TRASA3 Knowledge Base

Electrical Component Parameter Reference

An open technical reference for electrical component types, their applications, and selection parameters.

This material is also available in PL and RU.

Device description

Proportional Valve

Electrically controlled valve providing continuous flow or pressure regulation proportional to a command signal.

A proportional valve differs from a conventional on/off valve by continuously varying the position of its regulating element.

Control may use an analogue voltage or current signal, PWM, or a digital interface.

Operating characteristics depend on medium, number of ways and positions, port size, pressure range, and nominal flow.

Hysteresis and repeatability describe regulation accuracy and reproducibility.

Selection considers command-signal type, required flow or pressure range, dynamics, working medium, coil, and control-system requirements.

Components in this subcategory

Proportional valves for regulated pneumatic and hydraulic systems.

Available parameters

Proportional Valve

50 parameters
General3
Product Series

Commercial or technical designation of a manufacturer's product family sharing a common design and compatible characteristics.

Application

Range of tasks and systems for which the manufacturer recommends the component.

Intended Use

Primary function of the device and its intended use as defined by its design and the manufacturer's documentation.

Dimensions6
Widthmm

External horizontal dimension of the product between its outermost lateral points.

Heightmm

External vertical dimension of the product from its lowest to its highest point.

Depthmm

External distance between the foremost and rearmost surfaces of the product.

Lengthmm

External linear dimension of the product along its longitudinal direction or principal length axis.

Diametermm

Transverse dimension of a product or its circular element measured through the centre between opposite points of the circumference.

Net Weightkg

Mass of the product itself, excluding transport packaging, additional accessories, and external equipment.

Mounting and Installation8
Mounting Method

Method used to mechanically secure the product to a support, surface, or load-bearing structure.

Mounting Type

Installation arrangement permitted by the product design, such as wall-mounted, flush-mounted, floor-mounted, or another specified mounting type.

Orientation

Permissible spatial orientation of the component during installation and operation.

DIN Rail Mounting Supported

Indicates whether the design provides for mounting equipment on a DIN rail.

Number of Mounting Holes

Number of holes provided in the product for mechanical fixing.

Mounting Hole Diametermm

Diameter of the hole provided for a fixing element used when mounting the product.

Horizontal Mounting Hole Spacingmm

Distance between the centres of mounting holes in the horizontal direction.

Vertical Mounting Hole Spacingmm

Distance between the centres of mounting holes in the vertical direction.

Electrical Parameters8
Rated VoltageV

Voltage value assigned to the product by the manufacturer for specified application conditions and characteristics.

Rated CurrentA

Current assigned to the product by the manufacturer for the declared operating and thermal conditions.

Nominal Coil PowerW

Nominal power consumption of the relay coil or electromagnetic drive at rated control voltage.

Rated PowerW

Rated active electrical power of the product declared by the manufacturer for specified operating conditions.

Coil Duty Type

Permitted energization duty of the electromagnetic coil.

Rated FrequencyHz

AC frequency assigned to the product for normal operating conditions.

Proportional Valve Command Signal Types

Electrical command/setpoint signal types accepted by the proportional valve or valve electronics.

Power ConsumptionW

Electrical power consumed by the product itself in the declared normal operating mode.

Environmental Conditions10
IP Rating

Degree of enclosure protection against access to hazardous parts and ingress of solid objects and water, designated by the IP code.

IK Rating

Class of enclosure resistance to external mechanical impacts designated by the IK code.

Minimum Operating Temperature°C

Minimum ambient temperature at which normal operation of the product is permitted.

Maximum Operating Temperature°C

Maximum ambient temperature at which normal operation of the product is permitted.

Minimum Storage Temperature°C

Minimum ambient temperature permitted during storage of the product while not in operation.

Maximum Storage Temperature°C

Maximum ambient temperature permitted during storage of the product while not in operation.

Minimum Relative Humidity%

Minimum relative air humidity permitted for the declared operating or test condition.

Maximum Relative Humidity%

Maximum relative air humidity permitted for the declared operating or test condition.

Vibration Resistant

Indicates whether the product's resistance to vibration has been verified under the declared conditions.

Mechanical Shock Resistant

Indicates whether the product's resistance to short-duration mechanical shocks has been verified.

Special Features11
Solenoid Valve Medium

Primary fluid/gas medium controlled by the solenoid valve.

Valve Way Count

Number of flow ports/ways represented in the valve function, for example 3/2 or 5/2.

Valve Position Count

Number of stable spool/valve positions.

Valve Port Size

Fluid port thread, tube or connection size.

Minimum Valve Operating PressurekPa

Minimum operating medium pressure.

Maximum Valve Operating PressurekPa

Maximum operating medium pressure.

Valve Nominal FlowL/min

Manufacturer-declared nominal flow rate at the stated pressure conditions.

Valve Hysteresis%

Difference in valve output/flow for increasing versus decreasing command at the same command value.

Valve Repeatability%

Manufacturer-declared repeatability of valve output or position for repeated command conditions.

Manual Override Present

Indicates that the contactor provides a local manual override mechanism in addition to electrical coil operation.

Response Timens

Manufacturer-declared response time of the relevant protective function of the product to a surge impulse.

Standards and Compliance4
CE Marked

Indicates whether the CE marking is applied to the product where applicable.

RoHS Compliant

Indicates whether product compliance with applicable RoHS restrictions on hazardous substances has been declared.

IEC 60529 Compliant

Indicates whether the manufacturer declares product compliance with IEC 60529.

IEC 60068 Tested

Indicates whether the product has been tested according to applicable methods of the IEC 60068 series.