2
Material

Primary material from which the product is manufactured.

Color

Primary visually perceived colour of the product's external surface.

Mounting and Installation4
Mounting Type

Installation arrangement permitted by the product design, such as wall-mounted, flush-mounted, floor-mounted, or another specified mounting type.

Mounting Method

Method used to mechanically secure the product to a support, surface, or load-bearing structure.

Orientation

Permissible spatial orientation of the component during installation and operation.

Keystone Module Compatible

Indicates that the DIN-rail carrier or socket assembly accepts a replaceable standard-format keystone data module.

Electrical Parameters20
Input Connector Type

Type of connector, terminal, or other electrical connection system on the input or first side of the product's signal path.

Output Connector Type

Type of connector, terminal, or other electrical connection system on the output or second side of the product's signal path.

Input Connector Gender

Mechanical form, contact gender, or corresponding mating arrangement of the input connector.

Output Connector Gender

Mechanical form, contact gender, or corresponding mating arrangement of the output connector.

Supported Telecom Services

Telecommunications service types for which the passive connector or signal path is declared suitable.

Telephone Pair Mapping

Electrical mapping of telephone conductor pairs between the two sides of the product.

Tip/Ring Polarity Preserved

Indicates that Tip and Ring conductor polarity is preserved through the passive telephone signal path.

Maximum Telecom Line VoltageV

Maximum manufacturer-declared continuous telecommunications line voltage supported by the signal path.

Maximum Telecom Ringing VoltageV

Maximum manufacturer-declared ringing or call-signalling voltage supported by the telephone signal path.

Maximum Telecom Line CurrentA

Maximum manufacturer-declared continuous current supported by the telecommunications signal path.

Minimum Transmission FrequencyMHz

Lower limit of the manufacturer-declared frequency range for signal transmission through the product.

Maximum Transmission FrequencyMHz

Upper limit of the manufacturer-declared frequency range for signal transmission through the product.

Maximum Data RateMbps

Maximum manufacturer-declared digital data rate through the relevant interface or passive signal path.

Characteristic ImpedanceOhm

Characteristic or wave impedance of the signal path for which the product is intended.

Maximum Insertion LossdB

Maximum manufacturer-declared signal insertion loss within the specified transmission range.

Minimum Return LossdB

Minimum manufacturer-declared return loss of the signal path within the specified transmission range.

Power over Signal Line Supported

Indicates whether operating or remote power can be transmitted simultaneously through the protected signal, information, or telecommunication line.

DC Pass-Through Supported

Indicates whether DC supply voltage or current can pass through the protected signal path.

Maximum DC Pass-Through VoltageV

Maximum manufacturer-declared DC voltage that may pass through the signal path when DC pass-through is supported.

Maximum DC Pass-Through CurrentA

Maximum manufacturer-declared DC current that may pass through the signal path when DC pass-through is supported.

Protection and Safety7
IP Rating

Degree of enclosure protection against access to hazardous parts and ingress of solid objects and water, designated by the IP code.

IK Rating

Class of enclosure resistance to external mechanical impacts designated by the IK code.

Halogen-Free

Indicates whether the product material is classified as halogen-free according to the characteristics declared by the manufacturer.

Silicone-Free

Indicates whether the absence of silicone has been declared for materials or process substances associated with the product.

Socket Protective Cover Present

Indicates that the socket-outlet includes a protective lid, flap or cap covering the mating interface when not in use.

Socket Protective Cover Type

Mechanical type of protective cover fitted to the socket-outlet.

Socket Protective Cover Lockable

Indicates that the socket protective cover can be mechanically locked or secured in the closed position.

Environmental Conditions6
Minimum Operating Temperature°C

Minimum ambient temperature at which normal operation of the product is permitted.

Maximum Operating Temperature°C

Maximum ambient temperature at which normal operation of the product is permitted.

Minimum Storage Temperature°C

Minimum ambient temperature permitted during storage of the product while not in operation.

Maximum Storage Temperature°C

Maximum ambient temperature permitted during storage of the product while not in operation.

Maximum Relative Humidity%

Maximum relative air humidity permitted for the declared operating or test condition.

Maximum Installation Altitudem

Maximum altitude above sea level at which the product may be installed without exceeding the declared conditions.

Special Features1
Network Module Replaceable

Indicates that the data connector module can be removed and replaced independently of the DIN-rail carrier or housing.

Standards and Compliance5
Certification and Conformity Marks

Certification, market-approval, or conformity marks applicable to the product.

CE Marked

Indicates whether the CE marking is applied to the product where applicable.

RoHS Compliant

Indicates whether product compliance with applicable RoHS restrictions on hazardous substances has been declared.

REACH Compliant

Indicates whether the manufacturer declares compliance of the product with applicable REACH Regulation requirements.

Documentation Included

Indicates whether documentation is included in the product's standard supply.

Logistics14
Gross Weightkg

Mass of the product together with its individual packaging and the accessories included in it.

Package Widthmm

External horizontal dimension of the product's individual package.

Package Heightmm

External vertical dimension of the product's individual package.

Package Depthmm

External depth dimension of the product's individual package.

Package Volumem³

Calculated or declared external volume of the product's individual package.

Packaging Type

Design type of the product's individual or transport packaging.

Packaging Material

Primary materials from which the product packaging is made.

Package Tare Weightkg

Mass of the empty packaging without the product and its accessories.

Units per Package

Number of individual products contained in one packaging unit at the specified level.

Recyclable Packaging

Indicates whether the packaging used is declared recyclable as secondary raw material.

Reusable Packaging

Indicates whether the packaging is designed for reuse without changing its primary purpose.

Returnable Packaging

Indicates whether the packaging is intended to be returned to the supplier, manufacturer, or another participant in the logistics chain.

Country of Origin

Country of origin of the goods declared for customs or commercial purposes.

HS Code

Commodity code under the international Harmonized Commodity Description and Coding System.