Electrical Component Parameter Reference

An open technical reference for electrical component types, their applications, and selection parameters.

This material is also available in PL and RU.

Device description

Undervoltage Release

Release that trips a device when control voltage falls below a defined level and prevents reclosing until voltage is restored.

An undervoltage release monitors whether sufficient voltage is available in the control circuit.

When voltage falls below the defined dropout level, the mechanism trips the device and normally prevents reclosing while the required voltage is absent.

It is used to protect equipment against unintended restart and to implement fail-safe control circuits.

Selection criteria include rated control voltage, dropout and reclose thresholds, supply type and mounting position on the host device.

Components in this subcategory

Undervoltage releases for breakers, switches and fail-safe control circuits.

Available parameters

Undervoltage Release

59 parameters
General3
Product Series

Commercial or technical designation of a manufacturer's product family sharing a common design and compatible characteristics.

Application

Range of tasks and systems for which the manufacturer recommends the component.

Intended Use

Primary function of the device and its intended use as defined by its design and the manufacturer's documentation.

Dimensions4
Widthmm

External horizontal dimension of the product between its outermost lateral points.

Heightmm

External vertical dimension of the product from its lowest to its highest point.

Depthmm

External distance between the foremost and rearmost surfaces of the product.

Net Weightkg

Mass of the product itself, excluding transport packaging, additional accessories, and external equipment.

Materials and Finish3
Material

Primary material from which the product is manufactured.

Color

Primary visually perceived colour of the product's external surface.

Surface Finish

Type of final surface finish of the product determining its appearance and service properties.

Mounting and Installation4
Mounting Type

Installation arrangement permitted by the product design, such as wall-mounted, flush-mounted, floor-mounted, or another specified mounting type.

Mounting Method

Method used to mechanically secure the product to a support, surface, or load-bearing structure.

Orientation

Permissible spatial orientation of the component during installation and operation.

Mounting Position on Device

Position of the accessory relative to the host switching or protective device, independent of the general installation orientation.

Electrical Parameters28
Control VoltageV

Voltage applied to the control circuit to perform the product's intended functions.

Minimum Coil Drop-Out Voltage Ratio%

Minimum declared drop-out voltage of the contactor coil expressed as a percentage of rated control voltage Uc, where a range is specified.

Control Voltage Type

Type of current used in the product's control circuit.

Maximum Coil Drop-Out Voltage Ratio%

Maximum declared drop-out voltage of the contactor coil expressed as a percentage of rated control voltage Uc.

Control FrequencyHz

Frequency of the alternating voltage or signal in the product's control circuit.

Minimum Coil Operating Voltage Ratio%

Minimum manufacturer-declared coil operating voltage expressed as a percentage of rated control voltage Uc.

Maximum Coil Operating Voltage Ratio%

Maximum manufacturer-declared coil operating voltage expressed as a percentage of rated control voltage Uc.

Coil Pull-In Apparent PowerVA

Apparent power consumed by an AC-operated control coil during pull-in or inrush.

Coil Holding Apparent PowerVA

Apparent power consumed by an AC-operated control coil in the sealed or holding state.

Coil Pull-In PowerW

Active or DC power consumed by the contactor control circuit during pull-in or inrush.

Coil Holding PowerW

Active or DC power consumed by the contactor control circuit in the sealed or holding state.

Coil Inrush CurrentA

Manufacturer-declared current drawn by the control coil during initial energization.

Coil Holding CurrentA

Manufacturer-declared current drawn by the control coil in the sealed or holding state.

Coil ResistanceΩ

Manufacturer-declared DC resistance of the relay coil at the stated reference temperature.

Nominal Coil PowerW

Nominal power consumption of the relay coil or electromagnetic drive at rated control voltage.

Nominal Coil CurrentA

Nominal current consumed by the relay coil at its rated control voltage.

Minimum Control Pulse Durationms

Minimum duration of a general toggle or step control pulse accepted by an impulse or bistable relay.

Maximum Control Pulse Durationms

Maximum duration of a control signal or pulse permitted by the relay manufacturer.

Rated Insulation VoltageV

Voltage with reference to which the product's insulation clearances and dielectric properties are specified.

Rated Impulse Withstand VoltagekV

Peak value of an impulse voltage of specified waveform that the product insulation must withstand without breakdown.

Dielectric Test VoltageV

Test voltage applied to verify the dielectric strength of the product insulation.

Conductor Connection Type

Conductor connection methods supported by the specified terminals or connection elements.

Minimum Conductor Cross-Sectionmm²

Minimum conductor cross-section permitted by the connection system within its general conductor-size range.

Maximum Conductor Cross-Sectionmm²

Maximum conductor cross-section permitted by the connection system within its general conductor-size range.

Terminal Tightening TorqueNm

Tightening torque specified by the manufacturer for a screw or bolted terminal connection.

Minimum Stripping Lengthmm

Minimum conductor stripping length specified by the manufacturer.

Maximum Stripping Lengthmm

Maximum conductor stripping length specified by the manufacturer.

Mechanical Endurancecycles

Declared number of mechanical operating cycles that the product can perform without electrical switching load.

Protection and Safety4
IP Rating

Degree of enclosure protection against access to hazardous parts and ingress of solid objects and water, designated by the IP code.

Protection Against Direct Contact

Method or level of protection of the user against direct contact with hazardous live parts.

Finger-Safe

Indicates whether the design prevents finger access to hazardous live parts in the intended condition.

Touch-Safe

Indicates whether the design provides protection against accidental contact with hazardous live parts.

Environmental Conditions5
Minimum Operating Temperature°C

Minimum ambient temperature at which normal operation of the product is permitted.

Maximum Operating Temperature°C

Maximum ambient temperature at which normal operation of the product is permitted.

Minimum Storage Temperature°C

Minimum ambient temperature permitted during storage of the product while not in operation.

Maximum Storage Temperature°C

Maximum ambient temperature permitted during storage of the product while not in operation.

Maximum Relative Humidity%

Maximum relative air humidity permitted for the declared operating or test condition.

Special Features1
Continuous Control Signal Permitted

Indicates that a continuous or prolonged control signal may be applied without violating the manufacturer-declared operating conditions.

Standards and Compliance7
CE Marked

Indicates whether the CE marking is applied to the product where applicable.

IEC 60947-5-1 Compliant

Compliance with applicable IEC 60947-5-1 requirements for control-circuit devices and switching elements.

UL Listed

Indicates whether the product has a declared UL Listed certification or recognition status.

CSA Certified

Indicates whether the product has a declared CSA certification or recognition status.

RoHS Compliant

Indicates whether product compliance with applicable RoHS restrictions on hazardous substances has been declared.

REACH Compliant

Indicates whether the manufacturer declares compliance of the product with applicable REACH Regulation requirements.

IEC 60947-1 Compliant

Indicates declared compliance of the product with the applicable general requirements of IEC 60947-1 for low-voltage switchgear and controlgear.