Lighting Load
Electrical luminaire or other lighting load described by power, photometric, control, and emergency-operating characteristics.
A lighting load represents an individual luminaire, light source, or integrated lighting device as an electrical consumer.
Electrical characteristics include active, apparent, and reactive power, power factor, duty type, and duty cycle.
Photometric characteristics include luminous efficacy, correlated colour temperature, colour rendering index, and beam angle.
Additional functions may include dimming and emergency lighting with its own declared autonomy time.
Selection and circuit design consider input power, starting behaviour, control method, protection requirements, IEC 60598-1, and applicable EU energy-labelling and ecodesign rules.
Lighting loads including luminaires and lighting devices for electrical-circuit calculations.
Lighting Load
General5
Commercial or technical designation of a manufacturer's product family sharing a common design and compatible characteristics.
Range of tasks and systems for which the manufacturer recommends the component.
Primary function of the device and its intended use as defined by its design and the manufacturer's documentation.
Permissible installation location of the product: indoors, outdoors, in a technical area, or as part of equipment.
Environmental conditions under which installation and operation of the product are permitted.
Dimensions4
External horizontal dimension of the product between its outermost lateral points.
External vertical dimension of the product from its lowest to its highest point.
External distance between the foremost and rearmost surfaces of the product.
Mass of the product itself, excluding transport packaging, additional accessories, and external equipment.
Capacity and Layout1
Number of installed or integrated light sources.
Materials and Finish4
Primary material from which the product is manufactured.
Grade, alloy, class, or technical designation of the product's primary material.
Primary visually perceived colour of the product's external surface.
Type of final surface finish of the product determining its appearance and service properties.
Mounting and Installation3
Installation arrangement permitted by the product design, such as wall-mounted, flush-mounted, floor-mounted, or another specified mounting type.
Method used to mechanically secure the product to a support, surface, or load-bearing structure.
Permissible spatial orientation of the component during installation and operation.
Electrical Parameters30
Type of electrical current for which the product's main supply circuit is intended.
Voltage value assigned to the product by the manufacturer for specified application conditions and characteristics.
Current assigned to the product by the manufacturer for the declared operating and thermal conditions.
AC frequency assigned to the product for normal operating conditions.
Number of phases of the electrical system for which the product is designed to be connected or used.
Configuration of live and neutral conductors of the electrical system supported by the product.
Rated active electrical power of the product declared by the manufacturer for specified operating conditions.
Manufacturer-declared rated electrical input power consumed by the product at the specified operating point.
Manufacturer-declared rated apparent power of the electrical load.
Manufacturer-declared rated reactive power of the electrical load where applicable.
Manufacturer-declared power factor of the load at the specified operating point.
Peak input current occurring during energization or startup of the device.
Manufacturer-declared duration associated with the specified input inrush current.
Electrical power consumed by the product itself in the declared normal operating mode.
Manufacturer-declared electrical power consumption while the product is energized but not actively switching the controlled load.
General operating duty of the electrical load, such as continuous, intermittent or cyclic.
Fraction of a repeating operating period during which the load is energized or actively operating.
Indicates whether a neutral conductor connection is required for the product to perform its intended electrical or electronic functions.
Indicates that connection to protective earth is required for the declared electrical safety or operating conditions.
Indicates whether a supply cable is permanently connected to the product or supplied with it.
Length of the supply cable supplied with the product or permanently connected to it.
Manufacturer-declared standard or type designation of the supply cable fitted to or supplied with the product.
Indicates whether the supply cable can be replaced in accordance with the procedure specified by the manufacturer.
Type or system of mains plug integrated into the product or supplied as part of it.
Conductor connection methods supported by the specified terminals or connection elements.
Minimum conductor cross-section permitted by the connection system within its general conductor-size range.
Maximum conductor cross-section permitted by the connection system within its general conductor-size range.
Tightening torque specified by the manufacturer for a screw or bolted terminal connection.
Lighting technologies or lamp-load types for which the switching rating is declared.
Declared energy-efficiency class according to the applicable product labelling scheme.
Protection and Safety9
Degree of enclosure protection against access to hazardous parts and ingress of solid objects and water, designated by the IP code.
Class of enclosure resistance to external mechanical impacts designated by the IK code.
Class of protection against electric shock determined by the product design and protective connection method.
Indicates that the manufacturer or design specification recommends supplying the load from a dedicated final circuit.
Manufacturer- or design-recommended rated current of the upstream protective device.
Recommended upstream overcurrent or combined protective-device technology for the load.
Recommended instantaneous/time-current characteristic of an upstream circuit breaker where declared.
Indicates that residual-current protection is explicitly required by the product or circuit specification.
Recommended residual-current device sensitivity technology such as AC, A, F or B where explicitly specified.
Environmental Conditions5
Minimum ambient temperature at which normal operation of the product is permitted.
Maximum ambient temperature at which normal operation of the product is permitted.
Minimum ambient temperature permitted during storage of the product while not in operation.
Maximum ambient temperature permitted during storage of the product while not in operation.
Maximum relative air humidity permitted for the declared operating or test condition.
Included Equipment8
Manufacturer-declared total luminous flux of the visual signaling output.
Manufacturer-declared luminous intensity of the visual signaling output.
Ratio of emitted luminous flux to electrical input power.
Declared correlated colour temperature of the emitted light.
Declared general colour rendering index of the light source or luminaire.
Declared beam angle of the luminaire or light source.
Primary light-generation technology used by the visual indicator or signaling device.
Manufacturer-declared operating lifetime of the light source under specified conditions.
Special Features5
Indicates whether the light-generating element can be replaced according to the manufacturer instructions.
Indicates that the lighting load supports controlled dimming.
Electrical or communication methods supported for dimming the lighting load.
Indicates that the lighting product includes an emergency-lighting operating mode.
Declared autonomous operating duration in emergency mode.
Standards and Compliance7
Indicates whether the CE marking is applied to the product where applicable.
Indicates whether product compliance with applicable RoHS restrictions on hazardous substances has been declared.
Indicates whether the manufacturer declares compliance of the product with applicable REACH Regulation requirements.
Indicates whether the product falls within the scope of WEEE requirements for waste electrical and electronic equipment.
Manufacturer-declared compliance with IEC 60598-1 general requirements and tests for luminaires.
Indicates that the product is subject to an applicable EU energy-labelling scheme.
Indicates that the product is subject to applicable EU ecodesign requirements.