TRASA3 Knowledge Base

Electrical Component Parameter Reference

An open technical reference for electrical component types, their applications, and selection parameters.

This material is also available in PL and RU.

Device description

Strain Relief

Mechanical element that prevents cable pulling forces and movement from being transferred to conductors, terminals and electrical contacts.

A strain-relief device grips the cable sheath or body so that external mechanical force is not transmitted directly to conductors and contact points.

It may be implemented as a clamp, bracket, rail, comb, tie or as an integrated part of a cable gland or connector. The retention method has to suit cable diameter, sheath material and flexibility.

Important parameters include retention force, resistance to vibration and repeated movement, and the effect of clamping on minimum bending radius. Excessive pressure should not damage the cable sheath.

Selection should consider cable diameter range, expected mechanical load, mounting method, service frequency, vibration conditions and bending-radius requirements.

Components in this subcategory

Strain-relief clamps and cable retention systems for cabinets and machines.

Available parameters

Strain Relief

35 parameters
General3
Product Series

Commercial or technical designation of a manufacturer's product family sharing a common design and compatible characteristics.

Application

Range of tasks and systems for which the manufacturer recommends the component.

Intended Use

Primary function of the device and its intended use as defined by its design and the manufacturer's documentation.

Dimensions6
Widthmm

External horizontal dimension of the product between its outermost lateral points.

Heightmm

External vertical dimension of the product from its lowest to its highest point.

Depthmm

External distance between the foremost and rearmost surfaces of the product.

Lengthmm

External linear dimension of the product along its longitudinal direction or principal length axis.

Diametermm

Transverse dimension of a product or its circular element measured through the centre between opposite points of the circumference.

Net Weightkg

Mass of the product itself, excluding transport packaging, additional accessories, and external equipment.

Mounting and Installation8
Mounting Method

Method used to mechanically secure the product to a support, surface, or load-bearing structure.

Mounting Type

Installation arrangement permitted by the product design, such as wall-mounted, flush-mounted, floor-mounted, or another specified mounting type.

Orientation

Permissible spatial orientation of the component during installation and operation.

DIN Rail Mounting Supported

Indicates whether the design provides for mounting equipment on a DIN rail.

Number of Mounting Holes

Number of holes provided in the product for mechanical fixing.

Mounting Hole Diametermm

Diameter of the hole provided for a fixing element used when mounting the product.

Horizontal Mounting Hole Spacingmm

Distance between the centres of mounting holes in the horizontal direction.

Vertical Mounting Hole Spacingmm

Distance between the centres of mounting holes in the vertical direction.

Cable Entries4
Minimum Cable Diametermm

Minimum external diameter of a cable compatible with the specified entry system.

Maximum Cable Diametermm

Maximum external diameter of a cable compatible with the specified entry system.

Cable Retention ForceN

Manufacturer-declared axial cable retention or pull-out force of the cable termination or strain-relief system.

Strain Relief Type

Mechanical construction used to transfer cable tensile or bending loads away from electrical terminations.

Environmental Conditions10
IP Rating

Degree of enclosure protection against access to hazardous parts and ingress of solid objects and water, designated by the IP code.

IK Rating

Class of enclosure resistance to external mechanical impacts designated by the IK code.

Minimum Operating Temperature°C

Minimum ambient temperature at which normal operation of the product is permitted.

Maximum Operating Temperature°C

Maximum ambient temperature at which normal operation of the product is permitted.

Minimum Storage Temperature°C

Minimum ambient temperature permitted during storage of the product while not in operation.

Maximum Storage Temperature°C

Maximum ambient temperature permitted during storage of the product while not in operation.

Minimum Relative Humidity%

Minimum relative air humidity permitted for the declared operating or test condition.

Maximum Relative Humidity%

Maximum relative air humidity permitted for the declared operating or test condition.

Vibration Resistant

Indicates whether the product's resistance to vibration has been verified under the declared conditions.

Mechanical Shock Resistant

Indicates whether the product's resistance to short-duration mechanical shocks has been verified.

Standards and Compliance4
CE Marked

Indicates whether the CE marking is applied to the product where applicable.

RoHS Compliant

Indicates whether product compliance with applicable RoHS restrictions on hazardous substances has been declared.

IEC 60529 Compliant

Indicates whether the manufacturer declares product compliance with IEC 60529.

IEC 60068 Tested

Indicates whether the product has been tested according to applicable methods of the IEC 60068 series.